Minuet 9" |
3 T8 - Direct / Indirect |
PHOTOMETRY (Meets RP-1)
Variable Optics Setting N:

| Report # |
2100669 |
| Efficiency |
87.6% |
| Peak Candela Value |
1473 @ 145° |
| Peak : Zenith Ratio |
1.2:1 |
CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle |
Zonal Lumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
1218 |
1218 |
1218 |
1218 |
1218 |
|
| 5 |
1214 |
1214 |
1210 |
1216 |
1214 |
118 |
| 15 |
1135 |
1156 |
1172 |
1208 |
1220 |
334 |
| 25 |
999 |
1036 |
1126 |
1201 |
1219 |
515 |
| 35 |
825 |
912 |
994 |
1089 |
1126 |
619 |
| 45 |
413 |
597 |
739 |
908 |
969 |
555 |
| 55 |
56 |
117 |
287 |
494 |
557 |
279 |
| 65 |
20 |
25 |
32 |
160 |
195 |
85 |
| 75 |
9 |
13 |
17 |
21 |
31 |
21 |
| 85 |
4 |
10 |
12 |
13 |
10 |
11 |
| 90 |
4 |
9 |
10 |
9 |
9 |
|
| 95 |
50 |
131 |
114 |
112 |
101 |
136 |
| 105 |
216 |
459 |
549 |
585 |
561 |
517 |
| 115 |
414 |
680 |
859 |
981 |
990 |
795 |
| 125 |
616 |
840 |
1083 |
1230 |
1251 |
910 |
| 135 |
803 |
963 |
1226 |
1369 |
1407 |
897 |
| 145 |
962 |
1082 |
1254 |
1415 |
1473 |
776 |
| 155 |
1091 |
1171 |
1256 |
1337 |
1393 |
579 |
| 165 |
1180 |
1219 |
1267 |
1305 |
1318 |
357 |
| 175 |
1229 |
1233 |
1241 |
1248 |
1252 |
122 |
| 180 |
1232 |
1232 |
1232 |
1232 |
1232 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling Wall RCR |
80 |
70 |
50 |
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| |
|
|
| 0 |
90 |
90 |
90 |
90 |
81 |
81 |
81 |
64 |
64 |
64 |
29 |
| 1 |
83 |
79 |
76 |
74 |
75 |
72 |
69 |
57 |
56 |
54 |
26 |
| 2 |
76 |
70 |
65 |
61 |
68 |
64 |
59 |
51 |
48 |
46 |
23 |
| 3 |
70 |
62 |
56 |
52 |
63 |
56 |
51 |
46 |
42 |
39 |
20 |
| 4 |
64 |
55 |
49 |
44 |
58 |
50 |
45 |
41 |
37 |
34 |
18 |
| 5 |
59 |
49 |
43 |
38 |
53 |
45 |
39 |
37 |
33 |
29 |
16 |
| 6 |
54 |
44 |
38 |
33 |
49 |
40 |
35 |
33 |
29 |
26 |
14 |
| 7 |
50 |
40 |
33 |
29 |
45 |
37 |
31 |
30 |
26 |
23 |
12 |
| 8 |
46 |
36 |
30 |
25 |
42 |
33 |
28 |
27 |
23 |
20 |
11 |
| 9 |
43 |
33 |
27 |
23 |
39 |
30 |
25 |
25 |
21 |
18 |
10 |
| 10 |
40 |
30 |
24 |
20 |
36 |
28 |
22 |
23 |
19 |
16 |
9 |
Based on a floor reflectance of 0.2
Variable Optics Setting D:

| Report # |
2100670 |
| Efficiency |
65.3% |
| Peak Candela Value |
562 @ 147.5° |
| Peak : Zenith Ratio |
1.2:1 |
CANDELA DISTRIBUTION
| Vert. Angle |
Horizontal Angle |
Zonal Lumens |
| |
0 |
22.5 |
45 |
67.5 |
90 |
|
| 0 |
1685 |
1685 |
1685 |
1685 |
1685 |
|
| 5 |
1679 |
1689 |
1713 |
1718 |
1733 |
168 |
| 15 |
1593 |
1682 |
1758 |
1799 |
1811 |
489 |
| 25 |
1430 |
1563 |
1652 |
1731 |
1745 |
750 |
| 35 |
1197 |
1368 |
1424 |
1524 |
1561 |
886 |
| 45 |
594 |
854 |
1033 |
1227 |
1294 |
769 |
| 55 |
79 |
157 |
385 |
678 |
734 |
378 |
| 65 |
25 |
29 |
36 |
244 |
292 |
121 |
| 75 |
9 |
11 |
13 |
16 |
30 |
20 |
| 85 |
2 |
4 |
4 |
4 |
4 |
5 |
| 90 |
2 |
4 |
4 |
4 |
4 |
|
| 95 |
28 |
55 |
41 |
48 |
39 |
55 |
| 105 |
113 |
211 |
241 |
238 |
199 |
220 |
| 115 |
205 |
303 |
382 |
413 |
388 |
343 |
| 125 |
287 |
370 |
451 |
485 |
475 |
378 |
| 135 |
357 |
415 |
495 |
532 |
535 |
364 |
| 145 |
406 |
458 |
509 |
555 |
561 |
314 |
| 155 |
445 |
486 |
514 |
530 |
539 |
234 |
| 165 |
466 |
487 |
509 |
514 |
518 |
142 |
| 175 |
469 |
470 |
476 |
476 |
479 |
47 |
| 180 |
467 |
467 |
467 |
467 |
467 |
|
COEFFICIENTS OF UTILIZATION (%)
| Ceiling Wall RCR |
80 |
70 |
50
0 |
| 70 |
50 |
30 |
10 |
70 |
50 |
30 |
50 |
30 |
10 |
0 |
| |
|
|
| 0 |
72 |
72 |
72 |
72 |
67 |
67 |
67 |
59 |
59 |
59 |
41 |
| 1 |
67 |
64 |
62 |
60 |
62 |
60 |
58 |
53 |
52 |
51 |
37 |
| 2 |
61 |
57 |
54 |
51 |
58 |
54 |
51 |
48 |
46 |
44 |
32 |
| 3 |
57 |
51 |
47 |
43 |
53 |
48 |
45 |
43 |
40 |
38 |
29 |
| 4 |
52 |
46 |
41 |
38 |
49 |
43 |
39 |
39 |
36 |
33 |
25 |
| 5 |
48 |
41 |
36 |
33 |
45 |
39 |
35 |
35 |
32 |
29 |
22 |
| 6 |
45 |
37 |
32 |
29 |
42 |
36 |
31 |
32 |
28 |
26 |
20 |
| 7 |
42 |
34 |
29 |
26 |
39 |
32 |
28 |
29 |
26 |
23 |
18 |
| 8 |
39 |
31 |
26 |
23 |
36 |
30 |
25 |
27 |
23 |
21 |
16 |
| 9 |
36 |
28 |
24 |
20 |
34 |
27 |
23 |
25 |
21 |
19 |
15 |
| 10 |
34 |
26 |
22 |
19 |
32 |
25 |
21 |
23 |
19 |
17 |
13 |
SPECIFICATIONS
Housing:
6063 T5 extruded aluminum.
Optical system:
Optical system constructed of highly specular aluminum to
produce a direct/indirect distribution. Aluminum parabolic louver shall have 29 cells per
4ft to produce 55 degree cutoff along the lamp axis.
Row ends:
Mitered aluminum extrusion sculptured end caps.
Joints & Intersections:
All joints shall be accomplished using TwinLock
joining system. Optional intersections in "L", "T", or "X"
configurations, shall be mitered aluminum extrusion.
Mounting:
All mounts shall have tamper proof infinite vertical
adjustment capability. Mounts shall be independently certified up to Zone 4 seismic
requirements and able to accept loads up to 1000lb.
Electrical:
All luminaire sections shall be factory pre-wired to
section ends, utilizing segregated raceways. Optional quick connect plugs are available.
Ballast:
Electronic: rapid start or dimming.
Approvals:
Certified to UL & CSA standards.
Finish:
Thermosetting polyester, electrostatically applied meeting
AAMA 603.8. Available in Ledalite standard white and in a full architec-tural spectrum of
colors. Medium gloss finish as standard.

Based on a floor reflectance of 0.2
©1998 Ledalite Architectural Products Inc. 9087A - 198th
Street, Langley, B.C., Canada, V1M 3B1
Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA
(5332) Email: info@ledalite.com WWW:
http://www.ledalite.com
Note: Specifications subject to change without notice. |