Specification Data |
Minuet |
8213F02 |
2T5 |
PHOTOMETRY

Report #
2100565
Efficiency
80.2%
Peak Candela Value 1521 @ 135o
Peak:
1.3:1
CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle |
Zonal
Lumens |
| 0 |
22.5 |
45 |
67.5 |
90 |
| 0 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
57 |
122 |
53 |
33 |
23 |
101 |
| 105 |
224 |
548 |
643 |
639 |
600 |
572 |
| 115 |
423 |
720 |
995 |
1058 |
1069 |
870 |
| 125 |
617 |
764 |
1187 |
1353 |
1385 |
958 |
| 135 |
790 |
869 |
1144 |
1435 |
1521 |
884 |
| 145 |
939 |
985 |
1085 |
1266 |
1347 |
706 |
| 155 |
1053 |
1080 |
1123 |
1172 |
1197 |
520 |
| 165 |
1132 |
1146 |
1163 |
1180 |
1189 |
328 |
| 175 |
1177 |
1178 |
1182 |
1184 |
1188 |
114 |
| 180 |
1181 |
1181 |
1181 |
1181 |
1181 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50
0 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| RCR |
|
|
|
| 0 |
76 |
76 |
76 |
76 |
65 |
65 |
65 |
44 |
44 |
44 |
0 |
| 1 |
69 |
66 |
63 |
60 |
59 |
56 |
54 |
38 |
37 |
36 |
0 |
| 2 |
63 |
57 |
53 |
49 |
53 |
49 |
45 |
33 |
31 |
29 |
0 |
| 3 |
57 |
50 |
45 |
41 |
48 |
43 |
39 |
29 |
27 |
24 |
0 |
| 4 |
52 |
44 |
38 |
34 |
44 |
38 |
33 |
26 |
23 |
21 |
0 |
| 5 |
47 |
39 |
33 |
29 |
40 |
33 |
29 |
23 |
20 |
17 |
0 |
| 6 |
44 |
35 |
29 |
24 |
37 |
30 |
25 |
20 |
17 |
15 |
0 |
| 7 |
40 |
31 |
25 |
21 |
34 |
27 |
22 |
18 |
15 |
13 |
0 |
| 8 |
37 |
28 |
22 |
18 |
31 |
24 |
19 |
16 |
13 |
11 |
0 |
| 9 |
34 |
25 |
20 |
16 |
29 |
22 |
17 |
15 |
12 |
10 |
0 |
| 10 |
32 |
23 |
17 |
14 |
27 |
20 |
15 |
13 |
10 |
8 |
0 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to
produce an indirect distribution.
Row ends:
Mitered aluminum extrusion sculptured end caps.
Joints & Intersections:
All joints shall be accomplished using TwinLock joining system. Optional
intersections in "L", "T", or "X" configu-rations, shall be
mitered aluminum extrusion.
Mounting:
All mounts shall have tamper proof infinite vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
accept loads up to 1000lb.
Electrical:
All luminaire sections shall be factory pre-wired to section ends, utilizing
segregated raceways. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostatically applied meeting AAMA 603.8. Available in
Ledalite standard white and in a full architectural spectrum of colors. Medium gloss
finish as standard.

©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without notice. |