architecture - engineering - construction
Justice Design Group
Lexington
Lexington - Page 22
Lexington
| 8' to 30' Round Tapered Embedded
(Direct Burial) Standards Detail 
| A BOTTOM DIAMETER |
B EMBEDDED LENGTH |
| 4" |
3' |
| 5" |
4' |
| 6" |
4' |
| 7" |
5' |
| 8" |
5' |
TYPICAL
WEIGHT AND ALLOWABLE SIZE OF LUMINAIRES* |
DIMENSIONS
OF STANDARDS |
| Nominal
Mounting Height* |
Typical
Luminaire Weight (lbs.) |
Effective
Projected Area in Square Feet at: |
|
Overall |
|
|
| 70 |
80 |
90 |
100 |
110 |
Exposed |
Shaft |
Lexington |
| MPH |
MPH |
MPH |
MPH |
MPH |
Height |
Length |
Top |
Butt |
Wall |
Model Number |
| 8' |
75 |
19.1 |
14.4 |
11.1 |
8.8 |
7.1 |
7' 8" |
10' 8" |
3" |
4" |
.125" |
0708-30404TE |
| 10' |
75 |
14.3 |
10.6 |
8.1 |
6.3 |
5.0 |
9' 8" |
12' 8" |
3" |
4" |
.125" |
0908-30404TE |
| 12' |
75 |
11.0 |
8.0 |
6.0 |
4.5 |
3.5 |
11' 8" |
14' 8" |
3" |
4" |
.125" |
1108-30404TE |
| 12' |
75 |
18.5 |
13.8 |
10.5 |
8.3 |
6.6 |
11' 8" |
15' 8" |
3" |
5" |
.125" |
1108-30504TE |
| 14' |
75 |
8.5 |
6.0 |
4.4 |
3.2 |
2.4 |
13' 8" |
16' 8" |
3" |
4" |
.125" |
1308-30404TE |
| 14' |
75 |
14.8 |
10.8 |
8.2 |
6.3 |
5.0 |
13' 8" |
17' 8" |
3" |
5" |
.125" |
1308-30504TE |
| 16' |
75 |
7.1 |
5.0 |
3.5 |
2.4 |
1.7 |
15' 8" |
18' 8" |
3" |
4" |
.125" |
1508-30404TE |
| 16' |
75 |
12.0 |
8.6 |
6.4 |
4.8 |
3.8 |
15' 8" |
19' 8" |
3" |
5" |
.125" |
1508-30504TE |
| 16' |
75 |
15.3 |
11.1 |
8.4 |
6.5 |
5.1 |
15' 8" |
19' 8" |
3" |
5" |
.156" |
1508-30505TE |
| 18' |
75 |
9.7 |
6.7 |
4.9 |
3.6 |
2.7 |
17' 8" |
21' 8" |
3" |
5" |
.125" |
1708-30504TE |
| 18' |
150 |
12.2 |
8.7 |
6.4 |
4.9 |
3.8 |
17' 8" |
21' 8" |
3" |
5" |
.156" |
1708-30505TE |
| 18' |
150 |
19.1 |
14.1 |
10.8 |
8.5 |
6.9 |
17' 8" |
21' 8" |
4" |
6" |
.156" |
1708-40605TE |
| 20' |
75 |
8.2 |
5.5 |
3.8 |
2.6 |
1.9 |
19' 8" |
23' 8" |
3" |
5" |
.125" |
1908-30504TE |
| 20' |
75 |
10.4 |
7.2 |
5.1 |
3.7 |
2.8 |
19' 8" |
23' 8" |
3" |
5" |
.156" |
1908-30505TE |
| 25' |
150 |
10.5 |
7.1 |
5.1 |
3.8 |
2.9 |
24' 8" |
28' 8" |
4" |
6" |
.156" |
2408-40605TE |
| 25' |
150 |
13.5 |
9.4 |
6.9 |
5.3 |
4.2 |
24' 8" |
28' 8" |
4" |
6" |
.188" |
2408-40606TE |
| 30' |
150 |
11.1 |
7.5 |
5.3 |
4.0 |
3.0 |
29' 8" |
34' 8" |
4" |
7" |
.156" |
2908-40705TE |
| 30' |
150 |
16.7 |
12.0 |
9.1 |
7.0 |
5.5 |
29' 8" |
34' 8" |
4-1/2" |
8" |
.156" |
2908-45805TE |
* E.P.A. calculations allow for 1.3 Gust Factor. If mast or
truss arms are to be installed, contact Lexington Standard Corporation for E.P.A.
information and recommended shaft length.
Variations from standard sizes listed above, available upon
inquiry at the factory.
Satisfactory performance of lighting standards is dependent
upon the standard being properly attached to a supporting foundation of adequate design.
Lexington does not design or offer recommendations for foundations. |