A+ Classroom Lighter |
3 T8 - Direct/Indirect |
 |
| Report# 2100718 |
Efficiency 89.4% |
| Vert. Angle |
Horizontal Angle |
Zonal
Lumens |
| 0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
1240 |
1240 |
1240 |
1240 |
1240 |
|
| 5 |
1230 |
1234 |
1230 |
1235 |
1236 |
119 |
| 15 |
1140 |
1156 |
1158 |
1176 |
1168 |
325 |
| 25 |
983 |
1004 |
977 |
1004 |
1003 |
457 |
| 35 |
800 |
813 |
783 |
864 |
930 |
519 |
| 45 |
593 |
592 |
636 |
678 |
690 |
488 |
| 55 |
370 |
384 |
399 |
419 |
390 |
352 |
| 65 |
169 |
193 |
196 |
190 |
201 |
195 |
| 75 |
90 |
98 |
102 |
116 |
117 |
111 |
| 85 |
25 |
34 |
36 |
40 |
39 |
41 |
| 90 |
4 |
11 |
12 |
14 |
14 |
|
| 95 |
55 |
194 |
165 |
167 |
151 |
189 |
| 105 |
239 |
525 |
668 |
749 |
727 |
625 |
| 115 |
450 |
652 |
968 |
1087 |
1126 |
863 |
| 125 |
645 |
771 |
1112 |
1357 |
1377 |
945 |
| 135 |
823 |
901 |
1093 |
1311 |
1416 |
855 |
| 145 |
975 |
1016 |
1117 |
1226 |
1285 |
705 |
| 155 |
1093 |
1119 |
1151 |
1204 |
1233 |
536 |
| 165 |
1171 |
1185 |
1194 |
1209 |
1216 |
338 |
| 175 |
1216 |
1218 |
1217 |
1218 |
1221 |
118 |
| 180 |
1221 |
1221 |
1221 |
1221 |
1221 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50 |
0 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| RCR |
|
|
|
|
|
|
|
|
|
|
|
| 0 |
92 |
92 |
92 |
92 |
83 |
83 |
83 |
66 |
66 |
66 |
30 |
| 1 |
84 |
81 |
77 |
74 |
76 |
73 |
70 |
58 |
56 |
55 |
25 |
| 2 |
77 |
71 |
66 |
61 |
69 |
64 |
60 |
51 |
48 |
46 |
22 |
| 3 |
70 |
62 |
56 |
51 |
63 |
56 |
51 |
46 |
42 |
39 |
19 |
| 4 |
64 |
55 |
49 |
43 |
58 |
50 |
44 |
41 |
36 |
33 |
16 |
| 5 |
59 |
49 |
42 |
37 |
53 |
45 |
39 |
36 |
32 |
29 |
14 |
| 6 |
54 |
44 |
37 |
32 |
49 |
40 |
34 |
33 |
28 |
25 |
13 |
| 7 |
50 |
40 |
33 |
28 |
45 |
36 |
30 |
30 |
25 |
22 |
11 |
| 8 |
47 |
36 |
29 |
25 |
42 |
33 |
27 |
27 |
23 |
19 |
10 |
| 9 |
43 |
33 |
26 |
22 |
39 |
30 |
24 |
25 |
20 |
17 |
9 |
| 10 |
40 |
30 |
24 |
20 |
36 |
28 |
22 |
23 |
18 |
16 |
8 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Highly reflective optical system designed to produce a
direct/ indirect distribution. White louver shall have 10 cells per 4ft.
Row ends:
Flat endplates (factory installed).
Jointing:
All joints shall be accomplished using QuickLock joining
system.
Mounting:
All mounts shall have vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
accept loads up to 1000lbs.
Electrical:
All luminaire sections shall be factory pre-wired to
section ends, utilizing segregated raceways.
Ballast:
Electronic: <20% THD instant start.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostatically applied, meeting
AAMA 603.8. Available in Ledalite standard white, medium gloss finish.

©1998 Ledalite Architectural Products
Inc. 6208 South 231 Street, Kent, Washington, USA 98032
Phone: 604-888-6811 Toll Free Fax:
1-800-665-LEDA (5332) Email: info@ledalite.com
WWW: http://www.ledalite.com
Note: Specifications subject to change without
notice. |