 Holeless, roped hydraulic
elevator with Elevette or Elevette 2100 car
Specifications
TS/Technical Support
Furnish and install Inclinator Company of America to travel a distance
of _____ feet and _____ inches, serving _____ stops and _____ door openings. (9" min
pit - 8'- 0" min overhead)
The shall have a capacity of 750 pounds and a speed of 30 feet per minute.
Electric Requirements - operates on available power supply, such as 208,230
volts 60 Hz single phase alternating current or 208,220,440 volts three phase, 60 Hz. 50
Hz equipment available for export. Control voltage is 24 volts.
For operation on _____ volts _____ phase _____ Hz.
The lifting system shall consist of a high quality hydraulic jack,
hydraulic pump and 2-3/8" x 8 x 19 improved plow steel cables. Monorail and trolley
shall be provided along with type "A" safties. The system shall have passenger
controlled and manual lowering devices and pit and car top stop switches.
Power unit shall be located at ______________________ (specify which
floor).
The car shall be _____ inches in depth (distance out from rail) and
_____ inches in width. Elevette car height 6' -7' or 7'0". Elevette 2100 7'0"
overall. (max D dimension 36"-max W dimen. 52")
Choose one of the following car descriptions.
Elevette 2100 car shall be constructed of _____ 3/8"
veneer panels, _____ plastic laminate panels, _____ painted veneer, acrylic mirror or
clear or tinted acrylic, _____ unfinished veneer panels. (specify color where required
_____.)
Elevette car shall be constructed of _____ auto steel panels,
_____ plastic laminate covered panels, _____ all hardwood car (give wood choice) _____
raised panel wood car. Color card or wood sample will be furnished manufacturer for solid
or grained finish _____. Other type _____ (give details).
The car shall be equipped with _____ collapsible floating safety
gates (see car code arrangements lower left), and one wooden hand rail. Swing type shaft
doors shall be electrically and mechanically interlocked.
Advise if necessary for gate to reject 3" ball. Yes ____ No
____
Controls shall be momentary pressure, automatic type, with call
buttons at each floor and a bank of car control buttons with a stop button and light
switch.
Terminal and overrun limit switches shall be furnished along with
slack rope and low pressure switches, and an anticreep device.
Car lighting can be swivel, surface mounted fluorescent or full
fluorescent ceiling or down lights.
Optional Equipment-Gate safety bar, gate open alarm, brass handrail,
folding shelf, key switch operation, telephone cabinet, leg extension pan, in-use and
arrival lights, lighted buttons, special car heights and construction.


|