 |
Specification Data |
Minuet |
8213F02 |
2T5 |
PHOTOMETRY

CANDELA DISTRIBUTION
| Vert.
Angle |
Horizontal
Angle |
Zonal
Lumens |
| 0 |
22.5 |
45 |
67.5 |
90 |
| 0 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
40 |
86 |
18 |
7 |
1 |
65 |
| 105 |
176 |
471 |
533 |
489 |
448 |
462 |
| 115 |
346 |
578 |
889 |
962 |
966 |
760 |
| 125 |
516 |
633 |
1018 |
1206 |
1254 |
832 |
| 135 |
671 |
742 |
949 |
1192 |
1302 |
747 |
| 145 |
801 |
848 |
928 |
1062 |
1124 |
597 |
| 155 |
905 |
937 |
975 |
1013 |
1028 |
450 |
| 165 |
977 |
992 |
1009 |
1022 |
1028 |
284 |
| 175 |
1014 |
1018 |
1019 |
1021 |
1024 |
98 |
| 180 |
1019 |
1019 |
1019 |
1019 |
1019 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling Wall
RCR |
80 |
70 |
50
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| |
|
|
| 0 |
78 |
78 |
78 |
78 |
66 |
66 |
66 |
45 |
45 |
45 |
0 |
| 1 |
71 |
67 |
65 |
62 |
60 |
58 |
55 |
39 |
38 |
37 |
0 |
| 2 |
64 |
59 |
54 |
50 |
55 |
50 |
47 |
34 |
32 |
30 |
0 |
| 3 |
59 |
51 |
46 |
42 |
50 |
44 |
40 |
30 |
27 |
25 |
0 |
| 4 |
53 |
45 |
39 |
35 |
45 |
39 |
34 |
27 |
24 |
21 |
0 |
| 5 |
49 |
40 |
34 |
29 |
41 |
34 |
29 |
23 |
20 |
18 |
0 |
| 6 |
45 |
36 |
29 |
25 |
38 |
30 |
25 |
21 |
18 |
15 |
0 |
| 7 |
41 |
32 |
26 |
22 |
35 |
27 |
22 |
19 |
15 |
13 |
0 |
| 8 |
38 |
29 |
23 |
19 |
32 |
24 |
20 |
17 |
14 |
11 |
0 |
| 9 |
35 |
26 |
20 |
16 |
30 |
22 |
17 |
15 |
12 |
10 |
0 |
| 10 |
32 |
23 |
18 |
14 |
28 |
20 |
15 |
14 |
11 |
9 |
0 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to
produce an indirect distribution.
Row ends:
Mitered aluminum extrusion sculptured end caps.
Joints & Intersections:
All joints shall be accomplished using TwinLock joining system. Optional
intersections in "L", "T", or "X" configu-rations, shall be
mitered aluminum extrusion.
Mounting:
All mounts shall have tamper proof infinite vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
accept loads up to 1000lb.
Electrical:
All luminaire sections shall be factory pre-wired to section ends, utilizing
segregated raceways. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostatically applied meeting AAMA 603.8. Available in
Ledalite standard white and in a full architectural spectrum of colors. Medium gloss
finish as standard.

©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Email: info@ledalite.com WWW: http://www.ledalite.com
Note: Specifications subject to change without notice. |