| SU/SO SERIES Surface Luminaires |

|
Catalog Number: SU24014-BE1FBRS .125
Pattern 12 acrylic lens.
Lamps: Two F40T12/CW Each Rated 3100
Lumens.
Total Luminaire Efficiency = 63.3%
Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.3
| Coefficients
of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 1 |
70 |
67 |
65 |
68 |
66 |
64 |
63 |
62 |
60 |
| 2 |
65 |
60 |
57 |
63 |
59 |
56 |
57 |
54 |
52 |
| 3 |
50 |
54 |
50 |
58 |
53 |
49 |
51 |
48 |
45 |
| 4 |
55 |
49 |
44 |
54 |
48 |
43 |
46 |
42 |
39 |
| 5 |
51 |
44 |
39 |
50 |
43 |
38 |
42 |
37 |
34 |
| 6 |
47 |
40 |
34 |
46 |
39 |
34 |
38 |
33 |
30 |
| 7 |
44 |
36 |
31 |
43 |
35 |
30 |
34 |
30 |
27 |
| 8 |
40 |
32 |
27 |
39 |
32 |
27 |
31 |
27 |
23 |
| 9 |
37 |
29 |
24 |
36 |
29 |
24 |
28 |
23 |
20 |
| 10 |
35 |
26 |
21 |
34 |
26 |
21 |
25 |
21 |
18 |

| Zonal
Lumen Summary |
| Zone |
Lumens |
%Lamp |
%Fixt |
| 0-30 |
1242 |
21.2 |
33.6 |
| 0-40 |
2004 |
34.3 |
54.1 |
| 0-60 |
3190 |
54.5 |
86.2 |
| 0-90 |
3702 |
63.3 |
100.0 |
Catalog Number: SU44024-BE1FBRS .125 Pattern
12 acrylic lens.
Lamps : Four F40T12/CW Each Rated 3100 Lumens.
Total Luminaire Efficiency = 71.4%
Plane : O-DEG 90-DEG
Spacing Criteria : 1.3 1.4
| Coefficients
of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 1 |
79 |
76 |
73 |
77 |
74 |
72 |
71 |
69 |
67 |
| 2 |
73 |
67 |
63 |
71 |
66 |
62 |
64 |
60 |
57 |
| 3 |
67 |
60 |
55 |
65 |
59 |
54 |
57 |
53 |
50 |
| 4 |
62 |
54 |
48 |
60 |
53 |
48 |
51 |
47 |
43 |
| 5 |
57 |
48 |
42 |
55 |
47 |
42 |
46 |
41 |
37 |
| 6 |
52 |
43 |
37 |
51 |
43 |
37 |
41 |
36 |
33 |
| 7 |
48 |
39 |
33 |
47 |
38 |
33 |
37 |
32 |
29 |
| 8 |
44 |
35 |
29 |
43 |
35 |
29 |
34 |
28 |
25 |
| 9 |
41 |
31 |
26 |
40 |
31 |
25 |
30 |
25 |
21 |
| 10 |
38 |
29 |
23 |
37 |
28 |
23 |
27 |
22 |
19 |

| Zonal
Lumen Summary |
| Zone |
Lumens |
%Lamp |
%Fixt |
| 0-30 |
2545 |
21.8 |
30.5 |
| 0-40 |
4216 |
36.0 |
50.4 |
| 0-60 |
7089 |
60.6 |
84.4 |
| 0-90 |
8357 |
71.4 |
100.0 |

* For 277 volt, substitute '4'
LAMPS:
| 20 - F20 |
| 17 - F017 |
| 40 - F40ES |
| 32 - FO32 |
| U6 - FB40ES U6" c/c |
| U6 - FB031 - T8 |
| U2 - FB031 U1-5/8" c/c |
| 4T - 40 Watt Twin Tube |
BALLASTS:
| BH - 430 ma Trigger Start 20 Watt |
| 270
ma 40 Watt Twin Tube |
| BE - 430 ma Rapid Start |
| Energy
Saving |
| ET - 430 ma Electronic |
| CT - 430 ma Electronic (3 lamp) |
| OT - 265 ma Magnetic Octron |
| EO - 265 ma Electronic Octron |
| CO - 265 ma Electronic Octron |
| (3 or
4 Lamp) |
Note: On 3 or 4 lamp
electronic fixtures, CO designates a single 3 or 4 lamp ballast in
fixture. CT designates one 3 lamp ballast. ET and EO designate 2 ballasts in
fixture, with inboard lamp(s) wired separately.
LENSES/LOUVERS:
FA Pattern 12 Clear Acrylic .095" Lens
is standard.
For optional lenses or louvers, see
ACCESSORIES section of catalog.
DOOR FRAMES:
RS Full White Flush Steel Door
is standard.
For optional steel or aluminum door frames,
see ACCESSORIES section of catalog.
OPTIONS:
For side diffusers, change Series
designator from SU to SO.
(Not available for 1 x 2)
Use the following suffix for:
-F1 Fusing, one per fixture
-F2 Fusing, one per ballast
-RF1 Ratio Interference Filter, one
per fixture
-RF2 Radio Interference Filter, one
per ballast
-TP Tamper Resistant Door Frame
(steel doors only) with spanner - head captive screws, 2 per side
-4S Stem Mounting for 2 x 2, 2 x 4, 4 x 4
Emergency Ballast - Please consult options
page for complete listings.
Dimming Ballast - Please Consult the
Factory.
Knockouts for Continuous Row Mounting -
Available special order, consult factory.



specifications and dimensional data subject
to change without notice
No. shown indicates mounting/knockout
diagrams. See Options & Accessories section of catalog.
LUMAX INDUSTRIES, INC.
SU/SO. 697 |