Specification Data |
Minuet |
8216F02__N or D |
2T5 |
PHOTOMETRY
Variable Optics Setting N:

| Report # |
2100560 |
| Efficiency |
85.2% |
| Peak Candela Value |
1000 @ 137.5 o |
| Peak : Zenith Ratio |
1.5:1 |
CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal
Angle |
Zonal Lumens |
|
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
613 |
613 |
613 |
613 |
613 |
|
| 5 |
610 |
612 |
616 |
617 |
619 |
60 |
| 15 |
576 |
599 |
661 |
715 |
743 |
187 |
| 25 |
504 |
572 |
699 |
789 |
818 |
312 |
| 35 |
365 |
495 |
637 |
714 |
725 |
366 |
| 45 |
130 |
236 |
332 |
419 |
351 |
233 |
| 55 |
22 |
33 |
48 |
69 |
59 |
52 |
| 65 |
7 |
11 |
12 |
21 |
25 |
16 |
| 75 |
2 |
4 |
7 |
8 |
7 |
7 |
| 85 |
0 |
4 |
4 |
4 |
4 |
4 |
| 90 |
0 |
3 |
2 |
3 |
3 |
|
| 95 |
27 |
80 |
14 |
6 |
4 |
59 |
| 105 |
110 |
309 |
442 |
447 |
412 |
374 |
| 115 |
225 |
422 |
617 |
743 |
778 |
561 |
| 125 |
341 |
470 |
747 |
856 |
887 |
601 |
| 135 |
447 |
541 |
743 |
945 |
998 |
568 |
| 145 |
538 |
610 |
707 |
832 |
893 |
452 |
| 155 |
611 |
660 |
717 |
764 |
786 |
329 |
| 165 |
657 |
683 |
718 |
739 |
747 |
202 |
| 175 |
682 |
686 |
695 |
700 |
704 |
68 |
| 180 |
687 |
687 |
687 |
687 |
687 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling Wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
86 |
86 |
86 |
86 |
77 |
77 |
77 |
60 |
60 |
60 |
23 |
| 1 |
79 |
76 |
73 |
71 |
71 |
68 |
66 |
54 |
52 |
51 |
21 |
| 2 |
73 |
67 |
63 |
59 |
65 |
61 |
57 |
48 |
45 |
43 |
19 |
| 3 |
67 |
60 |
54 |
50 |
60 |
54 |
49 |
43 |
40 |
37 |
17 |
| 4 |
62 |
53 |
47 |
43 |
55 |
48 |
43 |
39 |
35 |
32 |
15 |
| 5 |
57 |
48 |
42 |
37 |
51 |
43 |
38 |
35 |
31 |
28 |
14 |
| 6 |
52 |
43 |
37 |
32 |
47 |
39 |
34 |
31 |
28 |
25 |
12 |
| 7 |
48 |
39 |
33 |
28 |
43 |
35 |
30 |
29 |
25 |
22 |
11 |
| 8 |
45 |
35 |
29 |
25 |
40 |
32 |
27 |
26 |
22 |
19 |
10 |
| 9 |
42 |
32 |
26 |
22 |
37 |
29 |
24 |
24 |
20 |
17 |
9 |
| 10 |
39 |
29 |
24 |
20 |
35 |
27 |
22 |
22 |
18 |
16 |
8 |
Based on a floor reflectance of 0.2
Variable Optics Setting D:

| Report # |
2100561 |
| Efficiency |
65.8% |
| Peak Candela Value |
430 @ 150o |
| Peak : Zenith Ratio |
1.4:1 |
CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle |
Zone Lumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
937 |
937 |
937 |
937 |
937 |
|
| 5 |
942 |
954 |
988 |
998 |
1019 |
96 |
| 15 |
906 |
989 |
1138 |
1240 |
1274 |
313 |
| 25 |
779 |
965 |
1122 |
1161 |
1153 |
484 |
| 35 |
607 |
834 |
922 |
972 |
977 |
540 |
| 45 |
216 |
359 |
512 |
634 |
589 |
366 |
| 55 |
34 |
49 |
101 |
226 |
205 |
122 |
| 65 |
10 |
13 |
15 |
40 |
39 |
27 |
| 75 |
2 |
4 |
4 |
7 |
5 |
6 |
| 85 |
0 |
0 |
0 |
0 |
0 |
1 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
19 |
44 |
23 |
17 |
10 |
35 |
| 105 |
57 |
134 |
216 |
197 |
165 |
174 |
| 115 |
110 |
184 |
280 |
364 |
371 |
260 |
| 125 |
156 |
237 |
315 |
346 |
339 |
258 |
| 135 |
213 |
280 |
351 |
361 |
381 |
248 |
| 145 |
251 |
317 |
388 |
384 |
416 |
222 |
| 155 |
286 |
315 |
353 |
378 |
412 |
162 |
| 165 |
295 |
304 |
325 |
352 |
369 |
93 |
| 175 |
314 |
315 |
321 |
322 |
328 |
32 |
| 180 |
312 |
312 |
312 |
312 |
312 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling Wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
71 |
71 |
71 |
71 |
66 |
66 |
66 |
57 |
57 |
57 |
37 |
| 1 |
66 |
64 |
62 |
60 |
62 |
60 |
58 |
52 |
51 |
49 |
34 |
| 2 |
61 |
57 |
54 |
51 |
57 |
54 |
51 |
47 |
45 |
43 |
30 |
| 3 |
57 |
51 |
47 |
44 |
53 |
48 |
45 |
42 |
40 |
38 |
27 |
| 4 |
53 |
46 |
42 |
38 |
49 |
44 |
40 |
39 |
36 |
33 |
24 |
| 5 |
49 |
42 |
37 |
34 |
45 |
40 |
35 |
35 |
32 |
29 |
22 |
| 6 |
45 |
38 |
33 |
30 |
42 |
36 |
32 |
32 |
29 |
26 |
20 |
| 7 |
42 |
35 |
30 |
27 |
39 |
33 |
29 |
29 |
26 |
23 |
18 |
| 8 |
39 |
32 |
27 |
24 |
37 |
30 |
26 |
27 |
24 |
21 |
16 |
| 9 |
37 |
29 |
25 |
21 |
34 |
28 |
23 |
25 |
21 |
19 |
15 |
| 10 |
34 |
27 |
22 |
19 |
32 |
25 |
21 |
23 |
20 |
17 |
14 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Optical system constructed of
highly specular aluminum to
produce a direct/indirect
distribution. Aluminum parabolic
louver shall have 16 cells per 4ft to
produce 55 degree cutoff in all
zones.
Row ends:
Mitered aluminum extrusion
sculptured end caps.
Joints & Intersections:
All joints shall be accomplished
using TwinLock joining system.
Optional intersections in "L", "T", or
"X" configurations, shall be mitered
aluminum extrusion.
Mounting:
All mounts shall have tamper proof
infinite vertical adjustment
capability. Mounts shall be
independently certified up to Zone
4 seismic requirements and able
to accept loads up to 1000lb.
Electrical:
All luminaire sections shall be
factory pre-wired to section ends,
utilizing segregated raceways.
Optional quick connect plugs are
available.
Ballast:
Electronic: rapid start or dimming.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester,
electrostatically applied meeting
AAMA 603.8. Available in Ledalite
standard white and in a full
architectural spectrum of colors.
Medium gloss finish as standard.

©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without notice. |