DIMMABLE FLUORESCENT STRIPLIGHT

40w

Height (Top to bottom): 4- 5/8"
Width
(Side to side): 3- 3/4"
Length
(End to end): 48- 3/8"Gel

Gel(2): 4- 3/8" x 24"

#FLR-1

Weight 14 Ibs.

INCLUSIONS

  • Trunnion - Lamp Shield/Color Holder
  • Three Foot, 4-Wire Lead (UL)
  • Three Foot, 3-Wire Lead (non-UL)

ILLUMINATION FIELD

38° spread parallel to fixture = (throw x 0.69) + 4'

150° spread perpendicular to fixture = throw x 7.46

INTENSITY

Lamp Lumens (lamp) CBCP (in unit) °K CRI Hrs.
(All F40WT12/RS Class Lamps are Compatibfe -Those below are for fifustration Purposes).
F40SPX30T12RS* 3250 970 3000 82 20000
F40SPX35T12RS* 3250 970 3500 82 20000
F40SPX41T12RS* 3250 970 4100 82 20000
F40SPX50T12RS* 3100 930 5000 82 20000
F40BLB Blacklight Blue* - - - - 20000

* or equivalent lamp

To find light output in footcandles (fc) at any distance: CBCP / (throw distance)2 = fc

- For proper performance, compatible dimmer must be properly trimmed and maintained.

- Fixture performance may vary between dimmer types.

SPECIFICATIONS

The luminaire shall be a UL/C-UL Listed 40w fluorescent striplight with an integral 120V Class P dimming ballast (containing no PCB's). The housing shall be of extruded aluminum with an aluminum ballast plate and end caps. The housing shall be designed to provide an integral reflecting surface, optimizing light output, and shall accept snap-on clear extruded plastic lamp shields. The lamp shields shall also be designed to allow plastic color media to be secured in place conveniently. The unit shall be able to be supported using either standard triangular trunnion or L brackets. The electrical configuration shall allow the unit to be dimmed using most existing theatrical dimmers.

Relamping shall be accomplished by removing the lamp shields and snapping the lamp out of the lamp holders, no tools shall be required. Relamping shall not disturb the prefocused tamp/reflector alignment.

The luminaire shall be supplied with two 16 gauge steel single mount trunnion for overhead or floor use, two plastic lamp shields, and four wire leads (UL) or three wire leads (non-UL) encased in fiberglass sleeving.

The unit shall be supplied with an aluminum finish.

Copyright © 1996 Lighting & Electronics, Inc.



Request for Information / Request a Catalog from Lighting & Electronics Inc.
 
 
 
To request more information from Lighting & Electronics Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.