| PG SERIES 1 x 4 Parabolic Luminaires |

|
Catalog Number: PG24014-BE1S06
6 Cell 3" Deep Semi-Specular Aluminum Louver:
Lamps: Two F40T12/CW Each Rated 3100 Lumens.
Total Luminaire Efficiency = 72.9%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.5 |
| Shielding Angles : |
24 |
24 |

0-DEG - 90-DEG -
TEST NUMBER: 05423
Zonal Lumen Summary |
| Zone |
Lumens |
%Lamp |
%Fixt |
| 0-30 |
1353 |
21.8 |
29.9 |
| 0-40 |
2294 |
37.0 |
50.7 |
| 0-60 |
4139 |
66.8 |
91.5 |
| 0-90 |
4521 |
72.9 |
100.0 |
| Coefficients
of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
87 |
87 |
87 |
85 |
85 |
85 |
81 |
81 |
81 |
| 1 |
81 |
78 |
76 |
79 |
77 |
75 |
74 |
72 |
70 |
| 2 |
75 |
71 |
67 |
74 |
69 |
66 |
67 |
64 |
61 |
| 3 |
70 |
63 |
58 |
68 |
62 |
58 |
60 |
56 |
53 |
| 4 |
64 |
57 |
51 |
63 |
56 |
51 |
54 |
50 |
46 |
| 5 |
59 |
50 |
45 |
57 |
50 |
44 |
48 |
43 |
40 |
| 6 |
54 |
45 |
39 |
53 |
44 |
39 |
43 |
38 |
34 |
| 7 |
50 |
40 |
34 |
48 |
40 |
34 |
39 |
34 |
30 |
| 8 |
46 |
36 |
30 |
44 |
36 |
30 |
35 |
29 |
26 |
| 9 |
42 |
32 |
26 |
41 |
32 |
26 |
31 |
26 |
22 |
| 10 |
39 |
29 |
23 |
38 |
29 |
23 |
28 |
23 |
19 |
| Visual Comfort Probability Table Average 100 FC, Reflectances
80/50/20 |
| Room Size |
0° Plane Ceiling Ht. |
90° Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
64 |
56 |
66 |
57 |
| 30 |
30 |
75 |
66 |
76 |
66 |
| 30 |
60 |
79 |
72 |
80 |
73 |
| 60 |
30 |
75 |
70 |
77 |
70 |
| 60 |
60 |
79 |
76 |
80 |
77 |
| Average
Luminance (Footlamberts) |
| Vertical
Angle |
Horizontal
Plane |
| |
0° |
90° |
| 45 |
1599. |
2122. |
| 55 |
1440. |
2095. |
| 65 |
908. |
593. |
| 75 |
67. |
67. |
| 85 |
25. |
25. |
| EXAMPLE: |
| PG23214-EO1L06 (Static) |
| Select designators from chart to construct catalog number. |
| Example shown is for a staitc fixture. No air
handling designators are used. |
| For an air model, use appropriate designators. |
| Examples: |
| PGT23214-EO1L06 |
| (Air model with top slots) |
| PGS23214-EO1L06 |
| (Air model with side slots) |
| PGC23214-EO1L06 |
| (Air model with top and side slots) |
| For control vanes, add 'V' after slot designator: |
| PGTV23214-EO1L06 |
| (PGCV fixtures furnished with side vanes only) |
| LAMPS: |
| 40 - F40ES |
| 32 - F032 |
| BALLASTS: |
| BE - 430 ma Rapid Start Energy Saving |
| ET - 430 ma Electronic |
| CT - 430 ma Electronic (3 lamp) |
| OT - 265 ma Magnetic Octron |
| EO - 265 ma Electronic Octron |
| CO - 265 ma Electronic Octron (3 or 4 Lamp) |
Note: On 3 or 4 lamp electronic fixtures, CO designates a single
3 or 4 lamp ballast in fixture. CT designates one 3 lamp ballast. ET and EO
designate 2 ballasts in fixture, with inboard lamp(s) wired separately.
| LOUVER FINISHES: |
| **Semi-Specular Low Iridescent Silver Louver (L) is
standard. |
| For Optional Louver Finishes, use the following
designators: |
| N - Non Iridescent Economy Louver |
| W - White Painted |
| C - Champagne Gold |
| OPTIONS: |
| Use the following suffix for: |
| -F1 Fusing, one per fixture |
| -F2 Fusing, one per ballast |
| -RF1 Radio interference Filter, one per fixture |
| -RF2 Radio Interference Filter, one per ballast |
| -FX1 Flex - 3/8 x 6 ft., 18/3 with two straight connectors |
| Emergency Ballast - Please consult options page for
complete listings. |
| Dimming Ballasts - Please Consult the Factory. |
Lumax Industries, Inc.
PG.1x4.697 |