| 8' to 20' Round Tapered Hinged Base
Standards Detail 
ANCHOR
BASE AND BOLT DETAIL |
BASE
DIMENSIONS |
| A Pole
Diameter |
B Bolt Circle |
C Bolt
Projection |
D Bolt Size |
E Conduit
Opening |
Conduit Projection |
F Diameter |
G Height |
| 4" |
8-1/2" - 10" |
3-1/2" |
3/4" x 15" |
3-1/2" |
1-1/2" |
12-5/8" |
3-1/16" |
| 5" |
8-1/2" - 10" |
3-1/2" |
3/4" x 15" |
4-1/2" |
1-1/2" |
12-5/8" |
3-1/16" |
| 6" |
8-1/2" - 10" |
3-1/2" |
3/4" X 25" |
5-1/2" |
1-1/2" |
12-5/8" |
3-1/16" |
TYPICAL
WEIGHT AND ALLOWABLE SIZE OF LUMINAIRES* |
DIMENSIONS
OF STANDARDS |
| Nominal
Mounting Height |
Luminaires
Typical Weight (lbs.) |
Effective
Projected Area in Square Feet at: |
|
| 70 |
80 |
90 |
100 |
110 |
Pole |
|
|
|
Lexington |
| MPH |
MPH |
MPH |
MPH |
MPH |
Height |
Top |
Butt |
Wall |
Model Number |
| 8' |
50 |
16.1 |
12.1 |
9.3 |
7.3 |
5.9 |
7' 8" |
3" |
4" |
.125" |
0708-30404TH |
| 10' |
50 |
12.0 |
8.9 |
6.7 |
5.2 |
4.1 |
9' 8" |
3" |
4" |
.125" |
0908-30404TH |
| 10' |
50 |
19.7 |
14.7 |
11.4 |
9.0 |
7.3 |
9' 8" |
3" |
5" |
.125" |
0908-30504TH |
| 12' |
50 |
9.1 |
6.6 |
4.9 |
3.6 |
2.8 |
11' 8" |
3" |
4" |
.125" |
1108-30404TH |
| 12' |
50 |
15.5 |
11.5 |
8.7 |
6.8 |
5.4 |
11' 8" |
3" |
5" |
.125" |
1108-30504TH |
| 12' |
50 |
19.4 |
14.5 |
11.1 |
8.7 |
7.0 |
11' 8" |
3" |
5" |
.156" |
1108-30505TH |
| 12' |
50 |
23.4 |
17.5 |
13.5 |
10.6 |
8.6 |
11' 8" |
3" |
5" |
.188" |
1108-30506TH |
| 14' |
50 |
7.0 |
4.9 |
3.5 |
2.5 |
1.8 |
13' 8" |
3" |
4" |
.125 |
1308-30404TH |
| 14' |
50 |
12.3 |
9.0 |
6.7 |
5.1 |
4.0 |
13' 8" |
3" |
5" |
.125" |
1308-30504TH |
| 14' |
50 |
15.6 |
11.5 |
8.7 |
6.7 |
5.3 |
13' 8" |
3" |
5" |
.156" |
1308-30505TH |
| 14' |
50 |
18.9 |
14.0 |
10.7 |
8.4 |
6.7 |
13' 8" |
3" |
5" |
.188" |
1308-30506TH |
| 16' |
50 |
5.4 |
3.6 |
2.4 |
1.5 |
1.0 |
15' 8" |
3" |
4" |
.125" |
1508-30404TH |
| 16' |
50 |
9.9 |
7.0 |
5.1 |
3.8 |
2.9 |
15' 8" |
3" |
5" |
.125" |
1508-30504TH |
| 16' |
50 |
12.6 |
9.1 |
6.8 |
5.2 |
4.0 |
15' 8" |
3" |
5" |
.156" |
1508-30505TH |
| 16' |
75 |
15.4 |
11.2 |
8.5 |
6.5 |
5.2 |
15' 8" |
3" |
5" |
.188" |
1508-30506TH |
| 16' |
75 |
19.2 |
14.2 |
11.0 |
8.7 |
7.0 |
15' 8" |
4" |
6" |
.156" |
1508-40605TH |
| 16' |
75 |
23.4 |
17.5 |
13.5 |
10.8 |
8.8 |
15' 8" |
4" |
6" |
.188" |
1508-40606TH |
| 18' |
50 |
7.9 |
5.4 |
3.8 |
2.7 |
2.0 |
17' 8" |
3" |
5" |
.125" |
1708-30504TH |
| 18' |
75 |
10.2 |
7.2 |
5.2 |
3.9 |
3.0 |
17' 8" |
3" |
5" |
.156" |
1708-30505TH |
| 18' |
75 |
12.7 |
9.1 |
6.7 |
5.1 |
4.0 |
17' 8" |
3" |
5" |
.188" |
1708-30506TH |
| 18' |
75 |
15.9 |
11.7 |
8.9 |
7.0 |
5.6 |
17' 8" |
4" |
6" |
.156" |
1708-40605TH |
| 18' |
75 |
19.6 |
14.5 |
11.1 |
8.8 |
7.1 |
17' 8" |
4" |
6" |
.188" |
1708-40606TH |
| 20' |
75 |
6.3 |
4.1 |
2.7 |
1.7 |
1.1 |
19' 8" |
3" |
5" |
.125" |
1908-30504TH |
| 20' |
75 |
8.5 |
5.8 |
4.0 |
2.8 |
2.0 |
19' 8" |
3" |
5" |
.156" |
1908-30505TH |
| 20' |
75 |
10.7 |
7.5 |
5.3 |
3.9 |
2.9 |
19' 8" |
3" |
5" |
.188" |
1908-30506TH |
| 20' |
75 |
13.3 |
9.5 |
7.1 |
5.5 |
4.4 |
19' 8" |
4" |
6" |
.156" |
1908-40605TH |
| 20' |
75 |
16.6 |
12.0 |
9.1 |
7.7 |
5.7 |
19' 8" |
4" |
6" |
.188" |
1908-40606TH |
CAUTION: Raising or lowering of the pole requires adequate
preparation. Do not underestimate the force required to raise or lower poles with heavy
luminaires at the top.
HANDHOLES: Peripherally reinforced handholes are available
as an accessory.
Variations from standard sizes listed above, available upon
inquiry at factory. *EPA calculations allow for 1.3 Gust Factor. Pole height includes
pedestal base. Satisfactory performance of lighting standards is dependent upon the
standard being properly attached to a supporting foundation of adequate design. Lexington
does not design or offer recommendations for foundations. |