architecture - engineering - construction
Johns Manville
Commerical Industrial Roofing Systems\Guarantee
Guarantees - Page 6
Commerical Industrial Roofing Systems\Guarantee
![]() |
Guarantees |
| System | Term | Membrane Materials | Dollar Limit | Insulation Substrate | Membrance Spec. | Notes |
| 20 Years | Tricor M FR over Bicor over JM APP Base, APPeX 4.5 M or M FR over APPeX 4S over JM APP Base, APPeX 4.5M or M FR over 2 layers of APPeX 4S, or 2 plies of GPP in Asphalt |
NDL | ![]() |
4GIG, 4GIS, 5GIC (Regions 2 & 3 only), 4GIC (Region 3 only) |
1. GlasPly Premier is the only acceptable ply
felt. 2. New construction or complete tear off only. 3. Insulation must be installed as shown. 4. Tricor M FR over JM APP Base Sheet is the required flashing. 1. Top layer Fesco. 2. 2 plies GlasPly Premier in asphalt. |
|
| 15 Years | Tricor M FR
over JM APP Base, APPeX 4.5M or M FR over APPeX 4S |
NDL | ![]() |
2CIN-W, 2PIN-W |
1. Contact Technical Service
Specialist for recover approval and for approved substrate. 2. Insulation must be installed as shown. 3. 15 year guarantees require Tricor M FR over JM APP Base Sheet as flashing. APPeX 4.5M, Bicor, or APPeX 4S are acceptable flashing for 10 and 12 year guarantees. |
|
| 12 Years | Any guaranteeable JM APP products over JM APP Base Sheet | NDL | ![]() |
2PIN-W 3PIN-W |
||
| 12 Years or 10 Years |
Any
guarantee-able JM APP products over GlasBase fastened with insulation |
Full Value or NDL | None: (approved substrates only) | 2PIN-W 2PBS-W 2PIS-W 2PBS-W |
||
| 10 Years | Any guaranteeable JM APP products over PP28 fastened with insulation, 1 layer of any guaranteeable JM APP products | Full Value | ![]() |
All 3, 4, 5 ply BUR specs (3 ply nailed specs, 5 year only) |
1. GlasTite Flexible must be coated
with an approved coating. 2. Contact Technical Service Specialist for recover approval and for approved substrates. |
|
![]() |
||||||
| None: (approved substrates only) |
- NDL Guarantees are available only to NDL approved contractors.
- Full Value equals the original installed cost of the JM materials and the labor to install them.
- Full Value does not include the costs for tear-off, non-JM material or labor to install non-JM material mat. UltraFast insulation fasteners must be used.
- UltraFast and/or GlasFast must be used.
- Nord Board must be used when heat welding directly to insulation.
- APPeX 180 and APPeX Black Bear are available for Material Warranties only.
- Smooth surface membranes and flashing must be coated with an approved JM coating.
- Flashing must be installed over FesCant Plus cant strips.
- Re-Cover specs require the use of 1/2" Nord Board or mechanically fastened GlasBase Sheet.
![]()