| PG SERIES 2
x 2 Parabolic Luminaires |

|
DATA
Catalog Number: PG2U622-BE1S09
9 Cell 3" Deep Semi-Specular Aluminum Louver.
Lamps: Two F40T12/U6/CW Each Rated at 2935 Lumens.
Total Luminaire Efficiency = 65.3%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.3 |
| Shielding Angles : |
24 |
24 |
| Zonal
Lumen Summary |
| Zone |
Lumens |
%Lamp |
%Fixt |
| 0-30 |
1195 |
20.4 |
31.2 |
| 0-40 |
1957 |
33.3 |
51.0 |
| 0-60 |
3520 |
60.0 |
91.8 |
| 0-90 |
3835 |
65.3 |
100.0 |
| Coefficients
of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
78 |
78 |
78 |
76 |
76 |
76 |
73 |
73 |
73 |
| 1 |
73 |
70 |
68 |
71 |
69 |
67 |
66 |
65 |
63 |
| 2 |
68 |
63 |
60 |
66 |
62 |
59 |
60 |
57 |
55 |
| 3 |
63 |
57 |
53 |
61 |
56 |
52 |
54 |
51 |
48 |
| 4 |
58 |
51 |
46 |
56 |
50 |
45 |
49 |
45 |
41 |
| 5 |
53 |
45 |
40 |
52 |
45 |
40 |
43 |
39 |
36 |
| 6 |
49 |
41 |
35 |
47 |
40 |
35 |
39 |
34 |
31 |
| 7 |
45 |
36 |
31 |
44 |
36 |
31 |
35 |
30 |
27 |
| 8 |
41 |
33 |
27 |
40 |
32 |
27 |
31 |
27 |
23 |
| 9 |
38 |
29 |
24 |
37 |
29 |
24 |
28 |
23 |
20 |
| 10 |
35 |
26 |
21 |
34 |
26 |
21 |
25 |
21 |
18 |

| Visual Comfort Probability Table Average 100FC, Reflectances
80/50/20 |
| Room Size |
0° Plane Ceiling Ht. |
90° Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
71 |
63 |
71 |
62 |
| 30 |
30 |
80 |
73 |
80 |
72 |
| 30 |
60 |
83 |
76 |
81 |
75 |
| 60 |
30 |
80 |
75 |
80 |
75 |
| 60 |
60 |
83 |
78 |
81 |
77 |
| Average
Luminance (Footlamberts) |
| Vertical
Angle |
Horizontal
Plane |
|
0° |
90° |
| 45 |
1315. |
1668. |
| 55 |
1189. |
1935. |
| 65 |
754. |
415. |
| 75 |
62. |
66. |
| 85 |
11. |
11. |
Catalog Number: PG3U222-OT1L09
9 Cell 3" Deep Low Iridescent Semi-Specular Louver.
Lamps: Three FB031/35K Octron
Curvalume Each Rated 2800 Lumens.
Total Luminaire Efficiency = 66.8%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.4 |
| Shielding Angles : |
24 |
37 |
Zonal Lumen Summary |
| Zone |
Lumens |
%Lamp |
%Fixt |
| 0-30 |
1975 |
23.5 |
35.2 |
| 0-40 |
3256 |
38.9 |
58.2 |
| 0-60 |
5342 |
63.6 |
95.2 |
| 0-90 |
5613 |
66.8 |
100.0 |
| Coefficients
of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
80 |
80 |
80 |
78 |
78 |
78 |
74 |
74 |
74 |
| 1 |
75 |
72 |
70 |
73 |
71 |
69 |
68 |
67 |
65 |
| 2 |
70 |
66 |
62 |
68 |
65 |
61 |
62 |
60 |
58 |
| 3 |
65 |
60 |
55 |
64 |
59 |
55 |
57 |
53 |
51 |
| 4 |
60 |
54 |
49 |
59 |
53 |
49 |
51 |
48 |
45 |
| 5 |
56 |
48 |
43 |
54 |
48 |
43 |
46 |
42 |
39 |
| 6 |
52 |
44 |
39 |
50 |
43 |
38 |
42 |
38 |
34 |
| 7 |
48 |
39 |
34 |
47 |
39 |
34 |
38 |
34 |
30 |
| 8 |
44 |
35 |
30 |
43 |
35 |
30 |
34 |
30 |
26 |
| 9 |
40 |
32 |
27 |
39 |
31 |
26 |
31 |
26 |
23 |
| 10 |
37 |
29 |
24 |
36 |
28 |
24 |
28 |
23 |
20 |
TEST NUMBER: 05408
| Visual Comfort Probability Table Average 100FC, Reflectances
80/50/20 |
| Room
Size |
0°
Plane Ceiling Ht. |
90°
Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
69 |
61 |
79 |
72 |
| 30 |
30 |
78 |
70 |
84 |
78 |
| 30 |
60 |
81 |
75 |
87 |
82 |
| 60 |
30 |
80 |
74 |
87 |
82 |
| 60 |
60 |
84 |
79 |
89 |
85 |
| Average
Luminance (Footlamberts) |
| Vertical
Angle |
Horizontal
Plane |
| |
0° |
90° |
| 45 |
2086. |
2537. |
| 55 |
1810. |
1032. |
| 65 |
903. |
244. |
| 75 |
108. |
85. |
| 85 |
57. |
34. |
Catalog Number: PG34T22-BH1L09
9 Cell 3" Deep Low Iridescent Semi-Specular Louver.
Lamps: Three BIAX F40BX/RS/SPX35 Each Rated 3150 Lumens.
Total Luminaire Efficiency = 70.5%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.9 |
| Shielding Angles : |
23 |
38 |
| Zonal
Lumen Summary |
| Zone |
Lumens |
%Lamp |
%Fixt |
| 0-30 |
1889 |
20.0 |
28.3 |
| 0-40 |
3345 |
35.4 |
50.2 |
| 0-60 |
6237 |
66.0 |
93.6 |
| 0-90 |
6664 |
70.5 |
100.0 |
| Coefficients
of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
84 |
84 |
84 |
82 |
82 |
82 |
78 |
78 |
78 |
| 1 |
79 |
76 |
74 |
77 |
74 |
72 |
72 |
70 |
68 |
| 2 |
73 |
69 |
65 |
71 |
67 |
64 |
65 |
62 |
59 |
| 3 |
68 |
62 |
57 |
66 |
61 |
56 |
59 |
55 |
52 |
| 4 |
62 |
55 |
50 |
61 |
54 |
49 |
53 |
48 |
45 |
| 5 |
57 |
49 |
43 |
56 |
48 |
43 |
47 |
42 |
39 |
| 6 |
53 |
44 |
38 |
51 |
43 |
38 |
42 |
37 |
34 |
| 7 |
48 |
39 |
33 |
47 |
39 |
33 |
38 |
33 |
29 |
| 8 |
44 |
35 |
29 |
43 |
34 |
29 |
33 |
28 |
25 |
| 9 |
40 |
31 |
25 |
39 |
30 |
25 |
30 |
25 |
21 |
| 10 |
37 |
28 |
22 |
36 |
27 |
22 |
27 |
22 |
18 |
TEST NUMBER: 05493
| Visual Comfort Probability Table Average 100FC, Reflectances
80/50/20 |
| Room
Size |
0°
Plane Ceiling Ht. |
90°
Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
60 |
52 |
66 |
56 |
| 30 |
30 |
70 |
62 |
74 |
65 |
| 30 |
60 |
75 |
68 |
79 |
71 |
| 60 |
30 |
74 |
68 |
78 |
72 |
| 60 |
60 |
79 |
73 |
82 |
76 |
| Average
Luminance (Footlamberts) |
| Vertical
Angle |
Horizontal
Plane |
| |
0° |
90° |
| 45 |
2027. |
3753. |
| 55 |
1794. |
2094. |
| 65 |
1045. |
458. |
| 75 |
132. |
101. |
| 85 |
57. |
34. |
Lumax Industries, Inc.
PG.697 |