   Metal Sales Mfg. Corp.  Metal Solutions  

Metal Solutions Page - 1

 

 

sol01c.JPG (5821 bytes)

  • Architectural/Structural Flat Pan Standing Seam Panel
  • 16" Panel Coverage
  • 2" Rib Height
  • Gauges:  24 GA Standard and 22 GA Optional
  • Minimum Roof Slope:  1/2 : 12
  • Factory Applied Side Lap Sealant
  • Integral Mechanically Seamed Side Lap, Seam Closed to 70 Degrees
  • Concealed Clip Designed to Accommodate 1/2" to 6" Blanket Insulation
  • Concealed Clip Designed to Accommodate Movement Due to Temperature Change
  • Applies Over Open Framing or Solid Substrate
  • Available Finishes Include Kynar 500 (PVF2), MS Colorfast 25® and Bare Galvalume™

Testing:

  1. UL 580, Class 90 Wind Uplift, Construction Number 90, and 238B
  2. UL 263 Fire Resistance Rating
  3. CEGS-07416 US Army Corps of Engineers Rated
  4. ASTM E-283 Air Infiltration Approved
  5. ASTM E-331 Water Penetration Approved

    sol01d.JPG (6461 bytes)

    sol01a.JPG (17005 bytes)

Allowable Uniform Loads for 3 or more Spans in PSF

 

Inward Load (Stress)

Inward Load (Deflection)

GA

Width

KSI

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

24

16

50

258.3

145.3

93

64.6

47.4

36.3

258.3

145.3

93

64.6

47.4

36.3

 

Outward Load (Stress)

Outward Load (Deflection)

GA

Width

KSI

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

24

16

50

220.7

124.1

79.4

55.2

40.5

31

220.7

124.1

79.4

55.2

40.5

31

Notes:

  1. Theoretical section properties computed for flexural loads per AISI Cold Formed Steel Design Manual 1986 Edition.
  2. Loads in tables based on continuous beam over three equal spans. For stress loads, 2-span load would be 0.80 of the 3-span load.
  3. Allowable loads have not been increased by 33 1/3% for wind uplift.
  4. Allowable loads for deflection based on deflection limitation of span/180.
  5. For root panels, self weight of the panel has to be deducted from the allowable inward load to arrive at the actual "live load" carrying capacity of the panel.

sol01e.JPG (6107 bytes)

  • Structural Trapezoidal Standing Seam Panel
  • 24" Panel Coverage
  • 2 11/16" Rib Height
  • Gauges: 24 GA Standard and 22 GA Optional
  • Minimum Roof Slope: 1/4 : 12
  • Factory Applied Side Lap Sealant
  • Pittsburgh Double Flat Locking Mechanically Seamed Side Lap
  • Concealed Clip Designed to Accommodate 1/2" to 6" Blanket Insulation
  • Concealed Clip Designed to Accommodate Movement Due to Temperature Change
  • Applies Over Open Framing or Solid Substrate
  • Available Finishes Include Kynar 500 (PVF2), MS Colorfast 25® and Bare Galvalume™

Testing:

  1. UL 580, Class 90 Wind Uplift, Construction Number 197
  2. UL 263 Fire Resistance Rating
  3. CEGS-07416 US Army Corps of Engineers Rated
  4. ASTM E-283 Air Infiltration Approved
  5. ASTM E-331 Water Penetration Approved

    sol01f.JPG (3101 bytes)

    sol01b.JPG (17232 bytes)

Allowable Uniform Loads for 3 or more Spans in PSF

 

Inward Load (Stress)

Inward Load (Deflection)

GA

Width

KSI

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

26

24

50

141.4

79.5

50.9

35.3

26

19.9

141.4

79.5

50.9

35.3

26

19.9

24

24

50

185.8

104.5

66.9

46.5

34.1

26.1

185.8

104.5

66.9

46.5

34.1

26.1

 

Outward Load (Stress)

Outward Load (Deflection)

GA

Width

KSI

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

26

24

50

158.0

88.9

56.9

39.5

29

22.2

158.0

88.9

56.9

39.5

29

22.2

24

24

50

206.8

116.3

74.4

51.7

38

29.1

206.8

116.3

74.4

51.7

38

29.1


Notes:

  1. Theoretical section properties computed for flexural loads per AISI Cold Formed Steel Design Manual 1986 Edition.
  2. Loads in tables based on continuous beam over three equal spans. For stress loads, 2-span load would be 0.80 of the 3-span load.
  3. Allowable loads have not been increased by 33 1/3% for wind uplift.
  4. Allowable loads for deflection based on deflection limitation of span/180.
  5. For roof panels, self weight of the panel has to be deducted from the allowable inward load to arrive at the actual "live load" carrying capacity of the panel.

 

Request for Information / Request a Catalog from Metal Sales Mfg. Corp.
 
 
 
To request more information from Metal Sales Mfg. Corp., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com