HORIZONTAL MAILBOX SPECIFICATIONS

Conform to the strictest architectural specifications and latest U.S. Postal Service Specifications-approved by Postmaster General

 

CONFORMITY TO POSTAL REGULATIONS

Jensen Horizontal Mailboxes conform and are listed in publication 17 August 1978 and approved by the Post Master General, Washington, D.C. and meet all the requirements of the U.S. Postal Service Standard 4A (RE). Postal regulations pertaining to the design and  installation of mail box units in apartment houses are given below for your information. These regulations do change periodically, so for your protection, consult your local Postmaster for information on changing regulations.

INSTALLATION

Font Loading Models:

"In horizontal-type installation, the distance from the finished floor to the tenant locks on the top tier of boxes must be no more than 67 inches; and to the bottom of the lowest tier of boxes, no less than 28 inches."

Rear Loading Models:

"Access to rear loading installation shall be provided by a door fitted with an inside Arrow lock, opening into a room having at least 3 feet of unobstructed work space from the rear of the units to the wall. The room must be adequately ventilated and lighted. The rear of the unit must have a suitable material to prevent the removal of mail from adjacent boxes and to prevent mail from falling out the back. This cover must be securely fastened and easily opened by the carrier."

MASTER DOOR LOCK

Front Loading Models:

Each group of front-loading receptacles must be equipped with a master door which, when open, makes the entire group of boxes accessible for the deposit of mail by the carrier. The master door shall be machined to accommodate an inside Arrow lock furnished by the local Postmaster for use so long as mail is delivered by letter carriers, the key for which shall be in the custody of postal employees. Master doors for horizontal type receptacles shall be hinged on the side only and shall be no wider than 34 inches.

Rear Loading Models:

"Access to rear loading installations shall be provided by a door fitted with an inside Arrow lock opening into a room having at least 3 feet of unobstructed work space from the rear of the units to the wall. The room must be adequately ventilated and lighted. The rear of the unit must have a screen or cover of plywood or other suitable material to prevent the removal of mail from adjacent boxes and to prevent mail from falling out the back. The cover must be securely fastened and easily opened by the carrier." 

NUMBERING OR LETTERING

"Horizontal type receptacles must be numbered or lettered in sequence from top to bottom..."

DIRECTORIES

"In all apartment houses having 15 or more receptacles, a complete directory of all persons receiving mail must be maintained. When an apartment house is divided into units with separate entrances and 15 or more receptacles are installed to the unit, a separate directory must be provided for each unit. In addition, if mail is not generally addressed to specific units, a directory must be kept at the main unit of the building listing all persons receiving mail in the various units. The directory must be of legible type, in a suitable frame for protection purpose, and attached to the wall immediately above or to the side of the mail receptacles where it can be easily read..."

WARRANTY

Please see current Price Sheet for full warranty information.

SERVICE TO BUILDERS

Contact the factory for planning and technical assistance, and for delivery information.

ARCHITECT'S SPECIFICATIONS

FRONT LOADING MODEL 85

Mailboxes shall be manufactured by JENSEN, Los Angeles, CA 90058. They shall be front loading Model Number 85 and conform to the U.S. Postal Regulations. There shall be-individual tenant compartments in-cabinets. (Dimensions are specified.) Installation instructions and diagrams shall be furnished by JENSEN.

REAR LOADING MODEL 90

Mail boxes shall be manufactured by JENSEN, Los Angeles, CA 90058. They shall be rear loading Model Number 90 and conform to the U.S. Postal Regulations. There shall be-individual tenant compartments in-cabinets. (Dimensions are specified.) Installation instructions and diagrams shall be furnished by JENSEN.

INFORMATION REQUIRED TO ORDER:

  1. Mailbox Model No. and Finish.
  2. Numerals to be engraved in compartment doors.
  3. Directory Model No. and Finish.  


1946 East 46th St., Los Angeles, CA 90058-2096

Request for Information / Request a Catalog from Jensen Industries, Inc.
 
 
 
To request more information from Jensen Industries, Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com