| Heavy Duty Surface Bolts 
454, 360 U.S. Pat No. 4,021,063. Pat in Canada 1979. 0454
U.S. Pat No. 4, 060,266.361 U.S. Pat, No.4,198,082. Pat. No. in Canada 1982.
- 361 features tamper-resistant mounting. Universal top strike
permits use of bolts with inswinging and outswinging doors
- 360 for flush labeled metal fire doors
- 360 and 0454 are tamper resistant and accept padlock (not
included) with max. 3/8" dia. shackle; min. 1-3/4" shackle opening height
- Rod of 453, 454 and 0454 is 1/4" x 3/4"
- 454 available in 28" and 44" lengths for hurricane
force winds
- Rod of 360 is 3/4" x 3/4"
- Width of 360, 453, 454 and 0454 is 2-1/32"
- Width of 361 is 1"
- 453, 454 and 0454 are available with mortise, rim and
universal strikes
- 454 features jimmy resistant design
- 361 and 360 are available with mortise and universal strikes
- Lengths over 12" are not UL Listed
| Prod. No. |
Length |
Proj. |
Throw |
Finishes |
| 360 |
12", 24" |
2-1/16" |
1-1/4" |
F2C |
| 361 |
8" |
1-5/8" |
1" |
F2C-3-10-10B-26D |
| 453 |
8", 12", 18", 24" |
1-5/16" |
1-3/16" |
F2C-10-26D |
| 454 |
5"
8"
12" |
1-5/16"
1-5/16"
1-5/16" |
1-3/16"
1-3/16"
1-3/16" |
F2C-4-10-26D
F2C*-10-10B-26D
F2C-10-26D |
| 0454 |
5", 8" |
1-5/16" |
1-3/16" |
F2C-26D |
Extension Flush Bolts

For use on installations not requiring UL label
- Extruded brass or aluminum plate, aluminum slide and bolt
head
- Standard length of rod is 12". 6" length available
on special order.
- 458-1/2" fits standard A.N.S.I. A 115.4 door and frame
prep.
- Strike included
| Prod.No. |
Rod Backset |
Bolt Head |
Throw |
Finishes |
| 256 |
5/8" |
1/2" sq. |
3/4" |
B3-4-10-10B-26-26D |
| 257,258, C258 |
5/8" |
1/2" sq. |
3/4" |
B3-4-10-10B-26-26D |
| 457-1/2 |
3/4" |
1/2" sq. |
3/4" |
B3-4-10-10B-26-26D |
| 458-1/2 |
3/4" |
1/2" rd. |
3/4" |
B3-9-10-10B-19-26-26D |
| 0458-1/2 |
3/4" |
1/2" rd. |
3/4" |
B3-26D |
C = Convex Face
UL Listed Seff-Latching Flush Bolts

For use as top and bottom flush bolts on the inactive leaf
of pair of coordinated doors where the inactive leaf is not required for exit purposes.
- Architecturally finished bras cover plate permits finish
changes in stock or at job site.
- Epoxy coated single lip wear plates wrap around 1-1/4"
active leaf, supplied with shims to compensate for door gap in excess of specified bolt
installation dimensions.
- 356 is for labeled wood covered composite fire doors, not
exceeding 1-1/2 hr. fire rating and 8 ft. in height.
- 357 is for labeled hollow metal fire doors, not exceeding 9
ft. in height, and for steel-covered composite fire doors not exceeding 8 ft. in height,
both having a maximum rating of 3 hours.
- 357 fits A.N.S.I. A115.4 door prep for manual bolts and is
spring actuated, manually retracted.
- Tested under UL supervision for a minimum of 100,000 cycles
- Bolts remain deadlocked when active leaf is closed providing
security and fire protection.
- Adjustable projection of bolt head for undercut doors
- Designed and UL Listed for 1-3/4" thick labeled doors
- Doors must be equipped with a coordinator.
- Non-handed
- Strike included
- Both are available in B3-9-10-10B-26-26D finishes.
- Top Strike - A.N.S.I.A115.4 modified for strike lip
| Prod.No. |
Backset |
Bolt Heads |
Throw |
Door Thickness |
Flat Floor Strike |
| 356 |
3/4" |
1/2" x 9/16" |
3/4" |
1-3/4" |
2-1/4" x |
| 357 |
3/4" |
rect. x 5/8" dia.
across corners |
3/4" |
1-3/4" |
15/16" |
*available carded |