| SCOTS®
TAPCON® |
CONCRETE ANCHOR |
Product Report No.81118 |
Selector Guide
| Fastener Description |
Fastener Part Number |
Standard Box Qty. |
Standard Carton Quantity |
Carbide Drill (Straight Shank) |
Bit Part No |
Finish |
Available Head paint |
1/4 x 1-3/4''
Fully Threaded |
3358407 |
100 |
1000 pcs |
3/16x3-1/2 |
3098910 |
Silver Climaseal® |
White or Bronze |
1/4 x 2-1/4''
Fully Threaded |
3359407 |
100 |
1000 pcs |
3/16x4-1/2 |
3099910 |
Optional Items: Original Tapcon Carbide Drill Bits,
Condrive Tools and Installation Sockets
| Carbide Drill Bits (Straight
Shank) |
Bit Part No. |
Standard Tube Qty. |
| 3/16 x 5-1/2'' |
3100910 |
10 pcs |
| 3/16 x 6-1/2'' |
3102910 |
10 pcs |
| 3/16 x 7-1/2'' |
3206910 |
10 pcs |
| Carbide Drill Bits (SDS Shank) |
Bit Part No. |
Standard Tube Qty. |
| 3/16 x 7-1/2'' |
3101910 |
1 pcs |
| Condrive® 500 |
Part No. 3379910 |
| Condrive® 1000 |
Part No. 3103910 |
| Condrive® 2000 |
Part No. 3119910 |
Performance Data
PULLOUT IN CONCRETE (3145 PSI )
| Anchor
Diameter |
Depth of
Embedment in Solid Material (inches) |
| 1'' |
1-1/4'' |
1-1/2'' |
1-3/4'' |
| 1/4'' |
718 lbs. |
1138 lbs. |
1537 lbs. |
1860 lbs. |
Test Number CH3932/Pittsburgh Testing Laboratories
PULLOUT IN HOLLOW BLOCK (3145 PSI)
| Anchor
Diameter |
Depth of
Embedment in Solid Material (inches) |
| 1'' |
1-1/4'' |
1-1/2'' |
1-3/4'' |
| 1/4'' |
406 lbs. |
615 lbs. |
851 lbs. |
984 lbs. |
Test Number CH3748/Pittsburgh Testing Laboratories
SHEAR STRENGTH
| Anchor Diameter |
Anchor Embedment |
Shear Strength 3145 PSI
Hard Rock Concrete |
Shear Strength
Lightweight Hollow block |
| 1/4'' |
1-1/4'' |
1604 lbs. |
1058 lbs. |
Test Number CH3932/Pittsburgh Testing Laboratories
Note: Indicated pull-out and shear failure
values were obtained in tests witnessed by Pittsburgh Testing Laboratory personnel.
Designated holding power depends on the quality of the masonry material, depth of
embedment and proper hole size. These figures are offered only u as a guide and are not
guaranteed in any way by Illinois Tool Works Inc. The figures indicate average ultimate
pull-out and shear failure values. A safety factor of 4:1 or 25% of ultimate pull out
value is generally accepted as a safe working load. However, reference should always
be made to applicable codes for the specific safe working ratio. All values are based on
close tolerance holes drilled with Buildex Tapcon®
carbide drill bits. Performance of the Tapocon anchor may vary in extremely hard concrete
aggregates. Consult your Buildex representative for further information.
As in the case with all applications, Buildex can only
suggest typical fasteners for typical applications and that the connection design's in the
sole responsibility of the Building Design Engineer, Architect or otherwise responsible
person charged with the design of the connection. For further product information, please
contact the nearest Authorized Buildex Distributor or the Buildex Technical Service
Department at 1-800-323-0720.
 |
Scots®,
Tapcon®, Maxi-Set Tapcon® , Condrive®
500,Condrive® 1000,Condrive® 2000, Climaseal®,
Driv-Tru and Building Ideas the Work are trademarks of ITW Buildex and
Illinois Tool Works Inc. |
BUILDING IDEAS THAT WORK 1349 West
Bryn Mawr Avenue
Itasca, Illinois 60143
630/595-3500 FAX: 630/595-3549
www.itwbuildex.com |
©1999