architecture - engineering - construction
AECinfo.com
Printable version Bookmark this page Notify a colleague or friend about this page Bookmark and Share
  Ledalite Architectural Products Inc.   Minuet  

Minuet - Page 9

   

Minuet

Specification Data Minuet 8213T01 1T8

PHOTOMETRY

Report #                             2100559
Efficiency                            80.9%
Peak Candela Value        731 @ 122.5o
Peak:Zenith Ratio                  1.3:1

CANDELA DISTRIBUTION

Vert. Angle Horizontal Angle Zonal Lumens
0 22.5 45 67.5 90
0 0 0 0 0 0  
95 17 79 45 46 36 65
105 79 280 383 369 343 319
115 160 294 532 654 685 465
125 241 304 527 677 726 446
135 316 351 466 608 672 372
145 378 399 441 513 551 286
155 428 440 458 480 488 213
165 462 468 473 480 483 135
175 480 482 481 482 482 48
180 482 482 482 482 482  

COEFFICIENTS OF UTILIZATION (%)

Ceiling 80 70 50              0
Wall 70 50 30 10 70 50 30 50 30 10 0
RCR      
0 77 77 77 77 65 65 65 45 45 45 0
1 70 66 64 61 59 57 54 39 37 36 0
2 63 58 53 50 54 49 46 34 32 30 0
3 58 51 45 41 49 43 39 30 27 25 0
4 53 45 39 34 45 38 33 26 23 21 0
5 48 39 33 29 41 34 29 23 20 18 0
6 44 35 29 25 37 30 25 21 17 15 0
7 40 31 25 21 34 27 22 18 15 13 0
8 37 28 22 18 32 24 19 17 13 11 0
9 34 25 20 16 29 22 17 15 12 10 0
10 32 23 18 14 27 20 15 14 11 9 0

Based on a floor reflectance of 0.2

SPECIFICATIONS

Housing:
6063 T5 extruded aluminum.

Optical system:
Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to produce an indirect distribution.

Row ends:
Mitered aluminum extrusion sculptured end caps.

Joints & Intersections:
All joints shall be accomplished using TwinLock ™ joining system. Optional intersections in "L", "T", or "X" configu-rations, shall be mitered aluminum extrusion.

Mounting:
All mounts shall have tamper proof infinite vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to accept loads up to 1000lb.

Electrical:
All luminaire sections shall be factory pre-wired to section ends, utilizing segregated raceways. Optional quick connect plugs are available.

Ballast:
Electronic: rapid start.

Approvals:
Certified to UL & CSA standards.

Finish:
Thermosetting polyester, electrostati-cally applied meeting AAMA 603.8. Available in Ledalite standard white and in a full architectural spectrum of  colors. Medium gloss finish as standard.

©1997 Ledalite Architectural Products Inc. 9087A - 198th Street, Langley, B.C., Canada, V1M 3B1

Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Email: info@ledalite.com  WWW: http://www.ledalite.com

Note: Specifications subject to change without notice.



Request for Information / Request a Catalog from Ledalite Architectural Products Inc.
 
 
 
To request more information from Ledalite Architectural Products Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.