architecture - engineering - construction
Justice Design Group
Lexington
Lexington - Page 13
Lexington
| 8' to 18' Round Tapered 4-Bolt Anchor
Base Standards Detail 
ANCHOR
BASE AND BOLT DETAIL |
A
Pole Diameter |
B
Bolt Circle |
C
Bolt Projection |
D
Bolt Size |
E
Conduit Opening |
F
Base Size |
| 4" |
6-1/2" - 8-1/4" |
3-1/4" |
3/4" x 15" |
3-3/4" |
8-3/4" |
| 5" |
7-1/2" - 9-1/2" |
3-1/4" |
3/4" x 15" |
4-1/2" |
9-1/4" |
| 6" |
8-3/4" - 10-1/4" |
3-1/2" |
3/4" x 25" |
5-1/2" |
10-1/4" |
| 7" |
9-7/8" - 11-1/4" |
4-1/8" |
1" x 36" |
6-1/2" |
10-5/8" |
TYPICAL
WEIGHT AND ALLOWABLE SIZE OF LUMINAIRES* |
DIMENSIONS
OF STANDARDS |
| Nominal
Mounting Height |
Typical
Luminaire Weight (lbs.) |
Effective
Projected Area in Square Feet at: |
|
| 70 |
80 |
90 |
100 |
110 |
Standard |
|
Lexington |
| MPH |
MPH |
MPH |
MPH |
MPH |
Height |
Top |
Butt |
Wall |
Model Number |
| 8' |
75 |
16.1 |
12.1 |
9.3 |
7.3 |
5.9 |
7' 8" |
3" |
4" |
.125" |
0708-30404T4 |
| 10' |
75 |
11.9 |
8.8 |
6.7 |
5.2 |
4.1 |
9' 8" |
3" |
4" |
.125" |
0908-30404T4 |
| 10' |
75 |
19.7 |
14.7 |
11.4 |
9.0 |
7.3 |
9' 8" |
3" |
5" |
.125" |
0908-30504T4 |
| 12' |
75 |
9.1 |
6.6 |
4.8 |
3.6 |
2.8 |
11' 8" |
3" |
4" |
.125" |
1108-30404T4 |
| 12' |
75 |
15.4 |
11.4 |
8.7 |
6.8 |
5.4 |
11' 8" |
3" |
5" |
.125" |
1108-30504T4 |
| 12' |
75 |
19.4 |
14.4 |
11.1 |
8.7 |
7.0 |
11' 8" |
3" |
5" |
.156" |
1108-30505T4 |
| 12' |
150 |
23.0 |
17.2 |
13.3 |
10.5 |
8.5 |
11' 8" |
3" |
5" |
.188" |
1108-30506T4 |
| 14' |
75 |
6.9 |
4.9 |
3.4 |
2.4 |
1.8 |
13' 8" |
3" |
4" |
.125" |
1308-30404T4 |
| 14' |
75 |
12.3 |
8.9 |
6.6 |
5.1 |
4.0 |
13' 8" |
3" |
5" |
.125" |
1308-30504T4 |
| 14' |
75 |
15.6 |
11.4 |
8.6 |
6.7 |
5.3 |
13' 8" |
3" |
5" |
.156" |
1308-30505T4 |
| 14' |
150 |
18.6 |
13.7 |
10.5 |
8.2 |
6.6 |
13' 8" |
3" |
5" |
.188" |
1308-30506T4 |
| 16' |
75 |
5.3 |
3.5 |
2.3 |
1.5 |
0.9 |
15' 8" |
3" |
4" |
.125" |
1508-30404T4 |
| 16' |
75 |
9.8 |
6.9 |
5.0 |
3.8 |
2.9 |
15' 8" |
3" |
5" |
.125" |
1508-30504T4 |
| 16' |
75 |
12.6 |
9.1 |
6.8 |
5.2 |
4.0 |
15' 8" |
3" |
5" |
.156" |
1508-30505T4 |
| 16' |
150 |
15.1 |
11.0 |
8.3 |
6.4 |
5.1 |
15' 8" |
3" |
5" |
.188" |
1508-30506T4 |
| 16' |
150 |
19.0 |
14.1 |
10.8 |
8.6 |
7.0 |
15' 8" |
4" |
6" |
.156" |
1508-40605T4 |
| 16' |
150 |
23.2 |
17.3 |
13.4 |
10.7 |
8.7 |
15' 8" |
4" |
6" |
.188" |
1508-40606T4 |
| 18' |
150 |
7.4 |
5.5 |
3.5 |
2.5 |
1.8 |
17' 8" |
3" |
5" |
.125" |
1708-30504T4 |
| 18' |
150 |
9.9 |
7.0 |
5.0 |
3.7 |
2.8 |
17' 8" |
3" |
5" |
.156" |
1708-30505T4 |
| 18' |
150 |
12.4 |
8.8 |
6.5 |
4.9 |
3.8 |
17' 8" |
3" |
5" |
.188" |
1708-30506T4 |
| 18' |
150 |
15.7 |
11.5 |
8.7 |
6.9 |
5.5 |
17' 8" |
4" |
6" |
.156" |
1708-40605T4 |
| 18' |
150 |
19.4 |
14.3 |
11.0 |
8.7 |
7.0 |
17' 8" |
4" |
6" |
.188" |
1708-40606T4 |
| 18' |
150 |
23.2 |
17.2 |
13.3 |
10.6 |
8.6 |
17' 8" |
4" |
7" |
.156" |
1708-40705T4 |
* E.P.A. calculations allow for 1.3 gust factor.
Variations from sizes listed above are available upon
inquiry at the factory.
Satisfactory performance of lighting standards are
dependent upon the standard being properly attached to a supporting foundation of adequate
design. Lexington does not design or offer recommendations for foundations. |