| ATTACHMENT ITEM 1 Product Specifications -- Fire-X Glasbord® Fiberglass Panels with Surfaseal®
PART 2: PRODUCTS
2.01 MATERIALS:
- Class I (A) Interior Finish. Wall and/or ceiling panels
shall be KEMLITE® Fire-X Glasbord with Surfaseal fiberglass reinforced plastic panels as
manufactured by KEMLITE COMPANY, Joliet, Illinois, USA
Phone: 1-800-435-0080 or 1-815-467-8600, Fax:
1-815-467-8666.
- WALL PANELS
Finish, thickness and color to be: (choose one of the
following)
- embossed .09" (2.3mm) Fire-X Glasbord with Surfaseal
color: 85 white
70 soft beige
48 pearl gray
66 silver
84 ivory
- embossed. 12" (3.0mm) Fire-X Glasbord with Surfaseal
color: 85 white
- smooth .075" (1.9mm) Glasbord-FSI with Surfaseal
color: 85 white
- LAY-IN CEILING PANELS
Finish, thickness and color to be: (choose one of the
following)
- embossed .09" (2.3mm) Fire-X Glasbord with Surfaseal
color: 85 white
- embossed .12" (3.0mm) Fire-X Glasbord with Surfaseal
color: 85 white
Alternate products shall meet or exceed the following
Fire-X Glasbord properties:
- Underwriter's Laboratories (UL.) Classified - embossed FXI
.09" (2.3mm) only.
|
- Class A Flame Spread of less than 25, Smoke Developed less
than 450 per ASTM-E84 latest version.
|
- Barcol Hardness (scratch resistance) of 55 as per ASTM
D-2583
|
- Panels with exhibit no more than a 0.038% weight loss after
a 25-cycle Taber Abrasion Test using CS-17 abrasive wheels with 1000 g. wt.
|
- Gardner Impact Strength of 22 in. - lbs. (25.6 cm - kg)
showing no visible damage on front side per ASTM D-3029.
|
- FMRC (Factory Mutual Research Center) approved. Subject to
the conditions of approval as described in FMRC Report J.I. IV549.AM-embossed FXI
.09" only.
|
- Meets USDA / FSIS Requirements.
|
- ICBO Report Number 4583.
|
- A means of frontside identification and confirmation of
meeting Class I (A) interior finish requirements after installation and while in service
(without labels)-embossed FXI only.
|
Numerical flame spread and smoke development ratings
are not intended to reflect hazards presented by Kemlite Company products or any other
materials under actual fire conditions. These ratings are determined by small scale tests
conducted by independent testing facilities using the American society for Testing and
Materials E-84 test standard (commonly referred to as the "Tunnel Test").
KEMLITE PROVIDES THESE RATINGS FOR MATERIAL COMPARISON PURPOSES ONLY. Like other organic
building materials (e.g. wood), panels made of fiberglass reinforced plastic will burn.
When ignited, frp may produce dense smoke very rapidly. All smoke is toxic. Fire safety
requires proper design of facilities and fire suppression systems. as well as precaustions
during construction and occupancy. Local codes, insurance requirements and any special
needs of the user of the product will determine the correct fire-rated interior finish and
fire suppression system necessary for a specific installation. |