architecture - engineering - construction
Justice Design Group
Lexington
Lexington - Page 18
Lexington
8' to 20' Round Tapered 3-Bolt
Triangular Anchor Base Standards Detail
ANCHOR
BASE AND BOLT DETAIL |
DIMENSIONS OF SPUN COLLAR |
| A Pole
Diameter |
B Bolt Circle |
C Bolt
Projection |
D Minimum Bolt
Size |
E Conduit
Opening |
Outside Diameter |
Height |
| 4" |
6-5/16" - 7-3/8" |
3-1/4" |
3/4" x 15" |
3-3/4" |
9-1/4" |
5-1/2" |
| 5" |
7-3/8" - 8-1/2" |
3-1/4" |
3/4" x 15" |
4-1/2" |
10-1/2" |
5-1/2" |
TYPICAL
WEIGHT AND ALLOWABLE SIZE OF LUMINAIRES* |
DIMENSIONS
OF STANDARDS |
| Nominal
Mounting Height |
Typical
Luminaire Weight (lbs.) |
Effective
Projected Area in Square Feet at: |
|
| 70 |
80 |
90 |
100 |
110 |
Standard |
|
Lexington |
| MPH |
MPH |
MPH |
MPH |
MPH |
Height |
Top |
Butt |
Wall |
Model Number |
| 8' |
75 |
16.1 |
12.1 |
9.3 |
7.3 |
5.9 |
7' 8" |
3" |
4" |
.125" |
0708-30404T3 |
| 10' |
75 |
11.9 |
8.8 |
6.7 |
5.2 |
4.1 |
9' 8" |
3" |
4" |
.125" |
0908-30404T3 |
| 10' |
75 |
19.7 |
14.7 |
11.4 |
9.0 |
7.3 |
9' 8" |
3" |
5" |
.125" |
0908-30504T3 |
| 12' |
75 |
9.1 |
6.6 |
4.8 |
3.6 |
2.8 |
11' 8" |
3" |
4" |
.125" |
1108-30404T3 |
| 12' |
75 |
15.5 |
11.4 |
8.7 |
6.8 |
5.4 |
11' 8" |
3" |
5" |
.125" |
1108-30504T3 |
| 12' |
75 |
19.4 |
14.4 |
11.1 |
8.7 |
7.0 |
11' 8" |
3" |
5" |
.156" |
1108-30505T3 |
| 12' |
150 |
23.0 |
17.2 |
13.3 |
10.5 |
8.5 |
11' 8" |
3" |
5" |
.188" |
1108-30506T3 |
| 14' |
75 |
7.0 |
4.9 |
3.4 |
2.4 |
1.8 |
13' 8" |
3" |
4" |
.125" |
1308-30404T3 |
| 14' |
75 |
12.3 |
8.9 |
6.6 |
5.1 |
4.0 |
13' 8" |
3" |
5" |
.125" |
1308-30504T3 |
| 14' |
75 |
15.6 |
11.4 |
8.6 |
6.7 |
5.3 |
13' 8" |
3" |
5" |
.156" |
1308-30505T3 |
| 14' |
150 |
19.2 |
14.2 |
10.8 |
8.5 |
6.8 |
13' 8" |
3" |
5" |
.188" |
1308-30506T3 |
| 16' |
75 |
5.3 |
3.5 |
2.3 |
1.5 |
0.9 |
15' 8" |
3" |
4" |
.125" |
1508-30404T3 |
| 16' |
75 |
9.8 |
6.9 |
5.0 |
3.8 |
2.9 |
15' 8" |
3" |
5" |
.125" |
1508-30504T3 |
| 16' |
75 |
12.6 |
9.1 |
6.8 |
5.2 |
4.0 |
15' 8" |
3" |
5" |
.156" |
1508-30505T3 |
| 16' |
150 |
15.1 |
11.0 |
8.3 |
6.4 |
5.1 |
15' 8" |
3" |
5" |
.188" |
1508-30506T3 |
| 18' |
150 |
7.4 |
5.0 |
3.5 |
2.5 |
1.8 |
17' 8" |
3" |
5" |
.125" |
1708-30504T3 |
| 18' |
150 |
9.9 |
7.0 |
5.0 |
3.7 |
2.8 |
17' 8" |
3" |
5" |
.156" |
1708-30505T3 |
| 18' |
150 |
12.4 |
8.8 |
6.5 |
4.9 |
3.8 |
17' 8" |
3" |
5" |
.188" |
1708-30506T3 |
| 20' |
150 |
5.9 |
3.8 |
2.5 |
1.6 |
1.0 |
19' 8" |
3" |
5" |
.125" |
1908-30504T3 |
| 20' |
150 |
8.1 |
5.5 |
3.8 |
2.6 |
1.9 |
19' 8" |
3" |
5" |
.156" |
1908-30505T3 |
| 20' |
150 |
10.3 |
7.2 |
5.1 |
3.7 |
2.8 |
19' 8" |
3" |
5" |
.188" |
1908-30506T3 |
* E.P.A. calculations allow for 1.3 Gust Factor.
Variations from sizes listed above are available upon
inquiry at the factory.
Satisfactory performance of lighting standards are
dependent upon the standard being properly attached to a supporting foundation of adequate
design. Lexington does not design or offer recommendations for foundations. |