architecture - engineering - construction
AECinfo.com
Printable version Bookmark this page Notify a colleague or friend about this page Bookmark and Share
  ITW Buildex   Roofing  

#15 Roofgrip page 2

   

Roofing

#15 ROOFGRIP™ STEEL, WOOD AND STRUCTURAL CONCRETE DECK FASTENING

PRODUCT REPORT NO. 90704


Installation Guidelines

An Accudrive XL PLUS™ or a standard screwgun with a disengaging clutch should be used to install #15 Roofgrip. The screwgun should have a range of 1,800-2,500 RPM. The screwgun should also have a minimum current rating of 4 amps.
The nosepiece of the screwgun should be adjusted so the clutch disengages when the fastener is fully and properly seated.
Fasteners should be spaced using a pattern specified by the insulation or roof cover manufacturer.
The fastener must penetrate the metal deck a minimum of 3/4".
The fastener is fully seated when the head is tight against the metal plate, or snaps into the GearLok locking plastic plate. The fastener should not be overdriven as to cause the plate surface to deflect more than 1/16".
Overdriven fasteners will significantly reduce fastener and plate performance and/or strip the deck. Underdriven fasteners will not distribute the load over the plate properly.

Note: For structural concrete applications when using #15 Roofgrip, the following additional guidelines should be adhered to:

Pre-drill a 7/32" ANSI pilot hole in the concrete using a hammerdrill or rotary hammer.
Hole should be at least 1/2" deeper than the required embedment.
Seat #15 Roofgrip fasteners using a standard variable speed screwgun or hammerdrill.
Minimum required embedment in concrete is 1".
Always use a rotary hammer when drilling hollow block.

 

Selector Guide - Metal, Wood And Structural Concrete
Part No. Spex Length Usable Thread
Length
Box Quantity Wt.
(lbs.)
*BKT6610006 1-1/4" Full 1,000 12.4
*BKT6611006 2" Full 1,000 18.8
*BKT6612006 3" Full 1,000 28.7
*BKT6613006 4" 2-3/4" 1,000 38.0
*BKT6614006 5" 3-3/4" 1,000 47.2
*BKT6615006 6" 3-3/4" 500 28.8
*BKT6616006 7" 3-3/4" 500 32.9
*BKT6617006 8" 3-3/4" 500 37.5
*6618106 10" 3-3/4"    
*6619106 12" 3-3/4"    
*6620106 14" 3-3/4"    
*6657106 16" 3-3/4"    

*Available with silver Climaseal® (506) long life protective coating.

 

Pullout Values

In Metal
Gauge 18 20 22 24 26
Lbs. 1323 928 690 586 403
In Plywood
Thickness   3/8" 1/2"   3/4"
Lbs.   342 499   804
In Wood Plank
Depth   1" 1-1/4"   1-1/2"
Lbs.   747 1,128   1,140
Pullout Values
In Concrete (3750 psi, with 7/32" dia pilot hole.)
Depth   1" 1-1/4" 1-1/2"  
Lbs.   1009 1364 1870  
Ultimate Tensile Load - 4144 lbs.
Ultimate Shear Load - 1957 lbs.

NOTE: Test results were obtained under laboratory controlled conditions. Appropriate safety factors should be applied to these ultimate values. Report No. 1216.

perfo08b.jpg (6743 bytes)

For engineering assistance or the name of your nearest ITW Buildex distributor call toll-free 1- 800 BUILDEX (800-284-5339).


BUILDING IDEAS THAT WORK™

1349 West Bryn Mawr Avenue
Itasca, IIIinois 60143 630/595-3500 FAX: 630/595-3549

GearLok, Roofgrip, Spex,  Accudrive XL PLUS™ and Building Ideas That Work™ are trademarks of ITW Buildex and IIIinois Tool Works Inc.
©1999 IIIinois Tool Works, Inc.