Specification Data |
Minuet |
8215T01 |
1T8 |
PHOTOMETRY

CANDELA DISTRIBUTION
| Vert Angle |
Horizontal Angle |
Zonal Lumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
79 |
79 |
79 |
79 |
79 |
|
| 5 |
79 |
78 |
78 |
78 |
77 |
8 |
| 15 |
74 |
75 |
75 |
74 |
73 |
21 |
| 25 |
67 |
67 |
68 |
67 |
68 |
31 |
| 35 |
59 |
59 |
59 |
59 |
59 |
36 |
| 45 |
48 |
49 |
49 |
48 |
49 |
36 |
| 55 |
35 |
36 |
37 |
37 |
38 |
33 |
| 65 |
21 |
23 |
25 |
26 |
27 |
24 |
| 75 |
8 |
11 |
13 |
12 |
12 |
13 |
| 85 |
0 |
1 |
4 |
3 |
3 |
3 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
20 |
62 |
48 |
43 |
41 |
60 |
| 105 |
77 |
207 |
368 |
347 |
335 |
290 |
| 115 |
148 |
252 |
423 |
570 |
625 |
400 |
| 125 |
222 |
281 |
432 |
545 |
591 |
373 |
| 135 |
289 |
322 |
419 |
530 |
564 |
327 |
| 145 |
347 |
366 |
409 |
471 |
502 |
263 |
| 155 |
392 |
402 |
421 |
445 |
457 |
196 |
| 165 |
424 |
430 |
433 |
441 |
446 |
124 |
| 175 |
440 |
443 |
441 |
444 |
445 |
44 |
| 180 |
443 |
443 |
443 |
443 |
443 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50
0 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| RCR |
|
|
|
| 0 |
76 |
76 |
76 |
76 |
66 |
66 |
66 |
47 |
47 |
47 |
7 |
| 1 |
69 |
66 |
63 |
61 |
60 |
57 |
55 |
41 |
40 |
38 |
6 |
| 2 |
63 |
58 |
53 |
49 |
54 |
50 |
46 |
36 |
34 |
32 |
5 |
| 3 |
57 |
50 |
45 |
41 |
50 |
44 |
40 |
32 |
29 |
26 |
4 |
| 4 |
52 |
44 |
39 |
34 |
45 |
39 |
34 |
28 |
25 |
22 |
3 |
| 5 |
48 |
39 |
33 |
29 |
41 |
34 |
29 |
25 |
21 |
19 |
3 |
| 6 |
44 |
35 |
29 |
25 |
38 |
31 |
26 |
22 |
19 |
16 |
2 |
| 7 |
40 |
31 |
26 |
21 |
35 |
27 |
22 |
20 |
16 |
14 |
2 |
| 8 |
37 |
28 |
23 |
19 |
32 |
25 |
20 |
18 |
15 |
12 |
2 |
| 9 |
34 |
25 |
20 |
16 |
30 |
22 |
18 |
16 |
13 |
11 |
1 |
| 10 |
32 |
23 |
18 |
14 |
28 |
20 |
16 |
15 |
12 |
9 |
1 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to
produce an indirect distribution.
Row ends:
Mitered aluminum extrusion sculptured end caps.
Joints & Intersections:
All joints shall be accomplished using TwinLock joining system. Optional
intersections in "L", "T", or "X" configu-rations, shall be
mitered aluminum extrusion.
Mounting:
All mounts shall have tamper proof infinite vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
accept loads up to 1000lb.
Electrical:
All luminaire sections shall be factory pre-wired to section ends, utilizing
segregated raceways. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostati-cally applied meeting AAMA 603.8. Available in
Ledalite standard white and in a full architectural spectrum of colors. Medium gloss
finish as standard.

* This
photometry is based on the L-hole perf option.
©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without notice. |