  Kemlite Company   Glasbord  

Glasbord - Page 7

   

Glasbord

ATTACHMENT ITEM 1

Product Specifications -- Fire-X Glasbord® Fiberglass Panels with Surfaseal®

PART 2: PRODUCTS

2.01 MATERIALS:

  1. Class I (A) Interior Finish. Wall and/or ceiling panels shall be KEMLITE® Fire-X Glasbord with Surfaseal fiberglass reinforced plastic panels as manufactured by KEMLITE COMPANY, Joliet, Illinois, USA

Phone: 1-800-435-0080 or 1-815-467-8600, Fax: 1-815-467-8666.

  1. WALL PANELS

Finish, thickness and color to be: (choose one of the following)

  1. embossed .09" (2.3mm) Fire-X Glasbord with Surfaseal

color: 85 white

70 soft beige

48 pearl gray

66 silver

84 ivory

  1. embossed. 12" (3.0mm) Fire-X Glasbord with Surfaseal

color: 85 white

  1. smooth .075" (1.9mm) Glasbord-FSI with Surfaseal

color: 85 white

  1. LAY-IN CEILING PANELS

Finish, thickness and color to be: (choose one of the following)

  1. embossed .09" (2.3mm) Fire-X Glasbord with Surfaseal

color: 85 white

  1. embossed .12" (3.0mm) Fire-X Glasbord with Surfaseal

color: 85 white

Alternate products shall meet or exceed the following Fire-X Glasbord properties:

  1. Underwriter's Laboratories (UL.) Classified - embossed FXI .09" (2.3mm) only.
  1. Class A Flame Spread of less than 25, Smoke Developed less than 450 per ASTM-E84 latest version.
  1. Barcol Hardness (scratch resistance) of 55 as per ASTM D-2583
  1. Panels with exhibit no more than a 0.038% weight loss after a 25-cycle Taber Abrasion Test using CS-17 abrasive wheels with 1000 g. wt.
  1. Gardner Impact Strength of 22 in. - lbs. (25.6 cm - kg) showing no visible damage on front side per ASTM D-3029.
  1. FMRC (Factory Mutual Research Center) approved. Subject to the conditions of approval as described in FMRC Report J.I. IV549.AM-embossed FXI .09" only.
  1. Meets USDA / FSIS Requirements.
  1. ICBO Report Number 4583.
  1. A means of frontside identification and confirmation of meeting Class I (A) interior finish requirements after installation and while in service (without labels)-embossed FXI only.

Numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Kemlite Company products or any other materials under actual fire conditions. These ratings are determined by small scale tests conducted by independent testing facilities using the American society for Testing and Materials E-84 test standard (commonly referred to as the "Tunnel Test"). KEMLITE PROVIDES THESE RATINGS FOR MATERIAL COMPARISON PURPOSES ONLY. Like other organic building materials (e.g. wood), panels made of fiberglass reinforced plastic will burn. When ignited, frp may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems. as well as precaustions during construction and occupancy. Local codes, insurance requirements and any special needs of the user of the product will determine the correct fire-rated interior finish and fire suppression system necessary for a specific installation.