architecture - engineering - construction
Justice Design Group
Lexington
Lexington - Page 32
Lexington
| 8' to 20' Round Straight Hinged Base
Standards Detail 
ANCHOR
BASE AND BOLT DETAIL |
BASE
DIMENSIONS |
| A Pole
Diameter |
B Bolt Circle |
C Bolt
Projection |
D Bolt Size |
E Conduit
Opening |
Conduit Projection |
F Diameter |
G Height |
| 4" |
8-1/2" - 10" |
3-1/2" |
3/4" x 15" |
3-1/2" |
1-1/2" |
12-5/8" |
3-1/16" |
| 5" |
8-1/2" - 10" |
3-1/2" |
3/4" x 15" |
4-1/2" |
1-1/2" |
12-5/8" |
3-1/16" |
| 6" |
8-1/2" - 10" |
3-1/2" |
3/4" X 25" |
5-1/2" |
1-1/2" |
12-5/8" |
3-1/16" |
TYPICAL
WEIGHT AND ALLOWABLE SIZE OF LUMINAIRES* |
DIMENSIONS
OF STANDARDS |
| Nominal
Mounting Height |
Luminaires
Typical Weight (lbs.) |
Effective
Projected Area in Square Feet at: |
|
| 70 |
80 |
90 |
100 |
110 |
Pole |
Outside |
|
Lexington |
| MPH |
MPH |
MPH |
MPH |
MPH |
Height |
Diameter |
Wall |
Model Number |
| 8' |
50 |
15.1 |
11.3 |
8.6 |
6.8 |
5.6 |
8' |
4" |
.125" |
0800-40404SH |
| 10' |
50 |
11.2 |
8.2 |
6.1 |
4.7 |
3.8 |
10' |
4" |
.125" |
1000-40404SH |
| 10' |
50 |
18.5 |
13.8 |
10.8 |
8.6 |
7.0 |
10' |
5" |
.125" |
1000-50504SH |
| 12' |
50 |
8.5 |
6.1 |
4.4 |
3.3 |
2.6 |
12' |
4" |
.125" |
1200-40404SH |
| 12' |
50 |
14.4 |
10.5 |
8.2 |
6.5 |
5.3 |
12' |
5" |
.125" |
1200-50504SH |
| 12' |
50 |
18.2 |
13.5 |
10.5 |
8.4 |
6.8 |
12' |
5" |
.156" |
1200-50505SH |
| 12' |
50 |
22.0 |
16.4 |
12.8 |
10.2 |
8.3 |
12' |
5" |
.188" |
1200-50506SH |
| 14' |
50 |
6.5 |
4.4 |
3.0 |
2.1 |
1.6 |
14' |
4" |
.125 |
1400-40404SH |
| 14' |
50 |
11.3 |
8.1 |
6.2 |
4.9 |
3.9 |
14' |
5" |
.125" |
1400-50504SH |
| 14' |
50 |
14.5 |
10.6 |
8.2 |
6.5 |
5.2 |
14' |
5" |
.156" |
1400-50505SH |
| 14' |
50 |
17.7 |
13.0 |
10.1 |
8.0 |
6.5 |
14' |
5" |
.188" |
1400-50506SH |
| 16' |
50 |
4.9 |
3.1 |
1.9 |
1.2 |
0.8 |
16' |
4" |
.125" |
1600-40404SH |
| 16' |
50 |
8.9 |
6.2 |
4.7 |
3.6 |
2.8 |
16' |
5" |
.125" |
1600-50504SH |
| 16' |
50 |
11.6 |
8.3 |
6.3 |
5.0 |
4.0 |
16' |
5" |
.156" |
1600-50505SH |
| 16' |
50 |
14.4 |
10.4 |
8.0 |
6.3 |
5.1 |
16' |
5" |
.188" |
1600-50506SH |
| 16' |
50 |
18.4 |
13.8 |
10.7 |
8.5 |
6.9 |
16' |
6" |
.156" |
1600-60605SH |
| 16' |
50 |
22.5 |
17.0 |
13.2 |
10.6 |
8.6 |
16' |
6" |
.188" |
1600-60606SH |
| 18' |
75 |
6.8 |
4.5 |
3.3 |
2.5 |
1.9 |
18' |
5" |
.125" |
1800-50504SH |
| 18' |
75 |
9.2 |
6.4 |
4.8 |
3.7 |
2.9 |
18' |
5" |
.156" |
1800-50505SH |
| 18' |
75 |
11.6 |
8.2 |
6.2 |
4.9 |
3.9 |
18' |
5" |
.188" |
1800-50506SH |
| 18' |
75 |
18.8 |
14.1 |
10.9 |
8.6 |
7.0 |
18' |
6" |
.188" |
1800-60606SH |
| 20' |
75 |
5.1 |
3.2 |
2.2 |
1.6 |
1.1 |
20' |
5" |
.125" |
2000-50504SH |
| 20' |
75 |
7.3 |
4.8 |
3.5 |
2.6 |
2.0 |
20' |
5" |
.156" |
2000-50505SH |
| 20' |
75 |
9.4 |
6.4 |
4.8 |
3.7 |
2.9 |
20' |
5" |
.188" |
2000-50506SH |
| 20' |
75 |
12.5 |
9.2 |
7.0 |
5.5 |
4.4 |
20' |
6" |
.156" |
2000-60605SH |
| 20' |
75 |
15.7 |
11.7 |
9.0 |
7.1 |
5.7 |
20' |
6" |
.188" |
2000-60606SH |
CAUTION: Raising or lowering of the pole requires adequate
preparation. Do not underestimate the force required to raise or lower poles with heavy
luminaires at the top.
HANDHOLES: Peripherally reinforced handholes are available
as an accessory.
Variations from standard sizes listed above, available upon
inquiry at factory. *EPA calculations allow for 1.3 Gust Factor.
Satisfactory performance of lighting standards is dependent
upon the standard being properly attached to a supporting foundation of adequate design.
Lexington does not design or offer recommendations for foundations. |