| ATTACHMENT ITEM 2 Product Specifications -- Glasbord® -P Fiberglass Panels with Surfaseal®
PART 2: PRODUCTS
2.01 MATERIALS:
- Class III (C) Interior Finish. Wall and/or ceiling panels
shall be KEMLITE® Glasbord with Surfaseal fiberglass reinforced plastic panels as manufactured by
KEMLITE COMPANY, Joliet, Illinois, USA
Phone: 1-800-435-0080 or 1-815-467-8600, Fax:
1-815-467-8666.
- WALL PANELS
Finish, thickness and color to be: (choose one of the
following)
- embossed .09" (2.3mm) Glasbord-P with Surfaseal
color: 85 white
83 colonial white
70 soft beige
48 pearl gray
66 silver
84 ivory
- embossed .12" (3.0mm) Glasbord-PWI with Surfaseal
color: 85 white
- smooth .075" (1.9mm) Glasbord-PSI Glasbord-PSI with Surfaseal
color: 85 white
- LAY-IN CEILING PANELS
Finish, thickness and color to be: (choose one of the
following)
- embossed .10" (2.5mm) Glasbord-CGI with Surfaseal
color: 85 white
- embossed .12" (3.0mm) Glasbord-PWI with Surfaseal
color: 85 white
Alternate products shall meet or exceed the following
Glasbord properties:
- Class C Flame Spread of 200 or less, Smoke Developed of 450
or lower per ASTM E-84 latest version.
- Barcol Hardness (scratch resistance) per ASTM D-2583 of:
- 42 for embossed .09" (2.3mm) Glasbord-P
- 55 for embossed .12" (3.0mm) Glasbord-PWI
- 55 for smooth .075" (1.9mm) Glasbord-PSI
- 60 for embossed .10" (2.5mm) Glasbord-CGI
- Panels will exhibit no more than a 0.038% weight loss after
a 25-cycle Taber Abrasion Test using CS-17 abrasive wheels with 1000 g. wt.
- Gardner Impact Strength of 16 in. - lbs. (19 cm - kg) with
no visible damage to front side for Glasbord-P and Glasbord-CGI, and 18 in. - lbs. (21 cm
- kg) for Glasbord PSI per ASTM D-3029
- Meets USDA / FSIS Requirements.
- ICBO Report Number 4583.
- A means of frontside identification and confirmation of
meeting Class III (C) the interior finish requirement after installation and while in
service (without labels) - embossed panels only.
Numerical flame spread and smoke development ratings
are not intended to reflect hazards presented by Kemlite Company products or any other
material under actual fire conditions. These ratings are determined by small scale tests
conducted by independent testing facilities using the American Society for Testing and
Materials E-84 test standard (commonly referred to as the "Tunnel Test"). |