HEXTRA PLUS™  PRE-ASSEMBLED STEEL AND WOOD DECK FASTENING

PRODUCT REPORT NO. 90703


Installation Guidelines

An ITW Buildex AccuFast installation tool, or a standard screwgun with a disengaging clutch should be used to install the assembled fasteners. The screwgun should have a range of 1,800-2,500 RPM. The screwgun should also have a minimum current rating of 4 amps.
Fasteners should be spaced using a pattern specified by the insulation or roof cover manufacturer.
The nosepiece of the screwgun should be adjusted so the clutch disengages when the fastener is fully and properly seated.
The fastener must penetrate the metal deck a minimum of 3/4" for Factory Mutual System Approval.
The fastener is fully seated when the head is tight against the metal plate. The fastener should not be overdriven as to cause the plate surface to deflect more than 1/16".
Overdriven fasteners will significantly reduce fastener and plate performance and/or strip the deck. Underdriven fasteners will not distribute the load over the plate properly.

ITW Buildex Hextra

Standard Thread Modified Buttress Thread X-Point

 

Selector Guide

*HEXTRA™ PLUS
*ROOFGRIP PLUS

          perfo05bb.jpg (8772 bytes)

Hextra or Roofgrip fastener pre-assembled with 3" round metal plates for insulation attachment to 18-26 gauge steel and wood.

Hextra
Plus Part No.
Roofgrip
Plus Part
No.
Length Usable Thread Length Box
Weight
(lbs.)
Box Qty.
6469003 6515003* 2-1/4" Full 13.5 250
6470003 6516003* 2-7/8" Full 14.6 250
6471003 6517003* 3-1/4" 2-3/4" 15.1 250
6472003 6518003* 3-3/4" 2-3/4" 15.8 250
6473003 6519003* 4-3/8" 3-1/2" 16.7 250
6474003 6520003* 5" 3-3/4" 17.8 250
6475003 6521003* 6" 3-3/4" 19.1 250
6476003 6522003 7" 3-3/4" 20.7 250
6477003 6523003* 8" 3-3/4" 22.1 250

*Available with PSpex (103) long life protective coating.

Ultimate Tensile Load - 2562 lbs.
Ultimate Shear Load -
1229 lbs.

 

Pullout Values

In Metal

Gauge 18 20 22 24 26
Lbs. 894 656 488 425 294

In Plywood

Thickness 3/8"   1/2"   3/4"
Lbs. 200   326   544

In Wood Plank

Depth 1"   1-1/4"   1-1/2"
Lbs. 784   1,084   1,292

NOTE: Test results were obtained under laboratory controlled conditions. Appropriate safety factors should be applied to these ultimate values.

perfo08b.jpg (6743 bytes)

For engineering assistance or the name of your nearest ITW Buildex distributor call toll-free 800 BUILDEX (800-284-5339).


BUILDING IDEAS THAT WORK™

1349 West Bryn Mawr Avenue

Itasca, IIIinois 60143

630/595-3500 FAX: 630/595-3569

Hextra Plus, Roofgrip Plus™, Climaseal™ , AccuFast™ and Building Ideas That Work™  are trademarks of ITW Buildex and Illinois Tool Work, Inc.

©1999 Illinois Tool Works, Inc.



Request for Information / Request a Catalog from ITW Buildex
 
 
 
To request more information from ITW Buildex, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.