Specification Data |
Minuet |
8216T02__N or D |
2T8 |
PHOTOMETRY
Variable Optics Setting N:
| Report # |
2100542 |
| Efficiency |
85.4% |
| Peak Candela Value |
1064 @ 137.5° |
| Peak : Zenith Ratio |
1.3:1 |

CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle |
Zone Lumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
773 |
773 |
773 |
773 |
773 |
|
| 5 |
770 |
769 |
770 |
770 |
772 |
74 |
| 15 |
723 |
736 |
760 |
784 |
791 |
214 |
| 25 |
626 |
660 |
699 |
732 |
729 |
319 |
| 35 |
470 |
547 |
582 |
653 |
674 |
365 |
| 45 |
180 |
282 |
370 |
483 |
490 |
277 |
| 55 |
25 |
41 |
76 |
153 |
151 |
89 |
| 65 |
7 |
11 |
12 |
24 |
27 |
17 |
| 75 |
0 |
4 |
6 |
8 |
7 |
6 |
| 85 |
0 |
0 |
3 |
3 |
1 |
2 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
32 |
93 |
63 |
78 |
56 |
85 |
| 105 |
138 |
356 |
379 |
375 |
321 |
356 |
| 115 |
273 |
491 |
680 |
784 |
770 |
604 |
| 125 |
410 |
571 |
810 |
949 |
989 |
676 |
| 135 |
536 |
646 |
855 |
1013 |
1062 |
640 |
| 145 |
643 |
721 |
841 |
978 |
1033 |
530 |
| 155 |
728 |
781 |
839 |
896 |
930 |
388 |
| 165 |
788 |
814 |
845 |
862 |
873 |
237 |
| 175 |
819 |
823 |
830 |
832 |
839 |
81 |
| 180 |
821 |
821 |
821 |
821 |
821 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50 |
0 |
| Wall RCR |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
87 |
87 |
87 |
87 |
77 |
77 |
77 |
60 |
60 |
60 |
23 |
| 1 |
80 |
76 |
74 |
71 |
71 |
69 |
66 |
54 |
52 |
51 |
21 |
| 2 |
73 |
68 |
63 |
59 |
65 |
61 |
57 |
48 |
45 |
43 |
19 |
| 3 |
67 |
60 |
54 |
50 |
60 |
54 |
49 |
43 |
40 |
37 |
17 |
| 4 |
62 |
53 |
47 |
43 |
55 |
48 |
43 |
38 |
35 |
32 |
15 |
| 5 |
57 |
48 |
42 |
37 |
51 |
43 |
38 |
35 |
31 |
28 |
13 |
| 6 |
52 |
43 |
37 |
32 |
47 |
39 |
34 |
31 |
27 |
25 |
12 |
| 7 |
48 |
39 |
33 |
28 |
43 |
35 |
30 |
28 |
25 |
22 |
11 |
| 8 |
45 |
35 |
29 |
25 |
40 |
32 |
27 |
26 |
22 |
19 |
10 |
| 9 |
42 |
32 |
26 |
22 |
38 |
29 |
24 |
24 |
20 |
17 |
9 |
| 10 |
39 |
29 |
24 |
20 |
35 |
27 |
22 |
22 |
18 |
16 |
8 |
Based on a floor reflectance of 0.2
Variable Optics Setting D:

| Report # |
2100553 |
| Efficiency |
62.7% |
| Peak Candela Value |
495 @ 145 o |
| Peak : Zenith Ratio |
1.4:1 |
CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle |
Zone Lumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
1055 |
1055 |
1055 |
1055 |
1055 |
|
| 5 |
1051 |
1050 |
1053 |
1057 |
1064 |
104 |
| 15 |
1006 |
1024 |
1053 |
1078 |
1077 |
295 |
| 25 |
882 |
932 |
936 |
959 |
970 |
433 |
| 35 |
676 |
761 |
791 |
864 |
895 |
495 |
| 45 |
247 |
356 |
509 |
641 |
652 |
371 |
| 55 |
34 |
48 |
108 |
242 |
250 |
131 |
| 65 |
8 |
11 |
12 |
31 |
30 |
24 |
| 75 |
0 |
0 |
3 |
5 |
5 |
3 |
| 85 |
0 |
0 |
0 |
0 |
0 |
0 |
| 90 |
0 |
0 |
0 |
0 |
0 |
|
| 95 |
24 |
61 |
39 |
41 |
34 |
51 |
| 105 |
77 |
185 |
216 |
205 |
172 |
191 |
| 115 |
141 |
256 |
363 |
388 |
345 |
307 |
| 125 |
201 |
307 |
407 |
450 |
435 |
332 |
| 135 |
261 |
337 |
436 |
474 |
472 |
312 |
| 145 |
306 |
361 |
437 |
474 |
495 |
262 |
| 155 |
338 |
367 |
406 |
438 |
467 |
188 |
| 165 |
346 |
358 |
375 |
388 |
402 |
107 |
| 175 |
350 |
353 |
358 |
357 |
361 |
35 |
| 180 |
352 |
352 |
352 |
352 |
352 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling |
80 |
70 |
50 |
0 |
| Wall RCR |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| 0 |
67 |
67 |
67 |
67 |
62 |
62 |
62 |
52 |
52 |
52 |
31 |
| 1 |
62 |
60 |
58 |
56 |
57 |
55 |
54 |
47 |
46 |
45 |
29 |
| 2 |
57 |
53 |
50 |
47 |
53 |
50 |
47 |
43 |
41 |
39 |
26 |
| 3 |
53 |
48 |
44 |
41 |
49 |
45 |
41 |
39 |
36 |
34 |
23 |
| 4 |
49 |
43 |
39 |
35 |
45 |
40 |
36 |
35 |
32 |
30 |
21 |
| 5 |
45 |
39 |
34 |
31 |
42 |
36 |
32 |
32 |
29 |
26 |
19 |
| 6 |
42 |
35 |
31 |
27 |
39 |
33 |
29 |
29 |
26 |
23 |
17 |
| 7 |
39 |
32 |
27 |
24 |
36 |
30 |
26 |
26 |
23 |
21 |
15 |
| 8 |
36 |
29 |
25 |
22 |
34 |
27 |
23 |
24 |
21 |
19 |
14 |
| 9 |
34 |
27 |
22 |
19 |
32 |
25 |
21 |
22 |
19 |
17 |
12 |
| 10 |
32 |
25 |
20 |
18 |
30 |
23 |
19 |
21 |
18 |
15 |
11 |
Based on a floor reflectance of 0.2
SPECIFICATIONS
Housing: 6063 T5 extruded aluminum.
Optical system: Optical system constructed of highly
specular aluminum to produce a direct/indirect distribution. Aluminum parabolic louver
shall have 16 cells per 4ft to produce 55 degree cutoff in all zones.
Row ends: Mitered aluminum extrusion sculptured end
caps.
Joints & Intersections: All joints shall be
accomplished using TwinLock joining system. Optional intersections in "L",
"T", or "X" configurations, shall be mitered aluminum extrusion.
Mounting: All mounts shall have tamper proof
infinite vertical adjustment capability. Mounts shall be independently certified up to
Zone 4 seismic requirements and able to accept loads up to 1000lb.
Electrical: All luminaire sections shall be factory
pre-wired to section ends, utilizing segregated raceways. Optional quick connect plugs are
available.
Ballast: Electronic: rapid start or dimming.
Approvals: Certified to UL & CSA standards.
Finish: Thermosetting polyester,electrostatically
applied meeting AAMA 603.8. Available in Ledalite standard white and in a full
architectural spectrum of colors. Medium gloss finish as standard.

©1997 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com