SCOTS®TRUGRIP™ METAL-TO-WOOD APPLICATIONS Product Report No. 90704

Selector Guide

build51a.jpg (14630 bytes)

 

Part No. Description Drill Point Drill & Tap Capacity Max. Material Attachment Common
Applications
1687000

1655000

1658000

1651000

1691000

9-15 x 1''

9-15x1-1/2''

9-15 x 2''

9-15x2-1/2''

12-14 x 3/4''

Gimlet

Gimlet

Gimlet

Gimlet

Gimlet

.012-.048

.012-.048

.012-.048

.012-.048

.012-.048

0-.250

0-.750

.500-1.250

1.000-1.750

    ------

  Roof and   wall panel      to wood       structure

• Panel over  insulation      to wood       structure

• Stiching of  roofand wall panel


Performance Data

PULLOUT VALUES IN STEEL (average lbs. ultimate)
Fastener Steel Gauge
Dia 26 24 22 20 18
9 171 252 329 401 634
12 199 271 360 426 656

 

PULLOUT VALUES IN WOOD (average lbs. ultimate)
Fastener Embedment 2'' x 4'' (SYP)
Dia 1/2'' 3/4'' 1'' 1-1/4'' 1-1/2''
9 198 328 571 728 872
12 210 335      

 

FASTENER VALUES 
Fastener (dia-tpi) Tensile (lbs.min) Shear (avg.lbs.ult.) Torque (min.in.lbs)
9 1800 1200 50
12 2778 2000 90

 

PULLOVER VALUES (average lbs. ultimate)
Fastener Steel Gauge
Dia    26 24 22 20 18
9 Washered 515 674 875 1100 1627
12 Washered 587 744 915 993 1246

 

SHEET STEEL GAUGES
Gauge No. Decimal Equivalent
18 .048''
20 .036''
22 .030''
24 .024''
26 .018''
28 .015''
30 .012''

The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes.


Installation Guidelines

A standard screwgun with a depth sensitive nosepiece should be used to install Scots® TruGrip. For optimal fastener performance, the screwgun should be a minimum of 4 amps and have a RPM range of 0-2000.
Adjust the screwgun nose piece to properly seat the fastener.
New magnetic sockets must be correctly set before use. Remove clip build up as needed.
Overdriving may result in torsional failure of the fastener or stripout of the substrate.
The fastener must penetrate beyond the metal structure a  minimum of 3 pitches of thread.


Scots®,TruGrip™ GT, Climaseal® and Building Ideas the Work™ are trademarks of ITW Buildex and Illinois Tool Works Inc.

BUILDING IDEAS THAT WORK™

1349 West Bryn Mawr Avenue
Itasca, Illinois 60143
630/595-3500 FAX: 630/595-3549
www.itwbuildex.com

©1999 Illinois Tool Works, Inc.