Temperature Alarm
Temperature Monitor
For temperature monitoring only. Includes case, AC power supply, temperature probe, audible alarm with reset switch. Can be used with
remote monitor TMSR (below) or with existing monitoring network; maximum distance 1/2 mile. Specify temperature range desired. Available
in 115V 60Hz or 220V 50Hz; specify when ordering.
For Refrigerators, +1°C to +6°C.....Catalog No. TMS-1000
For Freezers, -20°C.....Catalog No. TMS-3000
Remote Monitors
DTPMR. Compatible with DTPM and T1000 series alarm/monitor systems on Jewett blood bank refrigerators and freezers but without digital
display. Signals audible and visual warning in the event of power failure, temperature deviation or door-ajar past time-delay. AC powered with
battery back-up for full-function during power failure. Available in 115V 60Hz or 220V 50Hz; specify when ordering.....Catalog No. DTPMR
TMSR On/Off Monitor. For use with TMS Temperature Monitor only. Operates on AC power, no battery back-up. Available in 115V 60Hz or
220V 50Hz; specify when ordering.....Catalog No. TMSR
Multi-Station Remote Monitor
DTPMR-MS. For use with T100, DTPM, TPM and TMSB series. Signals audible and visual warnings. In the event of power failure or
temperature deviation. AC powered with battery backup for full function during power failure. Can monitor 1 to 12 stations.
115V 60Hz or 220V 50Hz: specify when ordering...Catalog No. DTPMR-MS
For -85°C Red Cell Freezers
Remote Alarm System
Provides an audible/visual signal if temperature increases or power fails. Can be connected to a telephone switchboard. Installs up to 1/3 mile
from freezer. Connects to normally opened or normally closed contacts. Wire not included. Specify freezer voltage when ordering.....Catalog
No. JSC-5612
Electronic Back-Up Systems (CO2 & LN2)
Choose from built-in or free-standing back-up systems. All feature adjustable setpoints, automatic shutoff when opening door, digital
temperature display in 1°C increments, indicator lights for system activation, and self-charging batteries for operation during power-failure
situations.
CO2 Back-Up System. Injects liquid nitrogen into cabinet when cabinet temperature warms to pre-set level. Will maintain -70°C at 10#/hour
flow rate. Adjustable CO2 setpoint to -75°C with digital display and actual cabinet temperature at the push of a button. Includes all hardware
except CO2 cylinder.
CO2 Back-Up, built-in, panel-mounted, factory installed.....Catalog No. JSC-6594
CO2 Back-Up, free-standing, field installed. Specify freezer model number and voltage when ordering.....Catalog No. JSC-6593
LN2 Back-Up System. Injects liquid nitrogen into cabinet when cabinet temperature warms to pre-set level. Will maintain -73°C for 32 hours
from 160 liter cylinder. Adjustable LN2 setpoint to -150°C with digital display and actual cabinet temperature at the push of a button. Includes
all hardware except low pressure liquid nitrogen cylinder.
LN2 Back-Up, built-in, panel-mounted, factory installed.....Catalog No. JSC-6595
LN2 Back-Up, free-standing, field installed. Specify freezer model number and voltage when ordering.....Catalog No. JSC-6214
Inventory Components
Red Cell Press (Canister). Total capacity of LTUR-13 red cell freezer is 200 canisters......Catalog No. JSC-6225
Plasma Rack. Each rack holds 12 400 ml plasma boxes. LTUR-13 freezer holds 20 racks for a total of 240 plasma boxes.....Catalog No.
JSC-6110.
PRODUCT SELECTION
Jewett Blood Bank Refrigerators and Freezers
Model Selection and Configuration
Capacity (Cu.Ft./Units*) |
|
+4°C Refrigerators |
-30°C Plasma Freezers |
-85°C Ultra-Low Red Cell
and Plasma Freezers |
Cylindrical |
BB2 |
15.1/225 |
|
|
Reach-In |
BBR17 |
16.9/240 |
|
|
BBR25 |
24.8/360 |
|
|
BBR37 |
37.4/480 |
|
|
BBR55 |
55/720 |
|
|
BPL13 |
|
13.2/265 |
|
BPL21 |
|
20.7/415 |
|
LTUR13 |
|
|
13.4/2001 |
Undercounter |
CT1 |
5.4/60 |
|
|
CTF1 |
|
5.4/88 |
|
Wall Mounted |
BBWM3 |
3.2/25 |
|
|
BBWM7 |
6.6/66 |
|
|
Walk-In Rooms |
Custom |
available |
available |
|
* Refrigerators rated in 450ml units. Plasma freezers rated in 400ml boxes.
1Standard red cell canisters; red cell freezers may also hold up to 240 plasma units, 400ml.
Shipping Weights and Data
Model |
Standard Ship Weight lbs/kg |
Crated Ship Weight lbs/kg |
Crated Volume ft3/m3 |
BB2 |
455/206 |
440/200 |
62/1.8 |
BBR17 |
525/238 |
515/234 |
62/1.8 |
BBR25 |
670/304 |
635/289 |
69/2.0 |
BBR37 |
840/381 |
880/400 |
119/3.4 |
BBR55 |
1105/507 |
1100/499 |
134/3.8 |
BPL13 |
630/286 |
630/286 |
62/1.8 |
BPL21 |
820/372 |
850/386 |
81/2.3 |
LTUR13 |
600/272 |
765/347 |
78/2.2 |
CT1 |
190/86 |
210/96 |
19/.6 |
CTF1 |
240/109 |
240/109 |
19/.6 |
BBWM3 |
184/84 |
185/84 |
19/.6 |
BBWM7 |
310/141 |
325/148 |
24/.7 |