PG SERIES

2 x 4 Parabolic Luminaires

 

PHOTOMETRIC DATA

Catalog Number: PG33224-EO1L18

18 Cell 3" Deep Semi-Specular Aluminum Louver:

Lamps: Three F3218/41K Rated 2900 Lumens.

Total Luminaire Efficiency = 70.8%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.6
Shielding Angles : 30  42

 

Zonal Lumen Summary
Zone Lumens %Lamp %Fixt
0-30 2050 23.6 33.3
0-40 3519 40.4 57.2
0-60 5868 67.5 95.3
0-90 6157 70.8 100.0
0-180 0 0.0 0.0
90-180 6157 70.8 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20
RC 80% 70% 50%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10%
0 84 84 84 84 82 82 82 82 79 79 79
1 79 77 74 72 77 75 73 71 72 71 69
2 74 70 66 63 72 68 65 62 66 63 61
3 69 63 58 55 67 62 58 54 60 56 53
4 64 57 52 48 62 56 51 48 54 50 47
5 59 51 46 42 57 50 45 41 49 44 41
6 54 46 41 37 53 45 40 36 44 40 36
7 50 41 36 32 49 41 36 32 40 35 32
8 46 37 32 28 45 37 31 28 36 31 27
9 42 33 28 24 41 33 27 24 32 27 24
10 39 30 25 21 38 30 24 21 29 24 21

Visual Comfort Probability Table Average 100 FC, Reflectances 80/50/20
Room Size 0° Plane Ceiling Ht. 90° Plane Ceiling Ht.
W L 8.5 10.0 13.0 16.0
20 20 85 80 81 79
30 30 89 84 79 74
30 60 91 87 83 78
60 30 90 87 83 78
60 60 92 89 85 81

 

Luminance in Candela Per Square Meter
Angle in Deg Average 0° Average 90°
0 4067. 4067.
45 3483. 4714.
55 2796. 2071.
65 542. 873.
75 206. 218.
85 92. 111.

Catalog Number: PG44024-BE1S32

32 Cell" Deep Semi-Specular Aluminum Louver:

Lamps: Four F40T12/CW Rated 3100 Lumens.

Total Luminaire Efficiency = 64.8%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.4
Shielding Angles : 28  46

 

Zonal Lumen Summary
Zone Lumens %Lamp %Fixt
0-30 2870 23.1 35.7
0-40 4763 38.4 59.2
0-60 7750 62.5 96.4
0-90 8041 64.8 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20
RC 80% 70% 50%
RW 70% 50% 30% 70% 50% 30% 50% 30% 10%
0 77 77 77 75 75 75 72 72 72
1 73 70 68 71 69 67 66 65 63
2 68 64 61 66 63 60 61 58 56
3 63 58 54 62 57 53 55 52 49
4 59 52 48 57 52 47 50 46 44
5 54 47 42 53 47 42 45 41 38
6 50 43 38 49 42 37 41 37 34
7 46 39 33 45 38 33 37 33 30
8 43 35 30 42 34 29 33 29 26
9 39 31 26 38 31 26 30 25 22
10 36 28 23 36 28 23 27 23 20

para13c.gif (7652 bytes)

0 DEG -90 DEG-

TEST NUMBER 05419

Visual Comfort Probability Table Average 100 FC, Reflectances 80/50/20
Room Size 0° Plane Ceiling Ht. 90° Plane Ceiling Ht.
W L 8.5 10.0 8.5 10.0
20 20 82 73 89 78
30 30 88 81 92 85
30 60 89 83 92 86
60 30 88 81 92 85
60 60 88 83 92 86

 

Average Luminance (Footlamberts)
Vertical Angle 90°
45 1420. 1383.
55 1211. 1216.
65 358. 104.
75 51. 36.
85 16. 16.

 

ORDERING GUIDE

 

 

EXAMPLE:
PG33224-EO1L18 (Static)
Select designators from chart to construct catalog number.
Example shown is for a static fixture. No air handling designators are used.
For an air model, use appropriate designators.
Examples:
PGT33224-EO1L18 (Top slots)
PGS33224-EO1L18 (Side slots)
PGC33224-EO1L18 (Top and side slots)
For control vanes, add 'V':
PGTV33224-BE1L18
(PGCV fixtures furnished with side vanes only)
 

LAMPS:

40 - F40ES
32 - F032
 

BALLASTS:

BE - 430 ma Rapid Start Energy Saving
ET - 430 ma Electronic
CT - 430 ma Electronic (3lamp)
OT - 265 ma Magnetic Octron
EO - 265 ma Electronic Octron
CO - 265 ma Electronic Octron (3 or 4 Lamp)
Note: On 3 or 4 lamp electronic fixtures, CO designates a single 3 or 4 lamp ballast in fixture. CT designates one 3 lamp ballast. ET and EO designate 2 ballasts in fixture, with inboard lamp(s) wired separately.
 

LOUVER FINISHES:

**Semi-Specular Low Iridescent Silver Louver (L) is standard.
For Optional Louver Finishes, use the following designators:
N - Non Iridescent Economy Louver
W - White Painted
C - Champagne Gold
 

OPTIONS:

Use the following suffix for:
-F1 Fusing, one per fixture
-F2 Fusing, one per ballast
-RF1 Radio interference Filter, one per fixture
-RF2 Radio Interference Filter, one per ballast
-FX1 Flex - 3/8 x 6 ft., 18/3 with two straight connectors
Emergency Ballast - Please consult options page for complete listings.
Dimming Ballasts - Please Consult the Factory.
DIMENSIONS

specifications and dimensional data subject to change without notice.

Ceiling Opening for Flanged Models: 24-1/8" x 48-1/8"

Lumax Industries, Inc.

PG.2x4.697

Request for Information / Request a Catalog from Lumax Industries Inc.
 
 
 
To request more information from Lumax Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com