 Kemlite Company  Glasbord  

Glasbord - Page 4

 

 

PRODUCT SPECIFICATIONS

Materials

  1. Acceptable panels: See Product Selection Chart
  2. Division Bars, Corner Trim: Kemlite standard length extruded vinyl pieces: longest length possible - to eliminate end joints.
  3. Fasteners: Non-corrosive drive rivets.

Preparation

  1. Examine backup surfaces to determine that corners are plumb and straight, surfaces are smooth, uniform, clean and free from foreign matter, nails countersunk, joints and cracks filled flush and smooth with the adjoining surface.
  2. Do not begin installation until backup surfaces are put into satisfactory condition.

Application

  1. Do all cutting with carbide tipped saw blades or drill bits, or cut with snips.
  2. Install panels with manufacturer's recommended gap at panel joints.
  3. Fastener holes in the panels must be predrilled 1/8" (3.2mm) oversize.
  4. For trowel type and application of adhesive, follow adhesive manufacturer's recommendation.
  5. Using products acceptable to manufacturer, install the frp panel system in accordance with panel manufacturer's printed instructions, Installation Guide #6211.

Cleaning

Remove any adhesive or excessive sealant from panel face using solvent or cleaner recommended by Kemlite.

 

GLASBORD® Panel Property Selection Chart

Property Fire-X Glasbord Glasbord-FSI Glasbord-P Glasbord-PSI Glasbord-CGI
Surface Burning Characteristics (I) Class A (I) Class A (I) Class C (III) Class C (III) Class C (III)
Thickness .09" (2.3mm) .075" (1.9mm) .09" (2.3mm) .075" (1.9mm) .010" (2.5mm)
Finish Embossed Smooth Embossed Smooth Embossed
Wall Panel Yes Yes Yes Yes No
Ceiling Panel Yes No No No Yes
Colors Six Standard White Six Standard White White
Certification UL Classified FMRC Approved ICBO NY MEA USDA/FSIS USDA/FSIS ICBO USDA/FSIS USDA/FSIS USDA/FSIS
Flex Strength

PSI (kg/cm2)

15,000

(1,050)

14,000

(980)

9,000

(635)

13,000

(914)

10,000

(703)

Flex Modulus

PSI (kg/cm2)

850,000

(60,000)

1,000,000

(70,300)

420,000

(29,530)

975,000

(68,543)

975,000

(68,550)

Tensile Strength

PSI (mg/cm2)

6,500

(450)

7,000

(490)

4,300

(300)

6,800

(478)

3,600

(253)

Tensile Modulus

PSI (kg/cm2)

1,300,000

(91,000)

1,300,000

(91,400)

660,000

(46,400)

1,125,000

(79,088)

1,400,000

(98,400)

Barcol Hardness 55 52 42 55 60
Izod Impact Strength

In.-lb/in. (cm-kg/cm)

10.6 (.56) 11.0 (.58) 6.7 (.35) 11.0 (.58) 6.3 (.38)
Gardner Impact Strength

in.-lb/in. (cm-kg/cm)

40 (46.5) 30 (35) 16 (19) 18 (21) n/a
Coefficient of Linear Thermal Expansion

in/in•°F (cm/cm•°C)

1.7 x 10-5

(30.58)

1.4x10-5

(25.2)

1.57x10-5

(28.21)

1.37x10-5

(24.66)

2.0x10-5

(35.98)

Water Absorption %

24 hrs. @ 77°F (25°C)

.16 .38 .16 .20 n/a
R Valuer

Hr ft2 °F/BTU

(Hr m2 °C/Kcal)

0.09-0.23

(0.018-0.046)

1.075-0.19

(0.015-0.038)

0.09-0.23

(0.018-0.046)

0.075-0.19

(0.015-0.038)

0.10-0.26

(.02-.056)

Taber Abrasion Resistance

% max. wt. loss (CS-17 wheels, 1000 g. wt., 25 cycles)

.038 n/a .038 n/a n/a
Frontside ID Thread two n/a one n/a n/a
Thread on the Backside® red and blue n/a black n/a n/a
Sizes 2'x2' (.6m x .6m)

2'x4' (.6mx1.2m)

4'x8' (1.2mx2.4m)

4'x9' (1.2mx2.7m)

4'x10' (1.2mx3.0m)

4'x12' (1.2mx3.7m)

4'x8' (1.2mx2.4m)

4'x9' (1.2mx2.7m)

4'x10' (1.2mx3.0m)

4'x12' (1.2x3.7m)

4'x8' (1.2mx2.4m)

4'x9' (1.2mx2.7m)

4'x10' (1.2mx3.0m)

4'x12' (1.2mx3.7m)

4'x8' (1.2mx2.4m)

4'x9' (1.2mx2.7m)

4'x10' (1.2mx3.0m)

4'x12' (1.2mx3.7m)

2'x2' (.6mx6m)

2'x4' (.6mx1.27m)

(1) FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS

The numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Kemlite products or any other material under actual fire conditions. These ratings are determined by small-scale tests conducted by Underwriter's Laboratories and other independent testing facilities using the American Society for Testing and Materials E-84 test standard (commonly referred to as the "Tunnel Test:). KEMLITE PROVIDES THESE RATINGS FOR MATERIALS COMPARISON PURPOSES ONLY.

Like other organic building materials  (e.g. wood), panels made of fiberlass reinforced plastic will burn. When ignited, frp may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems, as well as precautions during constructions and occupancy. Local codes, insurance requirements and any special needs of the product user will determine the correct fire-rated interior finish and fire-suppression system necessary for a specific installation.

KEMLITE, GLASBORD, SURFASEAL, SANIGRID, KEMPLY, THREADS ON THE BACK are registered trademarks of Kemlite Company.

Request for Information / Request a Catalog from Kemlite Company
 
 
 
To request more information from Kemlite Company, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2009 AECinfo.com