Homepage  
Search
find:
search for:
   
 
Site Navigation
News / Publications
Jobs
Service
   Add this page to Google Bookmarks
   Add this page to Mister Wong
   Add this page to del.icio.us
 
   Metal Sales Mfg. Corp.  Metal Solutions  

Metal Solutions Page - 2

 

 

sol02b.JPG (5817 bytes)

  • Architectural Structural Integral Standing Seam Panel
  • 10", 12", 16" and 18" Panel Coverage
  • 1 3/4" Rib Height
  • Gauges: 26 GA and 24 GA Standard, 22 GA Optional
  • Minimum Roof Slope:  3 : 12
  • Factory Applied Side Lap Sealant
  • Snap Together Panel System
  • Concealed Clip Designed to Accommodate 1/2" to 3" Blanket Insulation
  • Concealed Clip Designed to Accommodate Movement Due to Temperature Change
  • Applies Over Open Framing or Solid Substrate
  • Available Finishes Include Kynar 500 (PVF2),
  • MS Colorfast 25®, and Bare Galvalume™

Testing:

  1. UL 580, Class 90 Wind Uplift, Construction Number 255, 261, 303, 342, and 343
  2. UL 263 Fire Resistance Rating
  3. ASTM E-283 Air Infiltration Approved
  4. ASTM E-331 Water Penetration Approved
  5. Texas Windstorm Approved

    sol02c.JPG (7547 bytes)

    sol02a.JPG (14593 bytes)

Allowable Uniform Loads for 3 or more Spans in PSF

 

Inward Load (Stress)

Inward Load (Deflection)

GA

Width

KSI

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

24

18

50

92.9

52.3

33.4

23.2

17.1

13.1

92.9

52.3

33.4

23.2

17.1

13.1

24

16

50

104.5

58.8

37.6

26.1

19.2

14.7

104.7

58.8

37.6

26.1

19.2

14.7

24

12

50

139.1

78.3

50.1

34.8

25.6

19.6

139.1

78.3

50.1

34.8

25.6

19.6

24

10

50

168.5

94.8

60.7

42.1

30.9

23.7

168.5

94.8

60.7

42.1

30.9

23.7

 

Outward Load (Stress)

Outward Load (Deflection)

GA

Width

KSI

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

24

18

50

127.5

71.7

45.9

31.9

23.4

17.9

127.5

71.7

43.1

24.9

15.7

10.5

24

16

50

143.3

80.6

51.6

35.8

26.3

20.2

143.3

80.6

48.4

28

17.6

11.8

24

12

50

190.9

107.4

68.7

47.7

35.1

26.8

190.9

107.4

64.4

37.3

23.5

15.7

24

10

50

231.1

130

83.2

57.8

42.5

32.5

231.1

130

78

45.1

28.4

19


Notes:

  1. Theoretical section properties computed for flexural loads per AlSl Cold Formed Steel Design Manual 1986 Edition.
  2. Loads in tables based on continuous beam over three equal spans. For stress loads, 2-span load would be 0.80 of the 3-span load.
  3. Allowable loads have not been increased by 33 1/3% for wind uplift.
  4. Allowable loads for deflection based on deflection limitation of span/180.
  5. For roof panels, self weight of the panel has to be deducted from the allowable inward load to arrive at the actual "live load" carrying capacity of the panel.

 

Request for Information / Request a Catalog from Metal Sales Mfg. Corp.
 
 
 
To request more information from Metal Sales Mfg. Corp., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com