   Lumax Industries Inc.  Recessed Tropper  

Recessed Tropper - Page 13

 

 

RG SERIES

High Performance 1x4 Troffers


PHOTOMETRIC DATA

Catalog Number : RG24014-BE1FARS

.095 Pattern 12 acrylic lens.

Lamps: Two F40T12/CW Each Rated at 3100 Lumens.

Total Luminaire Efficiency = 68.5%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.3
Shielding Angles: 90 90

 

Zonal Lumen Summary
ZONE LUMENS %LAMP %FIXT
0 - 30 1492 24.1 34.9
0 - 40 2392 38.6 56.0
0 - 50 3720 60.0 87.1
0 - 90 4270 68.9 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20%

RC 80% 70% 50%
RW 70 50 30 70 50 30 50 30 10
0 82 82 82 80 80 80 77 77 77
1 76 74 71 74 72 70 69 67 65
2 70 66 62 69 62 61 62 59 57
3 65 59 55 64 58 54 56 53 49
4 61 53 48 59 53 48 51 47 43
5 56 48 43 55 47 42 46 41 36
6 52 44 38 51 43 38 42 37 34
7 48 39 34 47 39 34 38 33 30
8 44 36 30 43 35 30 34 29 26
9 41 32 27 40 32 26 31 26 23
10 38 29 24 37 29 24 28 24 20

 

Visual Comfort Probability Table Average 100 FC, Reflectance 80/50/20

Room Size

0° Plane Ceiling Ht.

90° Plane Ceiling Ht.

W L 8.5 10.0 8.5 10.0
20 20 60 64 61 65
30 30 53 57 54 57
30 60 44 47 45 48
60 30 56 59 56 60
60 60 46 48 47 49

 

Average Luminance (Footlamberts)
Vertical Angle Horizontal Plane
  90°
45 1496. 1425.
55 1099. 1021.
65 818. 779.
75 879. 835.
85 819. 748.

Catalog Number : RG23214-EO1FARS

.095 Pattern 12 acrylic lens.

Lamps: Two F32T8-SP41 Rated 2900 Lumens.

Total Luminaire Efficiency = 68.5%

Plane : O-DEG 90-DEG
Spacing Criteria : 1.2 1.3
Shielding Angles: 90 90

 

Zonal Lumen Summary
ZONE LUMENS %LAMP %FIXT
0 - 30 1369 23.6 34.5
0 - 40 2195 37.8 55.3
0 - 50 3427 59.1 86.3
0 - 90 3973 68.5 100.0

 

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20

RC 80% 70% 50%
RW 70 50 30 10 70 50 30 10 50 30 10
0 82 82 82 82 80 80 80 80 76 76 76
1 76 73 70 68 74 71 69 67 69 67 65
2 70 65 61 58 68 64 60 57 62 59 56
3 65 59 54 50 63 58 53 50 56 52 49
4 60 53 48 44 59 52 47 43 50 46 43
5 55 47 42 38 54 47 42 38 45 41 37
6 51 43 37 33 50 42 37 33 41 37 33
7 48 39 33 29 46 38 33 29 37 33 29
8 44 35 30 26 43 35 29 26 34 29 26
9 40 32 26 23 40 31 26 23 30 26 22
10 38 29 24 20 37 28 23 20 28 23 20

 

Visual Comfort Probability Table Average 100 FC, Reflectance 80/50/20
Room Size 0° Plane Ceiling Ht. 90° Plane Ceiling Ht.
W L 8.5 10.0 13.0 16.0
20 20 60 65 79 78
30 30 53 57 62 67
30 60 43 46 49 53
60 30 55 59 63 67
60 60 45 48 49 52

 

Luminance in Candela Per Square Meter

Angle in Deg Average 0-Deg Average 45-Deg Average 90-Deg
0 6083. 6083. 6083.
45 4649. 4709. 4590.
55 3472. 4554. 3283.
65 2612. 2315. 2513.
75 2659. 2052. 2497.
85 2926. 2245. 2766.

ORDERING GUIDE

trof13e.jpg (17591 bytes)

EXAMPLE : RG23214-EO1FARS (Static)

Select designators from chart to construct catalog number. Example shown is for a static fixture. No air handling designators are used.

For an air model, use appropriate designators.

Examples:

RG23214-EO1FARS (Static)

RGT23214-EO1FARA (Top slots)

RGS23214-E01FABS (Side slots)

RGC23214-EO1FABS (Top and side)

For control vanes, add 'V'

RGTV23214-E01FARA

(RGCV units furnished with side vanes only)

LAMPS:

40 - F40ES 32 - F032

BALLASTS:

BE - 430 ma Rapid Start Energy Saving

ET - 430 ma Electronic

CT - 430 ma Electronic (3 lamp)

OT - 265 ma Magnetic Octron

EO - 265 ma Electronic Octron

CO - 265 ma Electronic Octron (3 lamp)

Note: On 3 lamp electronic fixtures, CO designates a single 3 lamp ballast in fixture. CT designates one 3 lamp ballast. ET and EO designate 2 ballasts in fixture, with inboard lamp(s) wired separately.

LENSES/LOUVERS:

FA - Pattern 12 Clear Acrylic .095" Lens

FB - Pattern 12 Clear Acrylic. 125" Lens

HA - Holophane 8224 Lens

SP - 1/2" Sq. Molded Silver Parabolic Louver

Refer to RG 2x2 page or Lens/Louver Options page for complete listing.

DOOR FRAMES:

RS - Full White Steel Door, Flush

RA - Heat Removal White Steel Door, Flush

BS - Floating White Steel Door, Flush

RH - Full White Aluminum Door, Regressed

Refer to RG 2x2 page or Door Frame Selection Guide for complete listing.

OPTIONS:

Use the following suffix for:

-F1 Fusing, one per fixture

-F2 Fusing, one per ballast

-RF1 Radio Interference Filter, one per fixture

-RF2 Radio Interference Filter, one per ballast

-FX1 Flex - 3/8 x 6 ft., 18/3 with two straight connectors

Emergency Ballast - Please consult options page for complete listings.

Dimming Ballast - Please Consult the Factory.

For fixtures with lamps installed consult options page.

Ceiling opening for flanged models:

12-1/8" x 48-1/8."


DIMENSIONS

 

specifications and dimensional data subject to change without notice

LUMAX INDUSTRIES, INC.

RG.697

Request for Information / Request a Catalog from Lumax Industries Inc.
 
 
 
To request more information from Lumax Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com