| CL SERIES Corridor Lighting |

|
Catalog Number: CL13248 - EOISA
Lamp: One F32T8/CW Rated 2900 Lumens
| Zonal
Lumen Summary |
| ZONE |
LUMENS |
%LAMP |
%FIXT |
| 0 - 30 |
432 |
14.9 |
17.4 |
| 0 - 40 |
739 |
25.5 |
29.8 |
| 0 - 60 |
1324 |
45.7 |
53.4 |
| 0 - 90 |
1940 |
66.9 |
78.2 |

| Coefficients
of Utilization - Zonal Cavity Method Effective
Floor Cavity Reflectance 0.20 |
| RC |
80 |
70 |
50 |
30 |
10 |
0 |
| RW |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
10 |
50 |
30 |
10 |
50 |
30 |
10 |
50 |
30 |
10 |
0 |
| 0 |
97 |
97 |
97 |
97 |
93 |
93 |
93 |
93 |
85 |
85 |
85 |
77 |
77 |
77 |
70 |
70 |
70 |
67 |
| 1 |
87 |
82 |
78 |
74 |
82 |
78 |
74 |
71 |
71 |
68 |
65 |
64 |
62 |
60 |
58 |
57 |
55 |
52 |
| 2 |
78 |
71 |
64 |
59 |
74 |
68 |
62 |
57 |
61 |
57 |
53 |
56 |
52 |
49 |
51 |
48 |
45 |
42 |
| 3 |
72 |
62 |
55 |
49 |
68 |
59 |
53 |
48 |
54 |
49 |
44 |
49 |
45 |
41 |
45 |
41 |
38 |
36 |
| 4 |
66 |
55 |
47 |
42 |
62 |
53 |
46 |
40 |
48 |
42 |
38 |
44 |
39 |
35 |
40 |
36 |
33 |
30 |
| 5 |
60 |
49 |
41 |
35 |
57 |
47 |
40 |
34 |
43 |
37 |
32 |
39 |
34 |
30 |
36 |
31 |
28 |
26 |
| 6 |
55 |
44 |
36 |
30 |
52 |
42 |
35 |
29 |
38 |
32 |
28 |
35 |
30 |
26 |
32 |
28 |
24 |
22 |
| 7 |
51 |
39 |
32 |
26 |
48 |
38 |
31 |
26 |
35 |
28 |
24 |
32 |
27 |
23 |
29 |
25 |
21 |
19 |
| 8 |
47 |
35 |
28 |
23 |
44 |
34 |
27 |
22 |
31 |
25 |
21 |
28 |
23 |
20 |
26 |
22 |
18 |
16 |
| 9 |
43 |
31 |
24 |
20 |
41 |
30 |
24 |
19 |
28 |
22 |
18 |
26 |
20 |
17 |
23 |
19 |
16 |
14 |
| 10 |
40 |
29 |
22 |
17 |
38 |
27 |
21 |
17 |
25 |
20 |
16 |
23 |
18 |
15 |
21 |
17 |
14 |
12 |

* For 277 volt, substitute '4'
LAMPS:
BALLASTS:
| BE - 430 ma Rapid Start Energy Saving |
| ET - 430 ma Electronic |
| OT - 265 ma Magnetic Octron |
| EO - 265 ma Electronic Octron |
| CO - 265 ma Electronic Octron (3 or 4 lamp) |
NOTE : On 3 or 4 lamp electronic fixtures,
CO designates a single 3 or 4 lamp ballast in fixture. ET and EO
designate 2 ballasts in fixture, with inboard lamp(s) wired separately.
OPTIONS:
| Use the following suffix for : |
| -F1 Fusing, one per fixture |
| -F2 Fusing, one per ballast |
| -RF1 Radio Interference Filter, one per fixture |
| -RF2 Radio Inference Filter, one per ballast |
| -LD Housing Embossments for Low Density Ceilings |
Emergency Ballast - Please consult options
page for complete listings.
Dimming Ballasts - Please consult the
factory.
ACCESSORIES:
Continuous Row Mounting:
2304P Lens Joiner (replaces 2 end
plates)
Stem Mounting for 48" fixtures, order
(2 per fixture):
C96 Single Stem Canopy
S-(*) Pipe Stem - *specify length


specifications and dimensional data subject to change without notice

Lens hinges full length from either side of fixture
Note: 96" models use two 48" self-hinging lenses and
center white trim strip.
LUMAX INDUSTRIES, INC.
CL.697 |