Description
½" Retro-Fit Board is a high density board made of expanded perlite and cellulosic fibers. It serves as an upgrade for wood fiber utility roofing products. The top surface is sealed with TopLoc coating to ensure optimum attachment in asphaltic applications. The TopLoc coating gives Retro-Fit Board a smoother surface for easier application of hot asphalt or cold adhesives.
Application
½" Retro-Fit Board is a perlite-based utility board for use as a divorcing layer in reroofing and in new construction as a top layer in a multi-layer insulation system. It may be applied with hot asphalt, cold adhesive or mechanical fasteners. It is not recommended for use directly over steel decks.
Sizes
2' x 4' (0.61 m x 1.22 m), 4' x 4' (1.22 m x 1.22 m) and 4' x 8' (1.22 m x 2.44 m), with a nominal thickness of ½" (13 mm).
Advantages
Environmentally Friendly. The minimum recycled
content is 35% by weight.
½ " Retro-Fit Board complies with Environmental
Protection Agency Regulation 40 CFR Part 248,
Guideline for Federal Procurement of Building
Insulation Products Containing Recovered
Materials, as a recycled product approved for
use on any project using federal funds.
Strength and Durability. When applied over rigid decks, ½ " Retro-Fit Board’s high laminar tensile strength resists damage from on-the-job and maintenance traffic, offers an excellent substrate for all roofing membranes.
Dimensional Stability. Because of its perlite composition and low water absorption rates, ½" Retro-Fit Board is dimensionally stable over a wide range of weather conditions.
Fire Resistance. ½" Retro-Fit Board has excellent fire resistance and is approved for use in FM and UL approved constructions. Because of its perlite content, ½ " Retro-Fit Board offers far greater fire resistance than conventional wood fiber materials.
Mopping Surface. ½" Retro-Fit Board provides an excellent base to receive a built-up or modified bitumen membrane. It has excellent compatibility with hot asphalt.
Good Adhesion. The top surface of ½ " Retro-Fit Board is sealed with TopLoc coating to control the penetration of mopping asphalt, helping to ensure proper adhesion of the roofing membrane.
Stable R-Value. ½ " Retro-Fit Board has a stable R-value because it is composed of inorganic and fibrous materials.

Applicable Standards
½ " Retro-Fit Board complies with the material requirements of ASTM C 728.

Factory Mutual
½" Retro-Fit Board has been rated in Factory Mutual fire and wind-resistant systems for BUR, single ply and modified bitumen constructions. This testing is specific to the roof deck, insulation, fastener, fastener pattern and the membrane. For current information on JM FM approved systems, contact a JM Technical Service Specialist, JM Sales Representative or consult the current FM Approval Guide.
Underwriters Laboratories
½" Retro-Fit Board is also classified by Underwriters Laboratories, Inc. and is an approved insulation for numerous Class A roof constructions. Contact a JM Technical Service Specialist for details regarding specific approvals.
Other Approvals
½ " Retro-Fit Board has been approved by numerous municipalities including Dade County, FL. ½" Retro-Fit Board also meets the requirements of BOCA, ICBO, SBBCI and others. Please contact a JM Technical Service Specialist for details.