Minuet Asymmetry

2 T8 - Direct / Indirect

PHOTOMETRY

OPTICAL SETTING A:

Lower wall brightness plus maximum uniformity on wall

Report# 2100607
Efficiency 68.7%
Peak Candela Value 1217 @ 142.5°
Peak Zenith Ratio 1.4:1
Asymmetric Effectiveness* 38.1%

CANDELA DISTRIBUTION

Vert. Angle

Horizontal   Angle

Zonal Lumens
0 45 90 135 180
0 286 286 286 286 286  
5 276 278 283 292 295 27
15 254 254 260 293 311 76
25 217 216 227 272 293 110
35 160 167 182 218 235 118
45 118 106 108 132 161 94
55 95 40 20 46 71 42
65 22 9 2 4 1 8
75 6 7 0 0 0 3
85 4 4 0 0 0 1
90 7 5 0 0 0  
95 144 141 30 5 0 90
105 557 537 158 310 274 377
115 990 815 310 412 501 565
125 1143 929 457 481 563 613
135 1197 1021 590 553 606 595
145 1217 1071 705 631 654 523
155 1187 1065 795 705 706 406
165 1094 1012 857 770 763 252
175 956 935 890 851 839 86
180 895 895 895 895 895  

COEFFICIENTS OF UTILIZATION (%)

Ceiling Wall RCR 80 70 50 0
70 50 30 10 70 50 30 50 30 10 0
0 67 67 67 67 59 59 59 42 42 42 8
1 61 59 56 54 53 51 49 37 36 35 7
2 56 51 48 44 49 45 42 33 31 29 6
3 51 45 41 37 44 40 36 29 27 25 6
4 47 40 35 31 41 35 31 26 23 21 5
5 43 36 30 27 37 31 27 23 20 18 4
6 39 32 27 23 34 28 24 21 18 16 4
7 36 29 24 20 32 25 21 19 16 14 3
8 34 26 21 17 29 23 19 17 14 12 3
9 31 23 19 15 27 21 17 15 13 11 3
10 29 21 17 14 25 19 15 14 11 9 3

Based on a floor reflectance of 0.2

OPTICAL SETTING B:

Higher wall brightness with maximum efficiency & more backlight

CANDELA  DISTRIBUTION

Vert.Angle Horizontal Angle ZonalLumens
0 45 90 135 180
0 270 270 270 270 270  
5 264 262 266 273 277 26
15 242 240 246 273 289 72
25 206 205 214 252 275 106
35 155 159 171 203 222 112
45 122 103 101 123 153 90
55 97 41 19 43 66 42
65 27 9 2 5 2 9
75 5 5 0 1 4 4
85 3 5 0 0 0 1
90 8 6 0 0 0  
95 113 121 40 5 0 88
105 533 524 207 318 283 393
115 983 857 404 498 573 628
125 1203 1009 595 627 698 719
135 1294 1145 772 753 802 724
145 1362 1242 921 876 900 657
155 1377 1270 1040 987 992 519
165 1316 1260 1122 1081 1070 331
175 1219 1207 1167 1138 1139 114
180 1171 1171 1171 1171 1171  

COEFFICIENTS OF UTILIZATION (%)

Ceiling Wall RCR 80 70 50 0
70 50 30 10 70 50 30 50 30 10 0
0 78 78 78 78 67 67 67 48 48 48 7
1 71 68 65 62 61 59 57 42 41 40 7
2 65 59 55 51 56 52 48 37 35 33 6
3 59 52 47 43 51 45 41 33 30 28 5
4 54 46 40 36 47 40 36 29 26 24 5
5 49 41 35 31 43 36 31 26 23 20 4
6 45 36 31 26 39 32 27 23 20 18 4
7 42 33 27 23 36 29 24 21 18 15 3
8 39 30 24 20 33 26 21 19 16 13 3
9 36 27 21 18 31 24 19 17 14 12 3
10 33 24 19 15 29 21 17 16 13 11 2

Based on a floor reflectance of 0.2

SPECIFICATIONS

Housing:

6063 T5 extruded aluminum.

Optical system:

Constructed of highly specular aluminum, and a highly reflective 24 ga. metal, to produce a semi-indirect distribution.

Row ends:

Mitered aluminum extrusion sculptured end caps.

Joints & Intersections:

All joints shall be accomplished using TwinLock ™ joining system. Optional intersections in "L", "T", or "X" configu-rations,

shall be mitered aluminum extrusion.

Mounting:

Brackets attach to existing structure anywhere behind fixture. Fully adjustable mounting brackets to provide up to 1/8"

wall variance and allow for vertical fixture leveling.

Electrical:

All luminaire sections shall be factory pre-wired to section ends. Optional quick connect plugs are available.

Ballast:

Electronic: rapid start.

Approvals:

Certified to UL & CSA standards.

Finish:

Thermosetting polyester, electrostatically applied meeting AAMA 603.8. Available in Ledalite standard white and in a full architectural spectrum of colors. Medium gloss finish as standard.

*Asymmetric efficiency refers to the percentage of lamp lumens distributed on the room side of the luminaire, above 90 degrees.


©1997 Ledalite Architectural Products Inc. 9087A - 198th Street, Langley, B.C., Canada, V1M 3B1

Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Email: info@ledalite.com  WWW: http://www.ledalite.com

Note: Specifications subject to change without notice.