Apex 55 Asymmetry 1
T8 - Direct / Indirect |
PHOTOMETRY
| OPTICAL SETTING A:Lower wall brightness plus maximum
uniformity on wall |

|
| Report # |
2100605 |
| Efficiency |
56.2% |
| Peak Candela Value |
900 @ 125° |
| Peak : Zenith Ratio |
3.8:1 |
| Asymmetric Effectiveness |
49.2% |
| OPTICAL SETTING B: |
| Higher wall brightness with
maximum efficiency & more backlight |

|
| Report # |
2100606 |
| Efficiency |
72.9% |
| Peak Candela Value |
888 @ 127.5° |
| Peak : Zenith Ratio |
1.8:1 |
| ASYMMETRIC EFFECTIVENESS |
54.8% |
| CANDELA
DISTRIBUTION |
| Vert.
Angle |
Horizontal
Angle |
Zonal
Lumens |
| 0
|
45 |
90 |
135 |
180 |
| 0 |
4 |
4 |
4 |
4 |
4 |
|
| 5 |
4 |
4 |
4 |
4 |
4 |
0 |
| 15 |
4 |
4 |
4 |
2 |
2 |
0 |
| 25 |
4 |
4 |
3 |
2 |
2 |
0 |
| 35 |
2 |
2 |
2 |
0 |
2 |
0 |
| 45 |
1 |
0 |
0 |
0 |
0 |
0 |
| 55 |
0 |
0 |
0 |
0 |
0 |
0 |
| 65 |
0 |
0 |
0 |
0 |
0 |
0 |
| 75 |
0 |
0 |
0 |
0 |
0 |
0 |
| 85 |
0 |
0 |
0 |
0 |
0 |
0 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
222 |
209 |
8 |
7 |
7 |
103 |
| 105 |
715 |
543 |
39 |
24 |
28 |
262 |
| 115 |
837 |
644 |
79 |
33 |
37 |
299 |
| 125 |
900 |
638 |
119 |
45 |
42 |
291 |
| 135 |
828 |
609 |
156 |
71 |
55 |
249 |
| 145 |
731 |
526 |
188 |
106 |
84 |
195 |
| 155 |
566 |
434 |
210 |
143 |
123 |
133 |
| 165 |
412 |
345 |
228 |
183 |
168 |
75 |
| 175 |
284 |
267 |
237 |
221 |
216 |
24 |
| 180 |
238 |
238 |
238 |
238 |
238 |
|
CANDELA DISTRIBUTION
| Vert.
Angle |
Horizontal
Angle |
Zonal
Lumens |
| 0
|
45 |
90 |
135 |
180 |
| 0 |
2 |
2 |
2 |
2 |
2 |
|
| 5 |
2 |
2 |
2 |
2 |
2 |
0 |
| 15 |
2 |
2 |
2 |
2 |
0 |
0 |
| 25 |
2 |
2 |
2 |
0 |
0 |
0 |
| 35 |
0 |
0 |
0 |
0 |
2 |
0 |
| 45 |
0 |
0 |
0 |
0 |
0 |
0 |
| 55 |
0 |
0 |
0 |
0 |
0 |
0 |
| 65 |
0 |
0 |
0 |
0 |
0 |
0 |
| 75 |
0 |
0 |
0 |
0 |
0 |
0 |
| 85 |
0 |
0 |
0 |
0 |
0 |
0 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
190 |
189 |
15 |
5 |
3 |
93 |
| 105 |
646 |
510 |
75 |
25 |
22 |
256 |
| 115 |
790 |
642 |
161 |
85 |
60 |
327 |
| 125 |
886 |
683 |
244 |
159 |
128 |
361 |
| 135 |
869 |
701 |
322 |
239 |
207 |
350 |
| 145 |
827 |
662 |
389 |
320 |
289 |
304 |
| 155 |
717 |
619 |
441 |
393 |
368 |
232 |
| 165 |
623 |
564 |
479 |
453 |
439 |
144 |
| 175 |
526 |
514 |
498 |
489 |
486 |
49 |
| 180 |
499 |
499 |
499 |
499 |
499 |
|
| COEFFICIENTS
OF UTILIZATION (%) |
| Ceiling
Wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
53 |
53 |
53 |
53 |
46 |
46 |
46 |
31 |
31 |
31 |
0 |
| 1 |
49 |
46 |
44 |
42 |
41 |
40 |
38 |
27 |
26 |
25 |
0 |
| 2 |
44 |
40 |
37 |
35 |
38 |
34 |
32 |
24 |
22 |
21 |
0 |
| 3 |
40 |
35 |
32 |
29 |
34 |
30 |
27 |
21 |
19 |
17 |
0 |
| 4 |
37 |
31 |
27 |
24 |
31 |
27 |
23 |
18 |
16 |
14 |
0 |
| 5 |
33 |
27 |
23 |
20 |
28 |
24 |
20 |
16 |
14 |
12 |
0 |
| 6 |
31 |
24 |
20 |
17 |
26 |
21 |
17 |
14 |
12 |
10 |
0 |
| 7 |
28 |
22 |
18 |
15 |
24 |
19 |
15 |
13 |
11 |
9 |
0 |
| 8 |
26 |
20 |
16 |
13 |
22 |
17 |
13 |
11 |
9 |
8 |
0 |
| 9 |
24 |
18 |
14 |
11 |
20 |
15 |
12 |
10 |
8 |
7 |
0 |
| 10 |
22 |
16 |
12 |
10 |
19 |
14 |
11 |
9 |
8 |
6 |
0 |
Based on a floor reflectance of 0.2
| COEFFICIENTS
OF UTILIZATION (%) |
| Ceiling
Wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
69 |
69 |
69 |
69 |
59 |
59 |
59 |
40 |
40 |
40 |
0 |
| 1 |
63 |
60 |
57 |
55 |
53 |
51 |
49 |
35 |
34 |
33 |
0 |
| 2 |
57 |
52 |
48 |
45 |
49 |
45 |
41 |
30 |
28 |
27 |
0 |
| 3 |
52 |
46 |
41 |
37 |
44 |
39 |
35 |
27 |
24 |
22 |
0 |
| 4 |
47 |
40 |
35 |
31 |
40 |
34 |
30 |
24 |
21 |
19 |
0 |
| 5 |
43 |
35 |
30 |
26 |
37 |
30 |
26 |
21 |
18 |
16 |
0 |
| 6 |
40 |
32 |
26 |
22 |
34 |
27 |
23 |
19 |
16 |
14 |
0 |
| 7 |
36 |
28 |
23 |
19 |
31 |
24 |
20 |
17 |
14 |
12 |
0 |
| 8 |
34 |
25 |
20 |
17 |
28 |
22 |
17 |
15 |
12 |
10 |
0 |
| 9 |
31 |
23 |
18 |
14 |
26 |
20 |
15 |
13 |
11 |
9 |
0 |
| 10 |
29 |
21 |
16 |
13 |
24 |
18 |
14 |
12 |
10 |
8 |
0 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Optical system constructed of highly specular aluminum
to produce a direct/indirect distribution. Aluminum parabolic louver shall have 16 cells
per 4 ft to produce 55 degree cutoff in all zones.
Row ends:
Mitered aluminum extrusion end caps.
Joints & Intersections:
All joints shall be accomplished using
QuickLock joining system. Optional intersections in "L",
"T", or "x" configurations, shall be mitered aluminum extrusion.
Mounting:
Brackets attach to existing structure anywhere behind
fixture. Fully adjust-able mounting brackets to provide up to 1/8" wall variance and
allow for certical fixture leveling.
Electrical:
All luminaire sections shall be factory pre-wired to
section ends. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start, instant start or dimming.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostatically applied
meeting AAMA 603.8. Available in Ledalite standard white and in a full architectural
spectrum of colors. Medium gloss finish as standard.
*Asymmetric effectiveness refers to the percentage
of lamp lumens distributed on the room side of the luminaire, above 90 degrees.

©1996 Ledalite
Architectural Products Inc. 9087A - 198th Street, Langley, B.C., Canada, V1M 3B1 Phone:
604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Email:
info@ledalite.com WWW: http://www.ledalite.com
This sheet is available on disk or at our Web site, referenced by Catalog number. Note:
Specifications subject to change without notice. |