| SECTION 09986 SANITARY WALL FINISH
KEMLITE® FIBERGLASS
REINFORCED PLASTIC PANELS. PART 1:
GENERAL
1.01 DESCRIPTION
This section describes the requirements for furnishing and
installing fiberglass reinforced plastic panels according to manufacturer's
recommendations.
1.02 SUBMITTALS:
Submit in accordance with Section (Insert Section
Number)
- Two samples of each type of panel each type of trim and
fastener.
- Shop Drawings: Indicate the location and dimension of joints
and fastener attachment.
- Installation Guide #6211.
1.03 QUALITY ASSURANCE
Provide panels and molding only from the manufacturer
specified to ensure warranty and color harmonization of accessories.
1.04 DELIVERY, STORAGE, AND HANDLING:
- Delivery of Materials: Package sheets on skids or pallets
for shipment to project site.
- Storage of Materials: Store panels indoors in a dry place at
the project site.
- Handling: Remove foreign matter from face of panel by use of
a soft bristle brush, avoiding abrasive action.
1.05 PROJECT CONDITIONS:
- Installation shall not begin until building is enclosed,
permanent heating and cooling equipment is in operation, and residual moisture from
plaster, concrete or terrazzo work has dissipated
- During installation and for not less than 48 hours before,
maintain an ambient temperature and relative humidity within limits required by type of
adhesive used and recommendation adhesive manufacturer.
- Provide ventilation to disperse fumes during application of
adhesive as recommended by the adhesive manufacturer.
|