   Lumax Industries Inc.  Recessed Parabolic  

Recessed Parabolic - Page 15

 

 

5 PG SERIES / VDT

Parabolic Luminaires

 

PHOTOMETRIC DATA

Catalog Number: 5PG33224-EO1S27

27 Cell 4.25" Deep Specular Louver:

Lamps: Three F32T8/TL741 Rated at 2900 Lumens.

Total Luminaire Efficiency = 65.1%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.5
Shielding Angles : 34  45

 

Zonal Lumen Summary
Zone Lumens %Lamp %Fixt
0-30 2498 28.7 44.1
0-40 4241 48.8 74.9
0-60 5646 64.9 99.7
0-90 5662 65.1 100.0
90-180 0 0.0 0.0
0-180 5662 65.1 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20%
RC 80% 70% 50%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10%
0 77 77 77 77 76 76 76 76 72 72 72
1 73 71 70 68 72 70 68 67 67 66 65
2 69 66 63 61 68 65 62 60 63 60 59
3 65 61 57 54 64 60 56 54 58 55 53
4 61 56 52 48 60 55 51 48 53 50 48
5 57 51 47 43 56 50 46 43 49 45 43
6 54 47 42 39 53 46 42 39 45 42 39
7 50 43 38 35 49 42 38 35 41 38 35
8 46 39 34 31 45 38 34 31 38 34 31
9 43 35 30 27 42 35 30 27 34 30 27
10 40 32 27 24 39 32 27 24 31 27 24

Visual Comfort Probability Table Average 100 FC, Reflectances 80/50/20
Room Size 0° Plane Ceiling Ht. 90° Plane Ceiling Ht.
W L 8.5 10.0 8.5 10.0
20 20 95 94 98 97
30 30 95 92 98 97
30 60 95 92 98 98
60 30 95 92 98 98
60 60 92 93 98 98

 

Average Luminance (Footlamberts)
Angle in Deg Average 0-Deg Average 45-Deg Average 90-Deg
45 3386. 4392. 2106.
55 568. 661. 198.
65 50. 42. 38.
75 25. 19. 25.
85 0. 0. 19.

Catalog Number: 5PG3U222-EO1S12

12 Cell 4.25" Deep Specular Louver:

Lamps: Three  FB031/30K Each Rated 2800 Lumens.

Total Luminaire Efficiency = 57.2%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.3
Shielding Angles : 36 42

 

Zonal Lumen Summary
Zone Lumens %Lamp %Fixt
0-30 2216 26.4 46.1
0-40 3550 42.3 73.9
0-60 4790 57.0 99.7
0-90 4805 57.2 100.0
90-180 0 0.0 0.0
0-180 4805 57.2 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20%
RC 80% 70% 50%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10%
0 68 68 68 68 66 66 66 66 64 64 64
1 65 63 61 60 63 62 60 59 59 58 57
2 61 58 55 53 60 57 55 53 55 53 52
3 57 53 50 48 56 53 50 47 51 49 46
4 54 49 45 43 53 48 45 42 47 44 42
5 50 45 41 38 49 44 41 38 43 40 38
6 47 41 37 35 46 41 37 35 40 37 34
7 44 38 34 31 43 37 34 31 37 33 31
8 41 34 30 28 40 34 30 28 33 30 27
9 38 31 27 24 37 31 27 24 30 27 24
10 35 28 24 22 34 28 24 22 28 24 22

Visual Comfort Probability Table Average 100 FC, Reflectances 80/50/20
Room Size 0° Plane Ceiling Ht. 90° Plane Ceiling Ht.
W L 8.5 10.0 8.5 10.0
20 20 89 90 96 94
30 30 90 89 97 93
30 60 90 89 97 93
60 30 90 89 97 93
60 60 90 89 97 93

 

Average Luminance (Footlamberts)
Angle in Deg Average 0-Deg Average 45-Deg Average 90-Deg
45 6441. 7130. 4805.
55 1454. 1801. 395.
65 97. 89. 81.
75 27. 40. 53.
85 0. 0. 0.

 

ORDERING GUIDE

EXAMPLE:
5PG33224-EO1S27 (Static)
Select designators from chart to construct catalog number.
Example shown is for a staitc fixture. No air handling designators are used.
For an air model, use appropriate designators.
 

Examples:

5PGT33224-EO1S27 (Air model with top slots)
5PGS33224-EO1S27 (Air model with side slots)
5PGC33224-EO1S27 (Air model with top and side slots)
For control vanes, add 'V' after slot designator:
5PGTV33224-EO1S27
(PGCV fixtures furnished with side vanes only)
 

LAMPS:

40 - F40ES
32 - F032
17 - FO17
U2 - FB031 U1-5/8" c/c
4T - 40 Watt Twin Tube
 

BALLASTS:

BH - 270 ma 40 Watt Twin Tube Magnetic
BE - 430 ma Rapid Start Energy Saving Magnetic
ET - 430 ma Electronic
CT - 430 ma Electronic (3lamp)
OT - 265 ma Magnetic Octron
EO - 265 ma Electronic Octron or Twin Tube
CO - 265 ma Electronic Octron or Twin Tube (3 Lamp)
Note: On 3 electronic fixtures, CT and CO designate a single 3 ballast in fixture. ET and EO designate 2 ballasts in fixture, with inboard lamp(s) wired separately.
 

LOUVER FINISHES:

S - Low Iridescent Specular
 

OPTIONS:

Use the following suffix:
-F1 Fusing, one per fixture
-F2 Fusing, one per ballast
-RF1 Radio interference Filter, one per fixture
-RF2 Radio Interference Filter, one per ballast
-FX1 Flex - 3/8 x 6 ft., 18/3 with two straight connectors
Emergency Ballast - Please consult options page for complete listings.
Dimming Ballasts - Please Consult the Factory.
DIMENSIONS

specifications and dimensional data subject to change without notice.

Lumax Industries, Inc.

5PG997

Request for Information / Request a Catalog from Lumax Industries Inc.
 
 
 
To request more information from Lumax Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com