architecture - engineering - construction
AECinfo.com
Printable version Bookmark this page Notify a colleague or friend about this page Bookmark and Share
  ITW Buildex   Flashings  

Dektite and Retrofit Dektite

   

Flashings

DEKTITE® PIPE FLASHING Product Report No.81113

Selector Guide

DEKTITE® FLASHING GUIDE

Part No. Description Pipe Outside Diameter Dektite Base Diameter Detite Height
4001910 Mini 1/4''-1-1/8'' 3-1/2'' 1-3/4''
4003910 1 1/4''-2'' 4-3/4'' 3''
4004910 2 1-3/4''-3-/14'' 6-1/4'' 4''
4009910

4035910

3

#3 silicone

1/4''-4'' 7-3/4'' 4''
4011910 4 3''-6'' 9-1/4'' 5''
4016910

4036910

5

#5 silicone

4''-7'' 10-3/4'' 5''
4018910 6 5''-9'' 12-1/2'' 6''
4020910 7 6''-1'' 14-1/2'' 6''
4025910

4038910

8

#8 silicone

7''-13'' 16-1/2'' 6''
4028910

4039910

9

#9 silicone

10''-18'' 25-3/8'' 8''
4000910 Diverter 16''-24'' 39-1/2'' x 35'' 9''

Note: When used on roofs where pitch is steeper than 20 degrees, or when used on deep ribbed profile roof panel (1-1/2'' deep corrugation or more), consider using next larger size Dektite that will accommodate the same pipe diameter. Recommended Sealant: Chemseco Sikaflex ® sealant, part number 4040910

Retrofit Dektite® Selector Guide

Part Number Dektite Size Number Pipe Outside Diameter Dektite Base Diameter Dektite Height
4029210 801 3/4'' - 2-3/4'' 6-3/10'' 3-1/2''
4030910 802 2'' - 7-1/4'' 10-3/4'' 5-3/5''
4031910 803 3-1/4'' - 10'' 14-1/2'' 5-4/5''

Performance Data

ASTM Method Test Description Specification Test Results
D412 Tensile Strength (min.psi rating) 1450 psi. min 1537 psi
D412 Ultimate Elongation(%) 350 min. 535
D1171 Resistance to Ozone Min. rating 100 (no cracks) Passed
D673 Heat Aging - 70 hrs. at 212° F
  • Change in Hardness (points)
± 15 max. +8
  • Change in Tensile Strength (%)
± 30 max. -4.7
  • Change in Elongation (%)
± 50 max. -26

 

ASTM Method Test Description Specification Test Results
D2137 Low Temperature Brightness 3 mins. at -40°F Non-brittle Passed
D624 Tear Resistance Die C(min) per inch of width min. 125 pounds per inch of width 130 pounds
U.L. 94 Flame Resistance U.L.94 H.B. Passed

STEP 1 : Begin cutting opposite of the mechanical locking joiner. Cut through the joiner with tin snips. STEP 2 : Wrap Retrofit Dektite® around the pipe. Engage the top section of the joiner first, then proceed down until joiner is completely engaged. STEP 3 : Crimp joiner tightly, starting at the top by squeezing joiner ''finger's' with pliers.
STEP 4 : Apply sealant to the underside of the ribbed aluminum base. Press Retrofit Dektite® against contours of the panel configuration. STEP 5 : Apply Retrofit Dektite® to the panel with SCOTS® self-drilling screws. Screws should be spaced as necessary to avoid gaps between the base and the panel. STEP 6 :  Apply additional sealant around the top of the Dektite® and along the mechanical locking joiner seam.

Recommended Sealant: Chemseco Sikaflex sealant, part number 4040910.


Dektite® Retrofit Dektite®, SCOTS®  and Building Ideas the Work™ are trademarks of ITW Buildex and Illinois Tool Works Inc. Sikaflex®  is registered trademark of Chemseco Corporation.

BUILDING IDEAS THAT WORK™

1349 West   Bryn Mawr Avenue
Itasca, Illinois 60143
630/595-3500 FAX: 630/595-3549
www.itwbuildex.com

©1999 Illinois Tool Works, Inc.



Request for Information / Request a Catalog from ITW Buildex
 
 
 
To request more information from ITW Buildex, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 