| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
ITW Buildex Buildex Products Catalog Teks - Page 20
| TEKS® |
EXTERIOR RIGID INSULATION FASTENERS |
Product Report No.81109 |
Selector Guide
  |
Part
No. |
Description |
Head
Style |
Drill
Point |
Drill
& Tap Capacity |
Max.
Material Attachment |
Applications |
| 1034000 1036000
1038000
1040000 |
Maxiseal® 12-14x1-7/8''
12-14x2-3/8''
12-14x3-1/4''
12-14 x 4'' |
HWH HWH
HWH
HWH |
#3 #3
#3
#3 |
.036-.210 .036-.210
.036-.210
.036-.210 |
3/4'' to 1'' 1-1/8'' to 1-1/2''
1-5/8'' to 2-3/8''
2-1/8'' to 3'' |
- Roof and wall panel over rigid insulation to steel framing.
- Roof panel over spacer block and insulation to eave
purlin.
|
| 1169200 1170200
1171200
1172200 |
Scots® 12-14x1-7/8''
12-14x2-3/8''
12-14x3-1/4''
12-14 x 4'' |
HWH HWH
HWH
HWH |
#3 #3
#3
#3 |
.036-.210 .036-.210
.036-.210
.036-.210 |
3/4'' to 1'' 1-1/8'' to 1-1/2''
1-5/8'' to 2-3/8''
2-1/8'' to 3'' |
Performance Data
| PULLOUT
VALUES (average lbs. ultimate) |
| Fastener |
Steel Gauge
|
| Dia |
Pt. |
26 |
24 |
22 |
20 |
18 |
16 |
14 |
12 |
3/16 |
| 12 |
3 |
142 |
211 |
289 |
341 |
551 |
757 |
1063 |
1631 |
2998 |
| FASTENER
VALUES |
| Fastener (dia-tpi) |
Tensile (lbs.min) |
Shear (avg.lbs.ult.) |
Torque (min.in.lbs) |
| 12-14 |
2778 |
2000 |
90 |
| SHEET
STEEL GAUGES |
| Gauge No. |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
26 |
| Decimal Equivalent |
.105'' |
.75'' |
.060'' |
.48'' |
.036'' |
.030'' |
.024'' |
.018'' |
| SHEAR
VALUES (average lbs. ultimate) |
| Fastener |
Steel Gauge
(average lbs. ultimate) |
| Dia |
Pt. |
26 |
24 |
22 |
20 |
18 |
16 |
14 |
12 |
| 12 |
3 |
|
|
|
769 |
1358 |
1620 |
1970 |
1986 |
The values listed are ultimate averages achieved under
laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety
factors should be applied to these values for design purposes.
Installation Guidelines
 |
A standard screwgun with a depth
sensitive nosepiece should be used to install teks. For optimal fastener performance, thru
screwgun should be a minimum of 4 amps and have a RPM range of 0-2000. |
 |
Adjust the screwgun nose piece
to properly seat the fastener. |
 |
New magnetic sockets must be
correctly set before use. Remove clip build up as needed. |
 |
Overdriving may result in
torsional failure of the fastener or stripout of the substrate. |
 |
The fastener must penetrate
beyond the metal structure a minimum of 3 pitches of thread. |

 |
Teks®,
Scots®, Maxiseal®,
Climaseal® and Building Ideas the
Work are trademarks of ITW Buildex and Illinois Tool Works Inc. |
BUILDING IDEAS THAT WORK 1349 West
Mawr Avenue
Itasca, Illinois 60143
630/595-3500 FAX: 630/595-3549
www.itwbuildex.com |
©1999
Illinois Tool Works, Inc. |
|
Copyright © 19962008 AECinfo.com
|
|