Specification Data |
Euro 55 12" |
2226T01__N or D |
1T8 |
PHOTOMETRY
Variable Optics Setting N:
72% Up 28% Down

| Efficiency |
89.9% |
| Peak Candela Value |
561 @ 107.5° |
| Peak : Zenith Ratio |
1.5:1 |
CANDELA DISTRIBUTION
Vert. Angle |
Horizontal |
Zonal Lumens |
| 0 |
22.5 |
45 |
67.5 |
90 |
| 0 |
300 |
300 |
300 |
300 |
300 |
|
| 5 |
297 |
298 |
300 |
300 |
301 |
29 |
| 15 |
282 |
291 |
325 |
362 |
376 |
94 |
| 25 |
254 |
297 |
402 |
493 |
523 |
185 |
| 35 |
207 |
282 |
451 |
581 |
621 |
260 |
| 45 |
76 |
140 |
306 |
213 |
189 |
151 |
| 55 |
1 |
8 |
24 |
10 |
11 |
17 |
| 65 |
0 |
0 |
0 |
0 |
4 |
1 |
| 75 |
0 |
0 |
0 |
0 |
0 |
0 |
| 85 |
0 |
0 |
0 |
0 |
0 |
0 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
4 |
113 |
129 |
133 |
130 |
127 |
| 105 |
52 |
155 |
356 |
503 |
542 |
334 |
| 115 |
114 |
186 |
344 |
486 |
535 |
333 |
| 125 |
176 |
227 |
331 |
436 |
484 |
298 |
| 135 |
235 |
265 |
340 |
407 |
429 |
260 |
| 145 |
287 |
298 |
350 |
396 |
410 |
219 |
| 155 |
328 |
332 |
353 |
380 |
389 |
164 |
| 165 |
356 |
359 |
357 |
364 |
365 |
103 |
| 175 |
368 |
370 |
370 |
372 |
371 |
36 |
| 180 |
371 |
371 |
371 |
371 |
371 |
|
COEFFICIENTS OF UTILIZATION (%)
Ceiling
wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
92 |
92 |
92 |
92 |
82 |
82 |
82 |
64 |
64 |
64 |
25 |
| 1 |
84 |
81 |
78 |
75 |
75 |
73 |
70 |
57 |
55 |
54 |
23 |
| 2 |
77 |
72 |
67 |
63 |
69 |
64 |
60 |
51 |
48 |
46 |
21 |
| 3 |
71 |
64 |
58 |
53 |
64 |
57 |
53 |
46 |
42 |
40 |
18 |
| 4 |
65 |
57 |
50 |
46 |
59 |
51 |
46 |
41 |
37 |
34 |
17 |
| 5 |
60 |
51 |
44 |
39 |
54 |
46 |
40 |
37 |
33 |
30 |
15 |
| 6 |
55 |
46 |
39 |
34 |
50 |
41 |
36 |
33 |
29 |
26 |
13 |
| 7 |
51 |
41 |
35 |
30 |
46 |
37 |
32 |
30 |
26 |
23 |
12 |
| 8 |
48 |
37 |
31 |
26 |
43 |
34 |
28 |
28 |
24 |
21 |
11 |
| 9 |
44 |
34 |
28 |
23 |
40 |
31 |
26 |
25 |
21 |
18 |
10 |
| 10 |
41 |
31 |
25 |
21 |
37 |
28 |
23 |
23 |
19 |
16 |
9 |
Based on a floor reflectance of 0.2
Variable Optics Setting D:
40% Up 60% Down

| Efficiency |
80.0% |
| Peak Candela Value |
315 @ 122.5° |
| Peak : Zenith Ratio |
1.6:1 |
CANDELA DISTRIBUTION
Vert. Angle |
Horizontal
Angle |
Zonal Lumens |
| 0 |
22.5 |
45 |
67.5 |
90 |
| 0 |
735 |
735 |
735 |
735 |
735 |
|
| 5 |
740 |
741 |
746 |
746 |
745 |
74 |
| 15 |
755 |
790 |
855 |
877 |
872 |
236 |
| 25 |
658 |
754 |
899 |
963 |
954 |
392 |
| 35 |
423 |
583 |
778 |
847 |
830 |
433 |
| 45 |
134 |
247 |
424 |
350 |
270 |
236 |
| 55 |
4 |
13 |
39 |
21 |
13 |
30 |
| 65 |
0 |
0 |
0 |
0 |
3 |
2 |
| 75 |
0 |
0 |
0 |
0 |
0 |
0 |
| 85 |
0 |
0 |
0 |
0 |
0 |
0 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
0 |
38 |
42 |
36 |
32 |
41 |
| 105 |
26 |
76 |
140 |
191 |
203 |
134 |
| 115 |
64 |
81 |
185 |
246 |
268 |
170 |
| 125 |
104 |
112 |
181 |
281 |
306 |
174 |
| 135 |
139 |
134 |
170 |
222 |
242 |
140 |
| 145 |
157 |
139 |
167 |
196 |
210 |
109 |
| 155 |
187 |
173 |
167 |
186 |
189 |
83 |
| 165 |
203 |
194 |
182 |
175 |
169 |
52 |
| 175 |
198 |
194 |
191 |
186 |
184 |
19 |
| 180 |
192 |
192 |
192 |
192 |
192 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
87 |
87 |
87 |
87 |
82 |
82 |
82 |
71 |
71 |
71 |
48 |
| 1 |
81 |
79 |
76 |
74 |
76 |
74 |
72 |
65 |
63 |
62 |
44 |
| 2 |
76 |
71 |
67 |
64 |
71 |
67 |
63 |
59 |
57 |
54 |
40 |
| 3 |
70 |
64 |
59 |
56 |
66 |
61 |
56 |
54 |
51 |
48 |
36 |
| 4 |
66 |
58 |
53 |
49 |
61 |
55 |
50 |
49 |
46 |
43 |
33 |
| 5 |
61 |
53 |
47 |
43 |
57 |
50 |
45 |
45 |
41 |
38 |
30 |
| 6 |
57 |
48 |
43 |
39 |
53 |
46 |
41 |
41 |
37 |
34 |
27 |
| 7 |
53 |
44 |
38 |
35 |
50 |
42 |
37 |
38 |
34 |
31 |
25 |
| 8 |
49 |
40 |
35 |
31 |
47 |
39 |
34 |
35 |
31 |
28 |
23 |
| 9 |
46 |
37 |
32 |
28 |
44 |
36 |
31 |
32 |
28 |
26 |
21 |
| 10 |
43 |
34 |
29 |
26 |
41 |
33 |
28 |
30 |
26 |
23 |
19 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Optical system constructed of highly specular aluminum to
produce a direct/indirect distribution. Aluminum
parabolic louver shall have 16 cells per 4ft to produce 55
degree cutoff in all zones.
Row ends:
Mitered aluminum extrusion end caps.
Joints & Intersections:
All joints shall be accomplished using QuickLock joining
system. Optional intersections in "L", "T", or "X"
configurations, shall be mitered aluminum extrusion.
Mounting:
All mounts shall have vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
handle loads up to 1000lbs.
Electrical:
All luminaire sections shall be factory pre-wired to
section ends, utilizing segregated raceways. Optional quick connect plugs are
available.
Ballast:
Electronic: rapid start, instant start or dimming.
Approvals:
Certified to UL & CSA standards.
Finish: Thermosetting polyester,
electrostatically applied meeting AAMA 603.8. Available in Ledalite standard white and in
a full architectural spectrum of colors. Medium gloss finish as standard.

©1996 Ledalite Architectural Products Inc.
9087A - 198th Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without
notice. |