Specification Data |
Minuet |
8213T02 |
2T8 |
PHOTOMETRY

CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle Lumens |
Zonal Lumens |
| 0 |
22.5 |
45 |
67.5 |
90 |
| 0 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
45 |
86 |
65 |
62 |
54 |
89 |
| 105 |
196 |
461 |
473 |
446 |
438 |
442 |
| 115 |
376 |
676 |
875 |
902 |
899 |
759 |
| 125 |
554 |
776 |
1068 |
1209 |
1250 |
881 |
| 135 |
718 |
833 |
1173 |
1355 |
1389 |
849 |
| 145 |
858 |
916 |
1124 |
1322 |
1406 |
705 |
| 155 |
969 |
1001 |
1066 |
1168 |
1229 |
503 |
| 165 |
1045 |
1063 |
1079 |
1098 |
1110 |
307 |
| 175 |
1086 |
1092 |
1093 |
1095 |
1098 |
106 |
| 180 |
1093 |
1093 |
1093 |
1093 |
1093 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50
0 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| RCR |
|
|
|
| 0 |
76 |
76 |
76 |
76 |
65 |
65 |
65 |
44 |
44 |
44 |
0 |
| 1 |
69 |
66 |
63 |
60 |
59 |
56 |
54 |
38 |
37 |
36 |
0 |
| 2 |
63 |
57 |
53 |
49 |
53 |
49 |
45 |
33 |
31 |
29 |
0 |
| 3 |
57 |
50 |
45 |
41 |
48 |
43 |
39 |
29 |
27 |
24 |
0 |
| 4 |
52 |
44 |
38 |
34 |
44 |
38 |
33 |
26 |
23 |
21 |
0 |
| 5 |
47 |
39 |
33 |
29 |
40 |
33 |
28 |
23 |
20 |
17 |
0 |
| 6 |
43 |
35 |
29 |
24 |
37 |
30 |
25 |
20 |
17 |
15 |
0 |
| 7 |
40 |
31 |
25 |
21 |
34 |
27 |
22 |
18 |
15 |
13 |
0 |
| 8 |
37 |
28 |
22 |
18 |
31 |
24 |
19 |
16 |
13 |
11 |
0 |
| 9 |
34 |
25 |
20 |
16 |
29 |
22 |
17 |
15 |
12 |
10 |
0 |
| 10 |
32 |
23 |
17 |
14 |
27 |
19 |
15 |
13 |
10 |
8 |
0 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to
produce an indirect distribution.
Row ends:
Mitered aluminum extrusion sculptured end caps.
Joints & Intersections:
All joints shall be accomplished using TwinLock joining system. Optional
intersections in "L", "T", or "X" configu-rations, shall be
mitered aluminum extrusion.
Mounting:
All mounts shall have tamper proof infinite vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
accept loads up to 1000lb.
Electrical:
All luminaire sections shall be factory pre-wired to section ends, utilizing
segregated raceways. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostati-cally applied meeting AAMA 603.8. Available in
Ledalite standard white and in a full architectural spectrum of colors. Medium gloss
finish as standard.

©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without notice. |