| RG SERIES High Performance 2x2 Troffers |

|
Catalog Number : RG2U622-BE1FARS
.095 Pattern 12 acrylic lens.
Lamps: Two F40T12/U6/CW Each Rated at 2935 Lumens.

Total Luminaire Efficiency = 61.6%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.3 |
| Shielding Angles: |
90 |
90 |
| Zonal
Lumen Summary |
| ZONE |
LUMENS |
%LAMP |
%FIXT |
| 0 - 30 |
1213 |
20.7 |
33.5 |
| 0 - 40 |
1953 |
33.3 |
54.0 |
| 0 - 50 |
3129 |
53.3 |
86.5 |
| 0 - 90 |
3619 |
61.6 |
100.0 |
Coefficients of Utilization - Zonal Cavity Method Effective Floor
Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
73 |
73 |
73 |
72 |
72 |
72 |
69 |
69 |
69 |
| 1 |
68 |
66 |
63 |
67 |
64 |
62 |
62 |
60 |
59 |
| 2 |
63 |
59 |
55 |
62 |
58 |
54 |
55 |
53 |
50 |
| 3 |
58 |
53 |
48 |
57 |
52 |
48 |
50 |
47 |
44 |
| 4 |
54 |
47 |
43 |
53 |
47 |
42 |
45 |
41 |
38 |
| 5 |
50 |
43 |
38 |
48 |
42 |
37 |
41 |
36 |
33 |
| 6 |
46 |
38 |
33 |
45 |
38 |
33 |
37 |
33 |
29 |
| 7 |
43 |
35 |
30 |
42 |
34 |
29 |
33 |
29 |
26 |
| 8 |
39 |
31 |
26 |
38 |
31 |
26 |
30 |
26 |
23 |
| 9 |
36 |
28 |
23 |
35 |
28 |
23 |
27 |
23 |
20 |
| 10 |
34 |
26 |
21 |
33 |
25 |
21 |
25 |
20 |
18 |
| Visual
Comfort Probability Table Average 100 FC, Reflectance 80/50/20 |
| Room
Size |
0°
Plane Ceiling Ht. |
90°
Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
65 |
69 |
64 |
67 |
| 30 |
30 |
58 |
62 |
57 |
60 |
| 30 |
60 |
49 |
52 |
49 |
51 |
| 60 |
30 |
61 |
64 |
60 |
63 |
| 60 |
60 |
51 |
53 |
50 |
52 |
| Average
Luminance (Footlamberts) |
| Vertical |
Horizontal
Plane |
| Angle |
0° |
90° |
| 45 |
1083. |
1310. |
| 55 |
865. |
1050. |
| 65 |
661. |
716. |
| 75 |
695. |
711. |
| 85 |
659. |
703. |
Catalog Number : RG2U222-OT1FARS
.095 Pattern 12 acrylic lens.
Lamps: Two FB031/35K Octron
Curvalume Each Rated 2800 Lumens.

Total Luminaire Efficiency = 70.5%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.3 |
| Shielding Angles: |
90 |
90 |
| Zonal
Lumen Summary |
| ZONE |
LUMENS |
%LAMP |
%FIXT |
| 0 - 30 |
1325 |
23.7 |
33.5 |
| 0 - 40 |
2145 |
38.3 |
54.3 |
| 0 - 50 |
3421 |
61.1 |
86.6 |
| 0 - 90 |
3951 |
70.5 |
100.0 |
Coefficients of Utilization - Zonal Cavity Method Effective
Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70 |
50 |
30 |
70 |
50 |
30 |
50 |
30 |
10 |
| 0 |
84 |
84 |
84 |
82 |
82 |
82 |
78 |
78 |
78 |
| 1 |
78 |
75 |
73 |
76 |
74 |
71 |
71 |
69 |
67 |
| 2 |
72 |
67 |
63 |
79 |
66 |
62 |
64 |
60 |
58 |
| 3 |
67 |
60 |
56 |
65 |
59 |
55 |
57 |
53 |
50 |
| 4 |
62 |
54 |
49 |
60 |
53 |
48 |
52 |
47 |
44 |
| 5 |
57 |
49 |
43 |
56 |
48 |
43 |
47 |
42 |
38 |
| 6 |
53 |
44 |
38 |
51 |
43 |
38 |
42 |
37 |
34 |
| 7 |
49 |
40 |
34 |
48 |
39 |
34 |
38 |
33 |
30 |
| 8 |
45 |
36 |
30 |
44 |
35 |
30 |
34 |
30 |
26 |
| 9 |
41 |
32 |
27 |
40 |
32 |
26 |
31 |
26 |
23 |
| 10 |
39 |
29 |
24 |
38 |
29 |
24 |
28 |
23 |
20 |
| Visual
Comfort Probability Table Average 100 FC, Reflectance 80/50/20 |
| Room
Size |
0°
Plane Ceiling Ht. |
90°
Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
63 |
67 |
62 |
65 |
| 30 |
30 |
56 |
60 |
55 |
58 |
| 30 |
60 |
47 |
50 |
46 |
49 |
| 60 |
30 |
59 |
62 |
58 |
61 |
| 60 |
60 |
49 |
51 |
48 |
50 |
| Average
Luminance (Footlamberts) |
| Vertical
Angle |
Horizontal
Plane |
| |
0° |
90° |
| 45 |
1163. |
1437. |
| 55 |
911. |
1099. |
| 65 |
714. |
762. |
| 75 |
744. |
763. |
| 85 |
714. |
781. |
Catalog Number : RG24T22-BH1FARS
.095 Pattern 12 acrylic lens.
Lamps: Two Biax F40BX/SPX35/RS

Each Rated 3150 Lumens.
Total Luminaire Efficiency = 71.4%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.2 |
1.4 |
| Shielding Angles: |
90 |
90 |
| Zonal
Lumen Summary |
| ZONE |
LUMENS |
%LAMP |
%FIXT |
| 0 - 30 |
1517 |
24.1 |
33.7 |
| 0 - 40 |
2457 |
39.0 |
54.6 |
| 0 - 50 |
3899 |
61.9 |
86.7 |
| 0 - 90 |
4497 |
71.4 |
100.0 |
Coefficients of Utilization - Zonal Cavity Method Effective
Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
85 |
85 |
85 |
83 |
83 |
83 |
79 |
79 |
79 |
| 1 |
79 |
76 |
73 |
77 |
74 |
72 |
71 |
70 |
68 |
| 2 |
73 |
68 |
64 |
71 |
67 |
63 |
64 |
61 |
58 |
| 3 |
68 |
61 |
56 |
66 |
60 |
55 |
58 |
54 |
51 |
| 4 |
63 |
55 |
50 |
61 |
54 |
49 |
52 |
48 |
44 |
| 5 |
58 |
49 |
44 |
56 |
49 |
43 |
47 |
42 |
39 |
| 6 |
53 |
45 |
39 |
52 |
44 |
39 |
43 |
38 |
34 |
| 7 |
49 |
40 |
35 |
48 |
40 |
34 |
39 |
34 |
30 |
| 8 |
46 |
36 |
31 |
44 |
36 |
30 |
35 |
30 |
26 |
| 9 |
42 |
33 |
27 |
41 |
32 |
27 |
32 |
27 |
23 |
| 10 |
39 |
30 |
24 |
38 |
29 |
24 |
29 |
24 |
20 |
| Visual
Comfort Probability Table Average 100 FC, Reflectance 80/50/20 |
| Room
Size |
0°
Plane Ceiling Ht. |
90°
Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
61 |
64 |
59 |
62 |
| 30 |
30 |
53 |
57 |
52 |
56 |
| 30 |
60 |
44 |
46 |
43 |
46 |
| 60 |
30 |
55 |
59 |
55 |
58 |
| 60 |
60 |
45 |
48 |
45 |
47 |
| Average
Luminance (Footlamberts) |
| Vertical |
Horizontal
Plane |
| Angle |
0° |
90° |
| 45 |
1329. |
1609. |
| 55 |
1043. |
1220. |
| 65 |
808. |
863. |
| 75 |
846. |
868. |
| 85 |
826. |
893. |
Catalog Number : RG34T22-bh1FARS
.095 Pattern 12 acrylic lens.
Lamps: Three Biax F40BX/SPX35/RS
Each Rated 3150 Lumens.

Total Luminaire Efficiency = 69.3%
| Plane : |
O-DEG |
90-DEG |
| Spacing Criteria : |
1.3 |
1.2 |
| Shielding Angles: |
90 |
90 |
| Zonal
Lumen Summary |
| ZONE |
LUMENS |
%LAMP |
%FIXT |
| 0 - 30 |
2275 |
24.1 |
34.8 |
| 0 - 40 |
3641 |
38.5 |
55.6 |
| 0 - 50 |
5690 |
60.2 |
86.9 |
| 0 - 90 |
6546 |
69.3 |
100.0 |
Coefficients of Utilization - Zonal Cavity Method Effective
Floor Cavity Reflectance 20% |
| RC |
80% |
70% |
50% |
| RW |
70% |
50% |
30% |
70% |
50% |
30% |
50% |
30% |
10% |
| 0 |
82 |
82 |
82 |
81 |
81 |
81 |
77 |
77 |
77 |
| 1 |
77 |
74 |
71 |
75 |
72 |
70 |
69 |
68 |
66 |
| 2 |
71 |
66 |
62 |
69 |
65 |
61 |
63 |
60 |
57 |
| 3 |
66 |
60 |
55 |
64 |
59 |
54 |
57 |
53 |
50 |
| 4 |
61 |
54 |
48 |
59 |
53 |
48 |
51 |
47 |
43 |
| 5 |
56 |
48 |
43 |
55 |
47 |
42 |
46 |
41 |
38 |
| 6 |
52 |
44 |
38 |
51 |
43 |
38 |
42 |
37 |
34 |
| 7 |
48 |
40 |
34 |
47 |
39 |
34 |
38 |
33 |
30 |
| 8 |
45 |
36 |
30 |
43 |
35 |
30 |
34 |
30 |
26 |
| 9 |
41 |
32 |
27 |
40 |
32 |
27 |
31 |
26 |
23 |
| 10 |
38 |
29 |
24 |
37 |
29 |
24 |
28 |
24 |
20 |
Visual
Comfort Probability Table Average 100 FC, Reflectance 80/50/20 |
| Room
Size |
0°
Plane Ceiling Ht. |
90°
Plane Ceiling Ht. |
| W |
L |
8.5 |
10.0 |
8.5 |
10.0 |
| 20 |
20 |
50 |
54 |
51 |
55 |
| 30 |
30 |
43 |
46 |
44 |
47 |
| 30 |
60 |
34 |
37 |
35 |
37 |
| 60 |
30 |
46 |
50 |
46 |
50 |
| 60 |
60 |
36 |
38 |
37 |
39 |
Average Luminance (Footlamberts) |
| Vertical |
Horizontal
Plane |
| Angle |
0° |
90° |
| 45 |
2221. |
1975. |
| 55 |
1722. |
1517. |
| 65 |
1216. |
1163. |
| 75 |
1256. |
1226. |
| 85 |
1239. |
1195. |
LUMAX INDUSTRIES, INC.
RG-2x2.697 |