
|
BITUMINOUS FLASHINGS |
|
|
Index of Flashing Specifications
Built-Up Flashing Specifications
FE-1 (LB)
Base Flashing for Load-Bearing Masonry
Parapet Construction with Nailing Facilities
FE-1 (NLB)
Base Flashing for Non Load-Bearing Construction,
Using Roof-to-Wall Expansion Joint Cover
FE-2
Base Flashing for Load-Bearing Masonry Parapet
Construction with No Nailing Facilities
FE-3
Base Flashing for Load-Bearing Wood Parapet
Construction Less Than 24" (610 mm) Above the
Roof Membrane
FE-4, FE-4
Roof Edges and Gravel Stops
FE-5
Base Flashing for Non Load-Bearing Construction
(Alternate)
FE-7
Curb Mounted Roof-to-Roof Expansion Joint Cover
FE-8
Flashing to Prefabricated Curb
FE-9
Plumbing Vent Flashing
FE-10
FP-10 One-Way Roof Vent
FE-11
Flashing to Metal Drain
FE-12
Flashing to JM Flex-I-Drain
FE-15
High Wall Flashing for Load-Bearing Masonry
Wall Construction
FE-15(N)
High Wall Flashing for Load-Bearing Wood Wall
Construction
FE-16
Flashing of Roof Penetration Pan
FE-17
Lightning Rod on Roof Surface
IMPORTANT:
JM requires the use of DynaFlex or DynaClad as the base flashing material for all No Dollar Limit (NDL) Guaranteed BUR and SBS systems.
Penal sum BUR specifications over 10 years may use GlasTite Flexible with a backer felt and coating or DynaFlex. Penal sum BUR
specifications up to and including 10 years may use GlasTite Flexible with a coating (no backer felt required). For DynaFlex details, refer to
the "DFE-" details.
SBS Modified Bitumen Flashing Specifications
DFE-1 (LB)
Base Flashing for Load-Bearing Masonry Parapet
Construction with Nailing Facilities
DFE-1 (NLB)
Base Flashing for Non Load-Bearing Construction,
Using Roof-to-Wall Expansion Joint Cover
DFE-2
Base Flashing for Load-Bearing Masonry Parapet
Construction with No Nailing Facilities
DFE-3 (WL)
Base Flashing for Load-Bearing Wood Parapet
Construction Less Than 24" (610 mm) Above the
Roof Membrane
DFE-3 (WH), DFE-3 (WH)
Base Flashing and Wall Covering for Load-
Bearing Wood Parapet Construction More Than
24" (610 mm) Above the Roof Membrane
DFE-4, DFE-4
Roof Edges and Gravel Stops
DFE-5
Base Flashing for Non Load-Bearing Construction (Alternate)
DFE-6 (TL)
Base Flashing for Tilt-Up Construction Walls Less
Than 24" (610 mm) Above the Roof Membrane
DFE-6 (TH), DFE-6 (TH)
Base Flashing and Wall Covering for Tilt-Up
Construction Walls More Than 24" (610 mm)
Above the Roof Membrane
DFE-7
Curb Mounted Roof-to-Roof Expansion Joint Cover
DFE-8
Flashing to Prefabricated Curb
DFE-9
Plumbing Vent Flashing
DFE-10
FP-10 One-Way Roof Vent
DFE-11
Flashing to Metal Drain
DFE-12
Flashing to JM Flex-I-Drain
DFE-15
High Wall Flashing for Load-Bearing Masonry
Wall Construction
DFE-15(N)
High Wall Flashing for Load-Bearing Wood Wall
Construction
DFE-16
Flashing of Roof Penetration Pan
DFE-17
Lightning Rod on Roof Surface
DFE-18 (LB)
DynaClad Base Flashing for Load-Bearing
Masonry Construction
APP/PAO Modified Bitumen Flashing Specifications
WFE-1 (LB)
Base Flashing for Load-Bearing Masonry Construction
WFE-1 (NLB)
Base Flashing for Non Load-Bearing Masonry
Construction
WFE-2
Base Flashing for Masonry Constructions
WFE-4
Gravel Stops and Roof Edges
WFE-5
Base Flashing for Decks with Non Load-Bearing Walls
WFE-7
Base Flashing for Roof-to-Roof Expansion Joint Cover
WFE-9
Vent Pipe Flashing
WFE-10
FP-10 One Way Roof Vent
WFE-11
Drains over Smooth Surfaced and Mineral Surfaced
Systems
WFE-13
Flashing for Through-Wall Scuppers
WFE-19
Corner Flashing Sequence
WFE-20
Transition to Shingled Roof Flashing