Specification Data |
Minuet |
8215T02 |
2T8 |
PHOTOMETRY

CANDELA DISTRIBUTION
| Vert Angle |
Horizontal Angle |
ZonalLumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
196 |
196 |
196 |
196 |
196 |
|
| 5 |
196 |
196 |
196 |
196 |
195 |
19 |
| 15 |
186 |
188 |
187 |
188 |
186 |
52 |
| 25 |
172 |
173 |
172 |
171 |
170 |
79 |
| 35 |
149 |
151 |
151 |
151 |
150 |
94 |
| 45 |
123 |
123 |
125 |
123 |
124 |
96 |
| 55 |
91 |
93 |
95 |
96 |
96 |
84 |
| 65 |
57 |
61 |
65 |
67 |
68 |
63 |
| 75 |
23 |
30 |
37 |
35 |
34 |
36 |
| 85 |
1 |
7 |
10 |
10 |
10 |
10 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
35 |
70 |
59 |
51 |
49 |
75 |
| 105 |
157 |
352 |
411 |
373 |
372 |
368 |
| 115 |
310 |
538 |
697 |
771 |
798 |
626 |
| 125 |
462 |
615 |
872 |
976 |
1019 |
715 |
| 135 |
600 |
675 |
947 |
1100 |
1143 |
692 |
| 145 |
720 |
754 |
897 |
1078 |
1139 |
574 |
| 155 |
811 |
832 |
877 |
951 |
987 |
412 |
| 165 |
876 |
889 |
900 |
914 |
921 |
255 |
| 175 |
913 |
917 |
917 |
920 |
924 |
89 |
| 180 |
920 |
920 |
920 |
920 |
920 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50
0 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| RCR |
|
|
|
| 0 |
73 |
73 |
73 |
73 |
64 |
64 |
64 |
46 |
46 |
46 |
9 |
| 1 |
66 |
63 |
61 |
58 |
58 |
55 |
53 |
40 |
39 |
38 |
7 |
| 2 |
60 |
55 |
51 |
47 |
52 |
48 |
45 |
35 |
33 |
31 |
6 |
| 3 |
55 |
48 |
43 |
39 |
48 |
42 |
38 |
31 |
28 |
26 |
5 |
| 4 |
50 |
43 |
37 |
33 |
43 |
37 |
33 |
27 |
24 |
22 |
4 |
| 5 |
46 |
38 |
32 |
28 |
40 |
33 |
28 |
24 |
21 |
19 |
4 |
| 6 |
42 |
34 |
28 |
24 |
36 |
29 |
25 |
22 |
18 |
16 |
3 |
| 7 |
39 |
30 |
24 |
21 |
34 |
26 |
22 |
19 |
16 |
14 |
3 |
| 8 |
36 |
27 |
22 |
18 |
31 |
24 |
19 |
17 |
14 |
12 |
2 |
| 9 |
33 |
24 |
19 |
16 |
29 |
21 |
17 |
16 |
13 |
11 |
2 |
| 10 |
31 |
22 |
17 |
14 |
27 |
20 |
15 |
14 |
11 |
9 |
2 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to
produce an indirect distribution.
Row ends:
Mitered aluminum extrusion sculptured end caps.
Joints & Intersections:
All joints shall be accomplished using TwinLock joining system. Optional
intersections in "L", "T", or "X" configu-rations, shall be
mitered aluminum extrusion.
Mounting:
All mounts shall have tamper proof infinite vertical adjustment capability.
Mounts shall be independently certified up to Zone 4 seismic requirements and able to
accept loads up to 1000lb.
Electrical:
All luminaire sections shall be factory pre-wired to section ends, utilizing
segregated raceways. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostati-cally applied meeting AAMA 603.8. Available in
Ledalite standard white and in a full architectural spectrum of colors. Medium gloss
finish as standard.

* This
photometry is based on the L-hole perf option.
©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without notice. |