...EXPERIENCE
+ EXPERTISE =EXCELLENCE |
Over 35 years of unsurpassed
quality manufacturing for the building construction and fire protection equipment
industries
Multiple company-owned, full
service production facilities - Minneapolis, Minnesota and Ft. Lauderdale, Florida
Active participation in
industry professional organizations such as Construction Specifications Institute,
American Institute of Architects, and National Association of Fire Equipment Distributors
The most complete product
line in the industry continues to grow through constant innovation - fire-rated cabinets,
access panels, detention cabinets and a full line of all-aluminum cabinets
Larsen's uniquely combines
the flexibility and speed of a small company with the resources and strength of a large
organization
World-wide distributor
network-call 1-800-LARSENS (800-527-7367) or Sweet's Buyline for further information
COMPLETE PRODUCT LINE Wide
selection of architectural products, including Fire Extinguishers and Fire
Extinguisher Cabinets, Section 10520; Detention Equipment, Section 11190; and, Standpipe
and Hose Systems, Section 15375.
THREE PART
SPECIFICATION GUIDE
SECTION 080305
PART 1: GENERAL
1.01 DESCRIPTION
Bidding requirements,
conditions of the contract and pertinent portions of sections in Division One of these
specifications, apply to the section as fully as though repeated herein.
Work under this section
includes furnishing and installing access panels.
Related work:
Section (
), opening in concrete.
Section (
), opening in masonry.
Section (
), opening in partitions.
Section (
), opening in ceilings.
Section (09900), painting;
field paint finish.
1.02 SUBMITTALS
Submit product data under
provisions of Section 01300, 01340.
Include sizes, types,
finishes, scheduled locations, and details of adjoining work.
Submit manufacturer's under
provisions of Section 01300, 01340.
1.03 DELIVERY
Package, handle, deliver and
store access panels at the project site in a manner that will avoid damage.
1.04 QUALITY ASSURANCE
Manufacturer's Fire-Rated
Access Doors and frames to conform to U.L. and Warnock Hersey Requirements.
PART 2: PRODUCTS
2.01 MANUFACTURER
Access Panels listed as
follows as provided by:
Larsen's
Manufacturing Company
7421 Commerce Lane
N.E. Minneapolis, MN 55432 (612) 571-1181
2.02 MATERIAL -
Refer to manufacturer's specification data for specific design criteria.
L-FRAP/L-FRAPSS:
1. U.L. Laboratories: 1-1/2
hour rated for two hour wall systems, calls B, heat transmission less than 250 degrees
after 30 minutes, U.L. File No. R1306.
2. Warnock Hersey: 1 hour
combustible and three hour non-combustible ceiling/floor systems. File WHI-495-PSH-0181
and WHI-495-PSH-0182.
L-MP/L
MPSS: Multi-purpose access
panel for use in plaster, drywall and certain ceiling surfaces.
L-DWA: For installation of 5/8" sheetrock or
5/8" drywall before the board is up.
L-DWB: To be installed in sheetrock or drywall
after the board is up.
L-DWC:
Designed for flush installation in
drywall surfaces, utilizing a concealed type frame after taping and mudding.
L-LCP: Designed to provide large access openings in
suspended type "T Bar" ceiling systems, drywall ceilings and walls.
L-PSW:
For use in plaster surfaces, concealed frame with optional plaster ground.
L-APC: Recessed door pan with metal lath for plaster
surfaces.
L-CPA:
Recessed 1" door pan for acoustical tile or drywall.
L-CPB:
Recessed 1" door pan for acoustical tile or drywall.
L-DPM: Medium Security access panel for multipurpose
applications.
LDPH: High Security access panels for use in high
security areas.
2.03 FABRICATION
Furnish as necessary each
access panel assembly manufactured complete with all parts reedy for installation.
PART 3: EXECUTION
3.01 INSPECTION
Verify that wall and ceiling
openings are correctly dimensioned to receive walls.
3.02 INSTALLATION
Install according to
manufacturers instruction.
3.03 ADJUST AND CLEAN
Adjust latch and lock
mechanisms to operate smoothly.
WARRANTY:
All Larsen's products are warranted. Please contact factory for specific details.
Larsen's reserves the right to make engineering changes, substitutions or other
modifications without notice.
CALL 1-800-LARSENS / FAX (612) 571-6900 |