| SECTION 09986 SANITARY WALL FINISH KEMLITE® FIBERGLASS
REINFORCED PLASTIC PANELS. PART 2: PRODUCTS
2.01 MATERIALS
- Acceptable panels: (Insert from Item 1,2,3 or 4 Part
A.)
- Division Bars, Corner Trim: Panel manufacturer's standard
length extruded vinyl pieces; longest length possible - to eliminate end joints (Insert
from Item 1,2,3, or 4 Part B)
- Fasteners: Non-corrosive drive rivets. (Insert from
Item 1,2, or 3 Part C.)
PART 3: EXECUTION
3.01 PREPARATION
- Examine backup surfaces to determine that corners are plumb
and straight, surfaces are smooth, uniform, clean and free from foreign matter, nails
countersunk, joints and cracks filled flush and smooth with the adjoining surface.
- Do not begin installation until backup surfaces are put into
satisfactory condition.
3.02 APPLICATION
- Do all cutting and drilling with carbide tipped saw blades
or drill bits, or cut with snips.
|
- Install panels with manufacturer's recommended gap for panel
field and corner joints.
|
- Fastener holes in the panels must be predrilled 1/8"
(3.2 mm) oversize.
|
- For trowel type and application of adhesive, follow adhesive
manufacturers recommendation.
|
- Using products acceptable to manufacturer, install the frp
panel system in accordance with panel manufacturer's printed instructions, Installation
Guide #6211.
|
3.03 CLEANING.
- Remove any adhesive or excessive sealant from panel face
using solvent or cleaner recommended by panel manufacturer.
Kemlite, are registered trademarks of Kemlite Company, Inc. |