  Lumax Industries Inc.   Recessed Parabolic  

Recessed Parabolic - Page 3

   

Recessed Parabolic

EPG SERIES

EurolOuver Luminaire

 

PHOTOMETRIC DATA

Catalog Number: EPG2U622-EO1L24

24 Cell 1" Deep Semi-Specular Faceted Aluminum Louver.

Lamps: Two FB32T8/TL735/6 Each Rated at 250 Lumens.

Total Luminaire Efficiency = 43.5%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.1 0.8
Shielding Angles : 17 40

Zonal Lumen Summary
Zone Lumens %Lamp %Fixt
0-30 1224 22.3 51.2
0-40 1740 31.6 72.7
0-60 2276 41.4 95.1
0-90 2394 43.5 100.0
90-180 0 0.0 0.0
0-180 2394 43.5 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20%
RC 80% 70% 50%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10%
0 52 52 52 52 51 51 51 51 48 48 48
1 49 48 46 45 48 47 46 45 45 44 43
2 46 44 42 40 45 43 41 40 42 40 39
3 43 40 38 36 42 40 37 35 38 36 35
4 41 37 34 32 40 36 34 32 35 33 31
5 38 34 31 29 37 33 31 29 33 30 28
6 36 31 28 26 35 31 28 26 30 28 26
7 34 29 26 24 33 29 26 24 28 25 24
8 31 27 24 21 31 26 23 21 26 23 21
9 29 24 21 19 29 24 21 19 24 21 19
10 27 22 20 18 27 22 19 18 22 19 17

 

Visual Comfort Probability Table Average 100FC, Reflectances 80/50/20
Room Size 0° Plane Ceiling Ht. 90° Plane Ceiling Ht.
W L 8.5 10.0 8.5 10.0
20 20 77 77 99 99
30 30 78 76 99 99
30 60 76 74 99 99
60 30 80 77 99 99
60 60 78 77 99 99

 

Average Luminance (Footlamberts)
Angle in Deg Average 0-Deg Average 45-Deg Average 90-Deg
45 4970. 1759. 552.
55 4081. 600. 25.
65 2977. 216. 0.
75 1602. 109. 0.
85 766. 0. 0.

 

ORDERING GUIDE

EXAMPLE: EPG41722-EO1S24 (Static)
Select designators from chart to construct catalog number.
Example shown is for a static fixture. No air handling designators are used.
For an air model, use appropriate designators. Examples:
EPGT41722-EO1S24 (Top slots)
 

LAMPS:

17 - FO17
U6 - FB31T8
32 - F032
40 - F40ES
 

BALLASTS:

BE  - 430 ma Rapid Start Energy Saving
ET - 430 ma Electronic
CT - 430 ma Electronic (3 lamp)
OT - 265 ma Magnetic Octron
EO - 265 ma Electronic Octron
CO - 265 ma Electronic Octron (3 or 4 Lamp)

Note : On 3 or 4 lamp electronic fixtures, CO designates a single 3 or 4 lamp ballast in fixture; CT designates one 3 lamp ballast. ET and EO designate 2 ballasts in fixture, with inboard lamp(s) wired separately.

LOUVER FINISHES:
** Specular Low Iridescent Silver Louver (S) is standard.
Use the following designator for Optional Louver:
L-Semi-Specular Low Iridescent
Different louver cell options available as special order.
 

OPTIONS:

Use the following suffix:
-F1 Fusing, one per fixture
-F2 Fusing, one per ballast
-RF1 Radio interference Filter, one per fixture
-RF2 Radio Interference Filter, one per ballast
-FX1 Flex - 3/8 x 6 ft., 18/3 with two straight connectors
Emergency Ballast - Please consult options page for complete listing.
Dimming Ballasts - Please Consult the Factory.

 

DIMENSIONS

specifications and dimensional data subject to change without notice

Lumax Industries, Inc.

EPG1197



Request for Information / Request a Catalog from Lumax Industries Inc.
 
 
 
To request more information from Lumax Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.