architecture - engineering - construction
AECinfo.com
Printable version Bookmark this page Notify a colleague or friend about this page Bookmark and Share
  Ledalite Architectural Products Inc.   Minuet  

Minuet - Page 3

   

Minuet

Specification  Data Minuet 8213F01 1T5

PHOTOMETRY

CANDELA DISTRIBUTION

Vert. Angle Horizontal Angle Zonal Lumens
  0 22.5 45 67.5 90
0 0 0 0 0 0  
95 17 93 8 1 0 54
105 81 250 407 471 437 343
115 163 269 483 601 638 436
125 246 301 487 641 670 421
135 321 356 428 553 617 351
145 385 407 443 484 504 280
155 435 447 467 486 492 214
165 469 475 481 488 490 136
175 486 487 489 490 490 48
180 490 490 490 490 490  

 

COEFFICIENTS OF UTILIZATION (%)

Ceiling

Wall

RCR

80 70 50                       0
70 50 30 10 70 50 30 50 30 10 0
     
0 83 83 83 83 71 71 71 48 48 48 0
1 75 72 69 66 64 61 59 42 40 39 0
2 68 62 58 53 58 53 50 36 34 32 0
3 62 55 49 44 53 47 42 32 29 27 0
4 57 48 42 37 48 41 36 28 25 22 0
5 52 43 36 31 44 36 31 25 22 19 0
6 47 38 31 27 40 32 27 22 19 16 0
7 44 34 27 23 37 29 24 20 16 14 0
8 40 30 24 20 34 26 21 18 15 12 0
9 37 27 21 17 32 24 19 16 13 11 0
10 34 25 19 15 29 21 16 15 11 9 0

Based on a floor reflectance of 0.2


SPECIFICATIONS

Housing:

6063 T5 extruded aluminum.

Optical system:

Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to produce an indirect distribution.

Row ends:

Mitered aluminum extrusion sculptured end caps.

Joints & Intersections:

All joints shall be accomplished using TwinLock ™ joining system. Optional intersections in "L", "T", or "X" configu-rations, shall be mitered aluminum extrusion.

Mounting:

All mounts shall have tamper proof infinite vertical adjustment capability.Mounts shall be independently certified up to Zone 4 seismic requirements and able to accept loads up to 1000lb.

Electrical:

All luminaire sections shall be factory pre-wired to section ends, utilizing segregated raceways. Optional quick connect plugs are available.

Ballast:

Electronic: rapid start.

Approvals:

Certified to UL & CSA standards.

Finish:

Thermosetting polyester, electrostati-cally applied meeting AAMA 603.8. Available in Ledalite standard white and in a full architectural spectrum of colors. Medium gloss finish as standard.


©1997 Ledalite Architectural Products Inc. 9087A - 198th Street, Langley, B.C., Canada, V1M 3B1

Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Email: info@ledalite.com  WWW: http://www.ledalite.com

Note: Specifications subject to change without notice.



Request for Information / Request a Catalog from Ledalite Architectural Products Inc.
 
 
 
To request more information from Ledalite Architectural Products Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.